一、耐电痕化指数测试仪技术参数
符合标准:GB 4706.1-2008、GB 4207-2012、IEC60112 -2009、UL 746A 、 ASTM D 3638-92
Standard:GB 4706.1-2008、GB 4207-2012、IEC60112 -2009、UL 746A 、 ASTM D 3638-92
外形尺寸:1120W*520D*1250H
Outside dimension:1120W*520D*1250H
电极材料:试验电极 - 铂金,电极接杆 – 紫铜或黄铜
Electrode material: test electrode - platinum, electrode rods - copper or brass
电极尺寸:2mm*5mm*40mm
electrode dimension:2mm*5mm*40mm
电极距离:4.0mm ± 0.01mm, included angle 60 ° ± 5 °
Electrode distance: 4.0mm ± 0.01mm, included angle 60 ° ± 5 °
电极压力:1.00N ± 0.001N
Electrode pressure: 1.00N ± 0.001N
试液电阻:A 液 0.1%NH4Cl,3.95±0.05Ωm, B 液 1.98±0.05Ωm
Test solution resistance: liquid A 0.1% NH4Cl, 3.95 ± 0.05Ωm, liquid B 1.98 ± 0.05Ωm
液滴体积 :20 滴 0.380g ~ 0.480g , 50 滴 0.997g ~ 1.147g ( 可微调节 )
Liquid droplet volume: 20 drops 0.380g to 0.480g, 50 drops 0.997g to 1.147g (adjustable)
液滴高度 :35mm ± 5mm ( 可调节 );
Drop height: 35mm ± 5mm (adjustable)
液滴时间 :30s±0.1s( 优于标准 )( 数显,可预置调节 ) , 50 滴时间 24.5min±2min;
Droplet Time: 30s ± 0.1s (over the standard) (digital display, can be pre-adjusted), 50 drops of time 24.5min ± 2min
液滴滴数 :1 ~ 9999( 数显,可直接设定);
Droplet number: 1 to 9999 (digital display, can be set directly)
试验风速 :0.2m /s( 新标准 );
Test wind speed: 0.2m / s (new standard)
试验电压 :100V ~ 600V(25V 分度,可调节 );
Test Voltage: 100V ~ 600V (25V indexing adjustable)
电源压降 :1.0A ± 0.1A 时 8%;
Power supply voltage drop: 8% at 1.0A ± 0.1A
起痕判断 :0.50A ±10% , 2.00s±10% ;
Tracking judgment: 0.50A ± 10%, 2.00s ± 10%
试验电源 :220V 0.6kVA 50-60Hz
Test power: 220V 0.6kVA 50-60Hz
二、耐电痕化指数测试仪产品特点
1、可编程控制器触摸屏+PLC控制
2、电压、启动排液、切换、电流、停止、排风、照明均在触摸屏上实现,试验数据可存储在触摸屏内,试验结束自动跳出保存界面,填写1、保存名称即可保存数据,所有保存的数据均可在历史数据里查询
4、电压大小、滴液时间、电流大小、滴液次数、设备门状态、总线大电流、实验结果实时显示
5、七寸全彩触摸屏
6、控制液滴采用进口电磁阀,的控制液滴的大小,无需调节!
7、机器有排液功能,方便实验前排空管路内的空气!
8、采用精密泄漏电流表来迅速判定产品漏电流大小(保证CTI指数性)!
9、可精密调节样品台的高低,精密调节2个电极的前后左右位置,方便试验进行(完全参照TESTING夹具改进,使用方便)
10、照明灯具采用标准防爆灯具,符合安全标准
11、采用正野密封排风扇保证箱体密封。且排风效果强!
12、箱体板档喷涂外箱,美观大方,操作简便
13、产品配件含精密电子称来考证电极头对试样作用力!
14、测试结束自动判定试验是否合格