B72G-2GK-QD3-RMN诺冠过滤减压阀

英国norgren过滤减压阀型号
NORGREN诺冠 B72G-2AK-AL1-RMN
NORGREN诺冠 B72G-2AK-SD1-RMG
NORGREN诺冠 B72G-2AK-SD1-RMN
NORGREN诺冠 B72G-2AK-SD3-RMN
NORGREN诺冠 B72G-2AK-AL3-RCG
NORGREN诺冠 B72G-2AK-QD3-RFN
NORGREN诺冠 B72G-3AK-QT3-RMN
NORGREN诺冠 B72G-3AK-QW3-RMG
NORGREN诺冠 B72G-3AK-SD3-RMN
B68G-NNK-AR3-RLN
B68G-NNK-MR3-RLN
B73G-2GK-AT3-RMN
B73G-3GK-AP3-RMN
B74G-4GK-AP3-RMN
B72G-2GK-QD3-RMN
B72G-2GK-QT3-RMN
B72G-2GK-SD3-RMN
B72G-3BK-QT3-RMN
B73G-2GK-AD3-RMN
B73G-2GK-AT3-RMN
NORGREN诺冠 B72G-3AK-ST3-RMG
NORGREN诺冠 B72G-3BK-AL1-RMN
NORGREN诺冠 B72G-2AK-QD3-RMG
NORGREN诺冠 B72G-2AK-QD3-RMN
NORGREN诺冠 B72G-2AK-QM3-RMN
NORGREN诺冠 B72G-2AK-QT3-RMN
NORGREN诺冠 B72G-2AK-QW1-RMN
NORGREN诺冠 B72G-2AK-QW2-RMG
NORGREN诺冠 B72G-2AK-QW3-RMN
NORGREN诺冠 B72G-2AK-AL3-RMN
NORGREN诺冠 B72G-2AK-QD1-RFN
NORGREN诺冠 B72G-2AK-QD1-RMN
NORGREN诺冠 B72G-2AK-QD2-RMN
诺冠气动产品小知识:
1.诺冠比例阀正确安装方法汲步骤:
一、安装前检 工作,每台诺冠NORGREN比例阀(包括其旗下的海隆HERION比例阀、宝硕
BUSCHJOST比例阀、MAXSEAL比例阀)都会有明确铭牌,标注出相关的信息,在安装前务必要检查铭牌 上的型号、励、电
压、频率和应用是否正确。比例阀不能用于不相容的介质或者在过其额定压力值的工况下使用。
二、位置固定,除非特别指出,
比例阀安装在任意位置都可以正常工作。然而,为了优化使用性能和寿命,比例阀应该竖直向.上安装,以避免异物积聚在比例阀.
阀芯组件部位。
三、气路配管,根据阀体上的标记连接阀i ]管路系统。只需在管子的外螺纹上缠绕适量密封生料带。如果在比例
阀的内螺纹上使用生料,生料可能会进入阀中并造成运行困难。通过正确支撑和布管来避免发生管道变形。在紧固管道时,不要
使用阀i ]或比例阀作为杠杆。扳手在阀体或者管路上的施力位置应该尽可能靠近接头。要点:为保护比例阀,在尽可能靠近阀门
的入口侧安装适宜的过滤网或者过滤器。根据运行条件定期清洗。警告:为防止可能发生的人身伤害或者财产损失,在对比例阀
进行维护前,必须切断电源、将阀[ ]减压,并将流体排放到安全区域。意:修理时不需要将阀门从管道上卸下。
为了操作和维护方便,该阀一般直立安装在水平管道 上。安装时应注意 使管路中介质的流向与阀休上所示箭头的方
向*。为了防止阀后压力压,应在离阀出口不少于4M处安装一个安全阀。
减压阀工作原理.减压阀使用方法
用时通过减压阀使气体压力降至实验所需范围,再经过其它控制阀[门细调,使气体输入使用系统。总线常用的减压阀为
氧气减压阀,简称氧气表。
工作原理
氧气减压阀的高压腔与钢瓶连接,低压腔为气体出口,并通往使用系统。高压表的示值为钢瓶内贮存气体的压力。
低压表的出口压力可由调节螺杆控制。