HS-V510U消防电源双路三相监控模块斯沃电工

发布时间:2021-04-12

|HS-V510U-内容提要(Synopsis)

******销售   189  、6369、7816****** 

HS-V510U消防电源双路三相监控模块消防设备电源中继器能与消防用电现场的各种智能信号传感器进行通信连接和通信数据的采集与转发,并给现场信号传感器提供24V直流供电电源,将采集的数据转发给消防设备电源状态监控器,从而实现对各用电现场消防设备电源隐患的实时监控和实时反馈,消防电源监控系统,主要针对消防设备的电源的各项参数进行实时监控,

HS-V510U消防电源双路三相监控模块斯沃电工

 

|HS-V510U细节描述(Detailed deion)
·程序为我公司独立开发,可以根据客户的需求予以定制特殊的功能;
·继电器采用的是国内,使用寿命比常规的要好的多;继电器正常的在六万次以上,其他在七千次左右;
·所有出厂的产品都有刷三防漆,防水、防潮、防腐方面都要好;核心件都是进口件。

·The program is independently developed by our company, and special functions can be customized according to the needs of customers;

·The relay adopts domestic famous brands, and its service life is much better than that of the conventional ones; the normal relay is more than 60000 times, and other brands are about 7000 times;

·All factory products are painted with three proofing paints, which are better in waterproof, moisture-proof and anti-corrosion aspects; the core parts are imported ones.


|
HS-V510U消防电源双路三相监控模块

■ HS-V510U监测功能:监测消防电源电压、电流异常状态:主、备电源的过压、欠压、过流、错相、缺相、供电中断等故障状态
■ 统计功能:统计故障信息,形成SOE记录
■ 故障/报警功能:灯光报警
■ 通讯功能:通过智能通讯总线,将信息以数字化的形式进行远程传输,具有高度抗干扰能力
■ 其它功能:自检重要元器件;存储64条报警和故障记录,掉电后可保存10年

■ HS-V510Umonitoring function: monitoring the abnormal state of fire power supply voltage and current: overvoltage, undervoltage, overcurrent, wrong phase, missing phase, power supply interruption and other fault states of main and standby power supply
■Statistics function: Statistics fault information and form SOE record
■Fault / alarm function: light alarm
■Communication function: remote transmission of information in digital form through intelligent communication bus, with high anti-interference ability
■Other functions: self check important components; store 64 alarm and fault records, which can be sed for 10 years after power failure

 

|HS-V510U产品图片(Product picture)

HS-V510U消防电源双路三相监控模块斯沃电工

 

|HS-V510U技术指标(Technical index)
HS-V510U供电电压 DC24V由监控器或区域分机集中供电
额定功率 <0.5W
总线通信方式 CAN总线
通信线+电源线要求 NH-RVS2*1.5mm2(通信线)+NH-BV2*2.5mm2(电源线)
输出参数 1路无源触点,报警或控制输出
地址编码 每台传感器均具有地址编码
测量范围  AC20~500V DC10~30V AC0~1000A DC0~100A
隔离器         每台传感器内自带隔离器
报警参数 过压>额定电压的110%,欠压<额定电压的85%,电流报警值现场设定
报警显示 LED指示
报警延时 0~60S连续可调,现场可设定
环境温度  -20℃~+70℃
环境湿度 相对湿度≤95%
海拔高度 <4500m
防护等级 IP30
外形尺寸 110mm*85mm*45mm(长*宽*高)
安装方式 标准35mm导轨式安装

