型号及参数
Model Adjustable Set Point Range Deadband Over Range Proof
Low end of range on fall; Pressure* Pressure**
High end of range on rise
“wc mbar “wc mbar psi bar psi bar
Type H100
Buna N diaphragm and O-Ring with epoxy coated aluminum 1/2” NPT (female) pressure connection, large 0.72” orifice for clean-out
purposes (other wetted materials available see page 11)
520 300 Vac to 0 -746,7 to 0 0.2 to 8 0,5 to 19,9 200 13,8 400 27,6
521 10 Vac to 10 -24,9 to 24,9 0.1 to 0.6 0,2 to 1,5 200 13,8 400 27,6
522 50 Vac to 50 -124,5 to 124,5 0.1 to 3 0,2 to 7,5 200 13,8 400 27,6
523 0.5 to 5.0 1,2 to 12,4 0.1 to 0.3 0,2 to 0,7 200 13,8 400 27,6
524 2.5 to 50 6,2 to 124,5 0.1 to 0.8 0,2 to 2,0 200 13,8 400 27,6
525 10 to 250 24,9 to 622,3 0.1 to 6 0,2 to 14,9 200 13,8 400 27,6
工作原理
压力开关的工作原理:是当系统内压力高于或低于额定的安全压力时,感应器内碟片瞬时发生移动,通过连接导杆推动开关接头接通或断开,当压力降至或升额定的恢复值时,碟片瞬时复位,开关自动复位,或者简单的说是当被测压力过额定值时,弹性元件的自由端产生位移,直接或经过比较后推动开关元件,改变开关元件的通断状态,达到控制被测压力的目的。压力开关采用的弹性元件有单圈弹簧管、膜片、膜盒及波纹管等。
应用注意事项
通常用到3类UE开关
1. 燃油管道输送燃油压力低,设定值通常为2Mpa左右。型号H100-193
2. 炉膛正负压力控制,设定值±1.5kpa左右。型号H100-521
3. 焦炉煤气管道压力低,设定值2kpa下报,型号J120-521或451.对开关死区要求不严格,因为报警后管道压力会归零,不需要开关反复重复动作。且小感压孔经验告诉我们使用起来没大问题。