******销售 189 、6369、7816******
SPNFPE--ST消防电源监控模块怎么接线图消防设备电源状态监控器是根据*标准GB 58184-2011,研究开发的专门用于对消防设备的电源进行实时的监控,通过传感器对消防设备的主电源和备电源进行实时检测,从而判断电源设备是否过压、欠压、过流、短路、短路以及缺相等故障,系统适用于智能楼宇、高层公寓、宾馆、饭店、商厦、工矿企业、*消防单位以及石油化工]文教卫生、金融、电信等领域,符合GB 28184-2011《消防设备电源监控系统》及GB 25506-1010《消防控制室通用技术要求》的标准;
|SPNFPE--ST细节描述(Detailed de
·程序为我公司独立开发,可以根据客户的需求予以定制特殊的功能;
·继电器采用的是国内,使用寿命比常规的要好的多;继电器正常的在六万次以上,其他在七千次左右;
·所有出厂的产品都有刷三防漆,防水、防潮、防腐方面都要好;核心件都是进口件。
·The program is independently developed by our company, and special functions can be customized according to the needs of customers;
·The relay adopts domestic famous brands, and its service life is much better than that of the conventional ones; the normal relay is more than 60000 times, and other brands are about 7000 times;
·All factory products are painted with three proofing paints, which are better in waterproof, moisture-proof and anti-corrosion aspects; the core parts are imported ones.
|SPNFPE--ST消防电源监控模块怎么接线图
■ SPNFPE--ST监测功能:监测消防电源电压、电流异常状态:主、备电源的过压、欠压、过流、错相、缺相、供电中断等故障状态
■ 统计功能:统计故障信息,形成SOE记录
■ 故障/报警功能:灯光报警
■ 通讯功能:通过智能通讯总线,将信息以数字化的形式进行远程传输,具有高度抗干扰能力
■ 其它功能:自检重要元器件;存储64条报警和故障记录,掉电后可保存10年
■ SPNFPE--STmonitoring function: monitoring the abnormal state of fire power supply voltage and current: overvoltage, undervoltage, overcurrent, wrong phase, missing phase, power supply interruption and other fault states of main and standby power supply
■Statistics function: Statistics fault information and form SOE record
■Fault / alarm function: light alarm
■Communication function: remote transmission of information in digital form through intelligent communication bus, with high anti-interference ability
■Other functions: self check important components; store 64 alarm and fault records, which can be sed for 10 years after power failure
|SPNFPE--ST产品图片(Product picture)
|SPNFPE--ST技术指标(Technical index)
SPNFPE--ST供电电压 DC24V由监控器或区域分机集中供电
额定功率 <0.5W
总线通信方式 CAN总线
通信线+电源线要求 NH-RVS2*1.5mm2(通信线)+NH-BV2*2.5mm2(电源线)
输出参数 1路无源触点,报警或控制输出
地址编码 每台传感器均具有地址编码
测量范围 AC20~500V DC10~30V AC0~1000A DC0~100A
隔离器 每台传感器内自带隔离器
报警参数 过压>额定电压的110%,欠压<额定电压的85%,电流报警值现场设定
报警显示 LED指示
报警延时 0~60S连续可调,现场可设定
环境温度 -20℃~+70℃
环境湿度 相对湿度≤95%
海拔高度 <4500m
防护等级 IP30
外形尺寸 110mm*85mm*45mm(长*宽*高)
安装方式 标准35mm导轨式安装
The power supply voltage is ﹥ DC24 V, which is supplied by the monitor or regional extension
Rated power < 0.5W
Bus communication mode: can bus
Communication line + power line: nh-rvs2 * 1.5mm2 (communication line) + nh-bv2 * 2.5mm2 (power line)
Output parameter: 1-way passive contact, alarm or control output
Address code each sensor has a unique address code
Measuring range: ac20 ~ 500V, DC10 ~ 30V, ac0 ~ 1000A, dc0 ~ 100A
Isolator each sensor has its own isolator