The power supply voltage is ﹥ DC24 V, which is supplied by the monitor or regional extension
Rated power < 0.5W
Bus communication mode: can bus
Communication line + power line: nh-rvs2 * 1.5mm2 (communication line) + nh-bv2 * 2.5mm2 (power line)
Output parameter: 1-way passive contact, alarm or control output
Address code each sensor has a unique address code
Measuring range: ac20 ~ 500V, DC10 ~ 30V, ac0 ~ 1000A, dc0 ~ 100A
Isolator each sensor has its own isolator
Alarm parameters: overvoltage > 110% of rated voltage, undervoltage < 85% of rated voltage, current alarm value is set on site
Alarm display LED indication
The alarm delay can be adjusted continuously from 0 to 60s, and can be set on site
Ambient temperature - 20 ℃~ + 70 ℃
Ambient humidity: > relative humidity ≤ 95%
Altitude < 4500m
The protection level is less than IP30
Overall dimension: 110mm * 85mm * 45mm (L * w * h)
Installation method: Standard 35mm rail installation

【内部随机图片】

 


|HS-V510U安装注意事项(Installation precautions)
先检查接入监控设备的各种连线规格是否满足要求,连线之间是否有短路现象;  依次将其它回路与监控器相连接,重复调试。产品安装,拆装和配线作业以及维护检查时务必断开电源连接线,注意触电和损害设备;

 

|HS-V510U试验设备(Test equipment)
每一个设备出厂前都会经过一整套完整的试验流程以保证它的品质:
--Step 1--静电放电发生器
--Step 2--多功能抗干扰测试
--Step 3--可程式恒温湿试验机
--Step 4--老温老化房
--Step 5--初校验台
--Step 6--复校验台
--Step 7--电能走字台

 Every equipment will go through a complete set of test process before leing the factory to ensure its quality
--Step 1 -- electrostatic discharge generator
--Step 2 -- multi function anti interference test
--Step 3 -- programmable constant temperature and humidity testing machine
--Step 4 -- aging room
--Step 5 -- preliminary calibration platform
--Step 6 -- recheck bench
--Step 7 -- electric energy walking platform

 

 |HS-V510U相关电工知识(Relevant electrical knowledge)

  求功率的公式为...电线能承受的电流受哪些因素影响对于我们时常计算电线承受的电流的算法,一般只是估算,真正可以反映出一根电线能承受的电流的数值,是在电线上标注的额定电流,这个数值才是比较准确的,而且是经过试验的出来的,但是在我们使用的每个型号...星形接法与三角形接法图及同一种电压不。  ,杆塔及电缆费用:改造工程费用列支,农网改造项目是由发改委统一立项,共同承担工程费用,主要是对年久失修,供电半径长,线路、杆塔、变压器等进行改造,以满足区域供电需求。第二,电能表及安装费用:电能表分两种情况,工程列支费用购置,成本列支,但之不需要用户承担。  公司在国有企业中一直是前三的位置,作为业务覆盖26省及自治区,其公司员工更是多达百万。所以,公司都会进行大规模的招聘。而统一校园招聘是重点的人才招收方式,一年两批分开进行,批在11月中旬,第二批在3月上旬。 

 

|团队实力(Team strength)
我们专注于中低压电气元器件的开发和生产,具备一支10年行业经验的优良产品研发团队。
一、研发团队
公司每年将营业收入的10%投入到研发和技术创新方面,以确保优先一步的技术与产品
二、技术团队
*的维保和售后技术已解决您的后顾之忧
三、销售团队
定期组织员工进行*知识培训以及现场实勘

We focus on the development and production of medium and low voltage electrical components, and he an excellent product R & D team with 10 years of industry experience.
1、 R & D team
Every year, the company invests 10% of its revenue into R & D and technological innovation to ensure the priority of technology and products
2、 Technical team
Professional maintenance and after-sales technology has solved your worries
3、 Sales team
Regularly organize staff to carry out professional knowledge training and field survey

 

========HS-V510U消防电源双路三相监控模块斯沃电工南京斯沃为您服务!=========

========HS-V510U消防电源双路三相监控模块斯沃电工南京斯沃为您服务!=========

 

上一篇:睢阳厂房竣工验收检测报告中心
下一篇:湛江钢纤维-厂直销批发