BOD self check measurement OxiTop ® Control



Evaluation possibility/data transfer to PC for documentation according to GLP with the respirometric OxiTop ® Control meter for BOD self check measurement
Convenient operation via controller
Suitable for large sample volumes - up to 100 parallel samples
Time-saving and error-free with automatic statistical evaluation
Simple allocation by automatic sample ID
Complete package for 6 or 12 measuring points for large sample volumes:
This system is the successor of the OxiTop ® system. With a practical controller, the OC 100, is has an infrared interface and software-controlled functions: You can start, manage, save and track 100 measuring heads at the same time on a large display, also grouped together. The data can be transferred to the PC for evaluation via the cable AK-540/B and the communications program Achat OC.
For users who have other applications than just BOD, OxiTop ® Control S6 / S12 with the OC 110 is the right choice.
Variations
| Model | De |
Order no. | |||
|---|---|---|---|---|---|
| OxiTop ® -C IS 12 | 12 measuring points without controller | 208133 | |||
| OxiTop ® -C IS 6 | 6 measuring points without controller | 208130 | |||
| OxiTop ® Control 6 | Set with 6 measuring points | 208201 | |||
| OxiTop ® Control 12 | Set with 12 measuring points | 208204 | |||
| OxiTop ® OC 100 | Controller | 208207 | |||
Technical Data
| OC 100 | |
| Measuring range | 500 to 1350 hPa |
| Accuracy | ±1 % v. Mw. ± 1hPa |
| Data sets (depending on measuring interval) | 180 to 360 data sets per head |
| Measuring interval | 0.5 h to 99 days |
| Measuring range | 0 to 4000 mg/l BSB |
| OxiTop ® -C, OxiTop ® -C/B |
Matching and supplemental products
Stirring platforms
Thermo boxes
Thermo cabinets
Overflow measuring flask
Accessories
| Model | De |
Order no. | |||
|---|---|---|---|---|---|
| OxiTop ® -C 2 | 2 measuring heads | 208823 | |||
| AK 540/B | Interface cable | 902842 | |||
| OxiTop ® -C/B | Measuring head biogas | 208831 | |||
| OxiTop ® PM | Calibration tablets | 209333 | |||
| NTH 600 | Nitrification inhibitor | 209331 | |||
| OxiTop ® -C | Measuring head | 208830 | |||
| NHP 600 | Sodium hydroxide pads | 209140 | |||
| OxiTop ® -C 6 | 6 measuring heads | 208822 | |||
| OxiTop ® PT | Leakage test material | 209334 | |||
Downloads