J120K-541压力范围
型号 可调整设定范围 死区 工作压力 耐压**
上升时为设定点范围高压端
下降时为设定点范围低压端
H100K 型 psid bar psi bar psi bar psi bar
540 0.2 to 7 “wcd 0,5 to 17,4 mbar 0.05 to 0.6 “wc 0,1 to 1,5 mbar 30 “Hg Vac to 200 -1 to 13,8 400 27,6
541 1 to 20 “wcd 2,5 to 49,8 mbar 0.1 to 1.0 “wc 0,2 to 2,5 mbar 30 “Hg Vac to 200 -1 to 13,8 400 27,6
542 5 to 50 “wcd 12,4 to 124,5 mbar 0.2 to 2.5 “wc 0,5 to 6,2 mbar 30 “Hg Vac to 200 -1 to 13,8 400 27,6
543 10 to 200 “wcd 24,9 to 497,8 mbar 0.5 to 8 “wc 1,2 to 19,9 mbar 30 “Hg Vac to 200 -1 to 13,8 400 27,6
544 2 to 20 0,1 to 1,4 0.1 to 1.3 6,9 to 89,6 mbar 30 “Hg Vac to 1200 -1 to 82,7 2500 172,4
545 5 to 50 0,3 to 3,4 0.2 to 2.2 13,8 mbar to 0,1 30 “Hg Vac to 1200 -1 to 82,7 2500 172,4
546 10 to 125 0,7 to 8,6 0.4 to 5.0 27,6 mbar to 0,3 30 “Hg Vac to 1200 -1 to 82,7 2500 172,4
547 50 to 250 3,4 to 17,2 0.8 to 10 0,1 to 0,7 30 “Hg Vac to 1200 -1 to 82,7 2500 172,4
548 100 to 500 6,9 to 34,5 2. 0 to 15 0,1 to 1,0 30 “Hg Vac to 1200 -1 to 82,7 2500 172,4
防爆压力开关的技术参数
1. 测量介质:对丁腈橡胶或316L不锈钢无腐蚀性的气体或液体
2. 外壳:压铸铝,环氧树脂涂层,带密封垫圈的外盖
3. 外壳等级:符合NEMA 4X要求
4. 设定点精度:±1%
5. 切换差:分为可调和不可调两种(参考选型表数据)
6. 重复性误差:<1%
7. 压力接口:标准1/2NPTF内螺纹;可根据现场需要,特殊订制
8. 电气接口:1/2″NPTF螺纹接口,可根据现场需要,特殊订制
9. 开关输出:一个单刀双掷(SPDT)输出;可在调整范围内进行分别设定;开关可接“常开型”或“常闭型”