AFPM3-AV电压信号传感器系统斯沃电工

发布时间:2021-04-12

|AFPM3--内容提要(Synopsis)

******销售   189  、6369、7816****** 

AFPM3-电压信号传感器系统系统适用于大型商场酒店、公共建筑、智能楼宇、石油化工、工矿企业等等领域;消防设备电源监控系统通过实时监测消防设备的电源状态,实时反映出被监控设备电源的状况,并集中显示,从而可以有效避免在火灾发生时,消防设备由于电源故障而无法正常工作的危急情况,大限度的保障消防联动系统的可靠性,

AFPM3-电压信号传感器系统斯沃电工

 

|AFPM3-细节描述(Detailed deion)
·程序为我公司独立开发,可以根据客户的需求予以定制特殊的功能;
·继电器采用的是国内,使用寿命比常规的要好的多;继电器正常的在六万次以上,其他在七千次左右;
·所有出厂的产品都有刷三防漆,防水、防潮、防腐方面都要好;核心件都是进口件。

·The program is independently developed by our company, and special functions can be customized according to the needs of customers;

·The relay adopts domestic famous brands, and its service life is much better than that of the conventional ones; the normal relay is more than 60000 times, and other brands are about 7000 times;

·All factory products are painted with three proofing paints, which are better in waterproof, moisture-proof and anti-corrosion aspects; the core parts are imported ones.


|
AFPM3-电压信号传感器系统

■ AFPM3-监测功能:监测消防电源电压、电流异常状态:主、备电源的过压、欠压、过流、错相、缺相、供电中断等故障状态
■ 统计功能:统计故障信息,形成SOE记录
■ 故障/报警功能:灯光报警
■ 通讯功能:通过智能通讯总线,将信息以数字化的形式进行远程传输,具有高度抗干扰能力
■ 其它功能:自检重要元器件;存储64条报警和故障记录,掉电后可保存10年

■ AFPM3-monitoring function: monitoring the abnormal state of fire power supply voltage and current: overvoltage, undervoltage, overcurrent, wrong phase, missing phase, power supply interruption and other fault states of main and standby power supply
■Statistics function: Statistics fault information and form SOE record
■Fault / alarm function: light alarm
■Communication function: remote transmission of information in digital form through intelligent communication bus, with high anti-interference ability
■Other functions: self check important components; store 64 alarm and fault records, which can be sed for 10 years after power failure

 

|AFPM3-产品图片(Product picture)

AFPM3-电压信号传感器系统斯沃电工

 

|AFPM3-技术指标(Technical index)
AFPM3-供电电压 DC24V由监控器或区域分机集中供电
额定功率 <0.5W
总线通信方式 CAN总线
通信线+电源线要求 NH-RVS2*1.5mm2(通信线)+NH-BV2*2.5mm2(电源线)
输出参数 1路无源触点,报警或控制输出
地址编码 每台传感器均具有地址编码
测量范围  AC20~500V DC10~30V AC0~1000A DC0~100A
隔离器         每台传感器内自带隔离器
报警参数 过压>额定电压的110%,欠压<额定电压的85%,电流报警值现场设定
报警显示 LED指示
报警延时 0~60S连续可调,现场可设定
环境温度  -20℃~+70℃
环境湿度 相对湿度≤95%
海拔高度 <4500m
防护等级 IP30
外形尺寸 110mm*85mm*45mm(长*宽*高)
安装方式 标准35mm导轨式安装