Alarm parameters: overvoltage > 110% of rated voltage, undervoltage < 85% of rated voltage, current alarm value is set on site
Alarm display LED indication
The alarm delay can be adjusted continuously from 0 to 60s, and can be set on site
Ambient temperature - 20 ℃~ + 70 ℃
Ambient humidity: > relative humidity ≤ 95%
Altitude < 4500m
The protection level is less than IP30
Overall dimension: 110mm * 85mm * 45mm (L * w * h)
Installation method: Standard 35mm rail installation
【内部随机图片】
|SPNFPE--ST安装注意事项(Installation precautions)
观察监控器显示所监控的电源的实时工作状态信息,记录监控器的工作状态; 观察并记录所监控的电源的实时工作状态信息; 系统中敷设的通信总线应当满足建筑物本身划分的耐火等级线缆;总线敷设应考虑线路的压降损耗,现场测量压降,合理使用中继器扩展,不得随意搭接。
|SPNFPE--ST试验设备(Test equipment)
每一个设备出厂前都会经过一整套完整的试验流程以保证它的品质:
--Step 1--静电放电发生器
--Step 2--多功能抗干扰测试
--Step 3--可程式恒温湿试验机
--Step 4--老温老化房
--Step 5--初校验台
--Step 6--复校验台
--Step 7--电能走字台
Every equipment will go through a complete set of test process before leing the factory to ensure its quality
--Step 1 -- electrostatic discharge generator
--Step 2 -- multi function anti interference test
--Step 3 -- programmable constant temperature and humidity testing machine
--Step 4 -- aging room
--Step 5 -- preliminary calibration platform
--Step 6 -- recheck bench
--Step 7 -- electric energy walking platform
|SPNFPE--ST相关电工知识(Relevant electrical knowledge)
电工技术基础单相异步电动机如何更改运行方单相电动机正反转控制接法看下图:这个有的是可以更改的,有的是不可以更改的,电机的启动绕组和运行绕组相同时,可以改变电机的运行方向,如果不同,就不可以,只有重新换线,绕组相同时可以按下图改变运行方向...。 三相三线制和三相四线制的特点_三相三线制什么是三相三线制供电?什么是三相四线制供电?三相三线制是三相交流电源的一种连接方式,从3个线圈的端头引出3根导线,另将3个线圈尾端连在一起,又叫星形接线,常用符号Y表示,这种引出3根导线供电的方式叫三相三线制。 声控开关的原理如下市电220V交流电电压经过整流后经过220k的电阻降压,电容滤波,其中图中的5V稳压管稳压给4069供工作电压。声控开关在白天的时候,图中的2CU由于受到光照呈现低电态,因此13脚为低电平,不受声音控制,第8脚也为低电平。 据上海市科技成果转化促进会的相关工作人员介绍,待机节电器插在电源插座和家电插头之间,可以对遥控关机信号进行检测,当各类带有红外线遥控器控制的家用电器开启后又停用时,家电待机节电器就开始工作,从而大幅度降低待机能耗。 插一句,我在我们局的各个变电站看见,继保装置中,许继和南瑞的产品非常多,前者主要是传统的机电式继电器,后者主要是微机保护装置,看来他们的市场都不小。记得去年深圳南瑞来EE招聘时,去参加的硕硕有三十多个,本本只有寥寥几个,实际上是本本们不了解南瑞所致。
|团队实力(Team strength)
我们专注于中低压电气元器件的开发和生产,具备一支10年行业经验的优良产品研发团队。
一、研发团队
公司每年将营业收入的10%投入到研发和技术创新方面,以确保优先一步的技术与产品
二、技术团队
*的维保和售后技术已解决您的后顾之忧
三、销售团队
定期组织员工进行*知识培训以及现场实勘
We focus on the development and production of medium and low voltage electrical components, and he an excellent product R & D team with 10 years of industry experience.
1、 R & D team
Every year, the company invests 10% of its revenue into R & D and technological innovation to ensure the priority of technology and products
2、 Technical team
Professional maintenance and after-sales technology has solved your worries
3、 Sales team
Regularly organize staff to carry out professional knowledge training and field survey
========SPNFPE--ST消防电源监控模块怎么接线图斯沃电工南京斯沃为您服务!=========
========SPNFPE--ST消防电源监控模块怎么接线图斯沃电工南京斯沃为您服务!=========