联系人:田正兴
联系电话:
公司座机:
英国凯恩KM945手持式烟气分析仪
应用:
·工业锅炉的安装、调试和服务
·商业石油,天然气或生物质设备安装、调试和服务
·安全检查--密闭空间及空气环境中的CO标检测
·燃烧排放检测
·燃烧效率检测
·烟道通风检测
|
·可用红外打印机打印数据 |
|
|
·CO测量浓度范围:0-4000PPM |
·可存储150组数据 |
|
(H2补偿功能) |
·长寿命电池 |
|
·压差测量 |
·大吸力双气口气泵 |
|
·烟气温度及温差测量 |
·标配探枪,导气软管 |
|
·计算二氧化碳CO2值 |
·内置多种可选择燃料类型 |
|
·计算CO/CO2比例 |
且支持用户自定仪燃料类型 |
|
·计算过量空气浓度 |
·一年质保 |
|
·计算燃烧效率 |
|
|
·另有两种气体可选配 |
|
标准配置:
·分析仪主机
·金恬探枪及软管
·充电器
·操作手册
·校准报告
·便携包
Specifications
|
参数 |
分辨率 |
精度 |
范围 |
|
|
|
|
|
|
|
|
烟气温度 |
1.0 F/C |
±2.0 F/C, ±0.3% of rdg |
32 - 1112 F |
|
|
|
|
(0 - 600 C) |
||
|
|
|
|
||
|
进气温度 |
0.1 F/C |
±1.0 F/C, ±0.3% of rdg |
32 - 122 F |
|
|
|
|
(0 - 50 C) |
||
|
|
|
|
||
|
压力 |
0.1 mbar |
±2% of full scale |
±150 mbar |
|
|
所能检测的气体 |
|
|
|
|
|
氧气O2 |
0.001 |
±0.2% |
0 |
- 21% |
|
一氧化碳CO |
1 ppm |
±20 ppm <400 ppm |
0 |
- 10,000 ppm |
|
(标准:带H2补偿功能) |
|
±5% >5000 ppm |
|
|
|
(可选) |
|
±10%<5000 ppm |
|
|
|
一氧化碳CO |
0.0001 |
±5% reading from |
0 |
~ 10% |
|
(高量程)(可选) |
|
0.1% to 10% |
|
|
|
一氧化氮NO |
1 ppm |
±5 ppm <100 ppm |
0 |
- 5000 ppm |
|
(标准)(可选) |
|
±5%>100 ppm |
|
|
|
一氧化氮NO |
1 ppm |
±2 ppm <30 ppm |
0 |
~ 100 ppm |
|
(低量程)(可选) |
|
±5 ppm <30 ppm |
|
|
|
二氧化氮NO2 |
1 ppm |
±5 ppm<100 ppm |
0 |
~ 1000 ppm |
|
(可选) |
|
±10 ppm<500 ppm |
|
|
|
|
±5%>500 ppm |
|
|
|
|
|
|
|
|
|
|
二氧化硫SO2 |
1 ppm |
±5 ppm<100 ppm |
0 |
~ 5000 ppm |
|
(可选) |
|
±5%>100 ppm |
|
|
|
计算值 |
|
|
|
|
|
二氧化碳CO2 |
0.001 |
±0.3% reading |
0 |
~ 99.9% |
|
损失 |
0.001 |
±1.0% reading |
0 |
~ 99.9% |
|
效率 |
0.001 |
±1.0% reading |
0 |
~ 99.9% |
|
过量空气 |
0.001 |
±0.2% |
0 |
~ 2885.0% |
|
温度(NETT) |
1.0 C/F |
±2 C ±0.3% reading |
32 ~ 1112 F |
|
|
|
|
|
(0 ~ 600 C) |
|
|
CO/CO2比例 |
0.0001 |
±0.0001 |
0 |
~ 0.9999 |
|
毒性指数 |
0.0001 |
±0.01 |
0 |
~ 99.99 |
|
可选择的燃料 |
Natural Gas, Town Gas, Gascor, Light Oil, Heavy Oil, |
|||
|
|
Propane,Butane, Anthrocite, Coke, Coal, Kinsale Gas |
|||
标准配置
|
尺寸及重量 |
重量 |
1 Kg |
|
|
长宽高 |
220 x 55 x 120 mm |
|
|
探枪 |
420MM长,8MM直径不锈钢探枪 |
|
|
手柄,K型热电偶及3M软管 |
|
|
操作环境 |
0 C to 45 C/10% to 90% RH non condensing |
|
|
电源 |
Input: 110V AC / 220V AC nominal |
|
|
充电器 |
Output: 12V AC off load |
|
|
电池寿命 |
充满电后可连续工作6小时以上 |
|
联系人:田正兴
联系电话:
公司座机:
邮箱地址:lb041015@loobo.cn
欢迎新老客户咨询订购,给我一份信任,还您十分满意!