The power supply voltage is ﹥ DC24 V, which is supplied by the monitor or regional extension
Rated power < 0.5W
Bus communication mode: can bus
Communication line + power line: nh-rvs2 * 1.5mm2 (communication line) + nh-bv2 * 2.5mm2 (power line)
Output parameter: 1-way passive contact, alarm or control output
Address code each sensor has a unique address code
Measuring range: ac20 ~ 500V, DC10 ~ 30V, ac0 ~ 1000A, dc0 ~ 100A
Isolator each sensor has its own isolator
Alarm parameters: overvoltage > 110% of rated voltage, undervoltage < 85% of rated voltage, current alarm value is set on site
Alarm display LED indication
The alarm delay can be adjusted continuously from 0 to 60s, and can be set on site
Ambient temperature - 20 ℃~ + 70 ℃
Ambient humidity: > relative humidity ≤ 95%
Altitude < 4500m
The protection level is less than IP30
Overall dimension: 110mm * 85mm * 45mm (L * w * h)
Installation method: Standard 35mm rail installation

【内部随机图片】

 


|AFPM3-安装注意事项(Installation precautions)
监控器的主电源引入线严禁使用电源插头,应直接与消防电源连接;主电源应有明显的*标志。  将监控器与外部的连线断开,并将任一回路的传感器与之连接,其他回路可分别连接等效负载,接通电源,使监控器处于正常监视状态。当不具备单独安装条件时,传感器亦可安装在配电箱内,但不能对供电主回路产生影响。应尽量保持一定距离,并有明显标志。 

 

|AFPM3-试验设备(Test equipment)
每一个设备出厂前都会经过一整套完整的试验流程以保证它的品质:
--Step 1--静电放电发生器
--Step 2--多功能抗干扰测试
--Step 3--可程式恒温湿试验机
--Step 4--老温老化房
--Step 5--初校验台
--Step 6--复校验台
--Step 7--电能走字台

 Every equipment will go through a complete set of test process before leing the factory to ensure its quality
--Step 1 -- electrostatic discharge generator
--Step 2 -- multi function anti interference test
--Step 3 -- programmable constant temperature and humidity testing machine
--Step 4 -- aging room
--Step 5 -- preliminary calibration platform
--Step 6 -- recheck bench
--Step 7 -- electric energy walking platform

 

 |AFPM3-相关电工知识(Relevant electrical knowledge)

  华北电力大学在此榜单中由去年的第10跃居第6,此外,在2017年底教育部学位与研究生教育发展中心公布第四轮电气学科评估结果中,除了清华大学、西安交通大学为A+等级外,华北电力大学和华中科技大学同被评为,居前4。  就是达...电工如何带电操作及安全注意事项作为电工会经常遇见,有些设备也必须带电才能判断出故障点,有些设备停电会给其它用电单位带来巨大的经济损失或其它方面的损失;所以综上所述作为电工必须掌握带电作业的技能和安全措施,带电作业又分三类。  不过话又说回来,我们说...这主要取决于线路配电箱内的出线方式:是分路单独供电还是插座照明混在一起供电。是否采用漏电保护装置。下面针对这几种情况来说一下零线共用问题。所以,单从功能上来说,不管从哪一根电源线来说和零线之间的电位差都是...。  说实话,没有任何工具,要想分清零火线,只有靠颜色来做判断了。如果线的颜色都一样,那根本就无从下手,如果是三相5线的,那就更麻烦了。在没有任何工具,而且线的颜色又是一样的情况下,我们只能依靠借助用电器来做判断。 

 

|团队实力(Team strength)
我们专注于中低压电气元器件的开发和生产,具备一支10年行业经验的优良产品研发团队。
一、研发团队
公司每年将营业收入的10%投入到研发和技术创新方面,以确保优先一步的技术与产品
二、技术团队
*的维保和售后技术已解决您的后顾之忧
三、销售团队
定期组织员工进行*知识培训以及现场实勘

We focus on the development and production of medium and low voltage electrical components, and he an excellent product R & D team with 10 years of industry experience.
1、 R & D team
Every year, the company invests 10% of its revenue into R & D and technological innovation to ensure the priority of technology and products
2、 Technical team
Professional maintenance and after-sales technology has solved your worries
3、 Sales team
Regularly organize staff to carry out professional knowledge training and field survey

 

========AFPM3-电压信号传感器系统斯沃电工南京斯沃为您服务!=========