British Kaine KM945 handheld flue gas analyzer
Application:
Installation, commissioning and service of industrial boilers
Installation, commissioning and service of commercial oil, natural gas or biomass equipment
Safety check - CO detection in confined space and air environment
Combustion emission detection
Combustion efficiency test
Flue ventilation test
* O2 measurement concentration range: 0-21% / IR printer print data
CO measurement concentration range: 0-4000PPM - can store 150 sets of data
(H2 compensation function) long life battery
- differential pressure measurement, large suction pump double tone
- flue gas temperature and the temperature measuring probe gun standard, gas hose
Calculate the CO2 value of CO2 and build a variety of alternative fuel types
Calculate CO/CO2 ratio and support user defined fuel type
Calculation of excess air concentration and one year warranty
Calculation of combustion efficiency
Another two gases can be selected
Standard configuration:
Analyzer host
Kim Tim probe gun and hose
Charger
Operation manual
Calibration report
Portable bag
Specifications
Parameter resolution accuracy range
Flue gas temperature 1 F/C + + F/C, + 0.3% RDG - 1112 of - 2 F
(0 - 600 C)
Inlet temperature 0.1 F/C + + F/C, + 0.3% RDG - 122 of - 1 F
(0 - 50 C)
Pressure 0.1 mbar + of full scale + + 150 mbar ()
Capable of detecting gases
Oxygen O2 0.001 + 0.2% 0 - 21%
Carbon monoxide CO 1 ppm + 20 <400 ppm - 0 - 10000 ppm (PPM)
(standard: with H2 compensation function) + 5% >5000 ppm
(optional) + 10%<5000 ppm
Carbon monoxide CO 0.0001 + reading from 0 ~ 5% ~ 10%
(Gao Liangcheng) (optional) 0.1% to
Nitric oxide NO 1 ppm + ppm <100 ppm - 0 - 5000 ppm ()
(standard) (optional) + 5%>100 ppm
Nitric oxide NO 1 ppm + ppm <30 0 ~ 2 ppm ~ 100 ppm
(Di Liangcheng) (optional) + 5 ppm <30 ppm
No2 NO2 1 ppm + 5 ppm<100 ppm 0 ~ 1000 ppm
(optional) + 10 ppm<500 ppm
+ 5%>500 ppm
Sulfur dioxide SO2 1 ppm + 5 ppm ppm<100 ~ 5000 ~ 0 ppm
(optional) + 5%>100 ppm
calculated value
Carbon dioxide CO2 0.001 + 0.3% reading ~ 0 ~ 99.9%
Loss 0.001 + reading 0 ~ 1% ~ 99.9%
Efficiency 0.001 + reading 0 ~ 1% ~ 99.9%
Excess air 0.001 + 0.2% ~ 0 ~ 2885%
Temperature (NETT) 1 C/F + + 2 C + 0.3% reading ~ 32 F ~ 1112
(0 ~ 600 C)
CO/CO2 ratio 0.0001 + 0.00010 ~ ~ 0.9999
Toxicity index 0.0001 + - 0.010 ~ ~ 99.99
Alternative fuel Natural Gas, Town Gas, Gascor, Light Oil, Heavy Oil,
Propane, Butane, Anthrocite, Coke, Coal, Kinsale Gas
Standard configuration
Size and weight 1 Kg
Length width height 220 x 55 x 120 mm
Probe 420MM long, 8MM diameter stainless steel probe
Handle, K type thermocouple and 3M hose
Operating environment 0 C to to C/10% RH 90% non condensing
Power Input: 110V AC / 220V AC nominal
Charger Output: 12V off AC load
Battery life can work continuously for more than 6 hours