HX-DJ-DV/M(G)南京斯沃消防电源监控模块可以放在箱内

发布时间:2021-04-10

|HX-DJ-DV/M(G)-内容提要(Synopsis)

******销售   189  、6369、7816****** 

HX-DJ-DV/M(G)消防电源监控模块可以放在箱内三相四线双电源电压传感器用于采集消防设备电源为两路(主、备电)三相四线电源的电压数值,经通讯上传至消防设备电源监控器,消防设备电源监控器通过分析、处理判断消防设备电源是否有断路、断相、过压、欠压以及缺相等故障并报警、记录的监控系统,消防设备电源状态监控器,通过检测消防设备电源的电流、电压值和开关状态,判断电源是否存在断路、过压、欠压、过流以及缺相、错相等状态并进行报警和记录,

HX-DJ-DV/M(G)南京斯沃消防电源监控模块可以放在箱内

 

|HX-DJ-DV/M(G)细节描述(Detailed deion)
·程序为我公司独立开发,可以根据客户的需求予以定制特殊的功能;
·继电器采用的是国内,使用寿命比常规的要好的多;继电器正常的在六万次以上,其他在七千次左右;
·所有出厂的产品都有刷三防漆,防水、防潮、防腐方面都要好;核心件都是进口件。

·The program is independently developed by our company, and special functions can be customized according to the needs of customers;

·The relay adopts domestic famous brands, and its service life is much better than that of the conventional ones; the normal relay is more than 60000 times, and other brands are about 7000 times;

·All factory products are painted with three proofing paints, which are better in waterproof, moisture-proof and anti-corrosion aspects; the core parts are imported ones.


|
HX-DJ-DV/M(G)消防电源监控模块可以放在箱内

■ HX-DJ-DV/M(G)监测功能:监测消防电源电压、电流异常状态:主、备电源的过压、欠压、过流、错相、缺相、供电中断等故障状态
■ 统计功能:统计故障信息,形成SOE记录
■ 故障/报警功能:灯光报警
■ 通讯功能:通过智能通讯总线,将信息以数字化的形式进行远程传输,具有高度抗干扰能力
■ 其它功能:自检重要元器件;存储64条报警和故障记录,掉电后可保存10年

■ HX-DJ-DV/M(G)monitoring function: monitoring the abnormal state of fire power supply voltage and current: overvoltage, undervoltage, overcurrent, wrong phase, missing phase, power supply interruption and other fault states of main and standby power supply
■Statistics function: Statistics fault information and form SOE record
■Fault / alarm function: light alarm
■Communication function: remote transmission of information in digital form through intelligent communication bus, with high anti-interference ability
■Other functions: self check important components; store 64 alarm and fault records, which can be sed for 10 years after power failure

 

|HX-DJ-DV/M(G)产品图片(Product picture)

HX-DJ-DV/M(G)南京斯沃消防电源监控模块可以放在箱内

 

|HX-DJ-DV/M(G)技术指标(Technical index)
HX-DJ-DV/M(G)供电电压 DC24V由监控器或区域分机集中供电
额定功率 <0.5W
总线通信方式 CAN总线
通信线+电源线要求 NH-RVS2*1.5mm2(通信线)+NH-BV2*2.5mm2(电源线)
输出参数 1路无源触点,报警或控制输出
地址编码 每台传感器均具有地址编码
测量范围  AC20~500V DC10~30V AC0~1000A DC0~100A
隔离器         每台传感器内自带隔离器
报警参数 过压>额定电压的110%,欠压<额定电压的85%,电流报警值现场设定
报警显示 LED指示
报警延时 0~60S连续可调,现场可设定
环境温度  -20℃~+70℃
环境湿度 相对湿度≤95%
海拔高度 <4500m
防护等级 IP30
外形尺寸 110mm*85mm*45mm(长*宽*高)
安装方式 标准35mm导轨式安装

The power supply voltage is ﹥ DC24 V, which is supplied by the monitor or regional extension
Rated power < 0.5W
Bus communication mode: can bus
Communication line + power line: nh-rvs2 * 1.5mm2 (communication line) + nh-bv2 * 2.5mm2 (power line)
Output parameter: 1-way passive contact, alarm or control output
Address code each sensor has a unique address code
Measuring range: ac20 ~ 500V, DC10 ~ 30V, ac0 ~ 1000A, dc0 ~ 100A
Isolator each sensor has its own isolator
Alarm parameters: overvoltage > 110% of rated voltage, undervoltage < 85% of rated voltage, current alarm value is set on site
Alarm display LED indication
The alarm delay can be adjusted continuously from 0 to 60s, and can be set on site
Ambient temperature - 20 ℃~ + 70 ℃
Ambient humidity: > relative humidity ≤ 95%
Altitude < 4500m
The protection level is less than IP30
Overall dimension: 110mm * 85mm * 45mm (L * w * h)
Installation method: Standard 35mm rail installation

【内部随机图片】

 


|HX-DJ-DV/M(G)安装注意事项(Installation precautions)
在值班人员经常工作的一面,设备面盘至墙的距离不应小于3m; 合理使用监控模块,应该有甄选,使用直流还是交流模块,监测单相电源还是三相电流,根据消防设备类型选着电压型监控模块、电流型监控模块,电流兼电压型监控模块,不能随意使用,造成使用混乱、功能不全或给投资方造成成本浪费,施工方应在安装监控模块时规范操作,杜绝安装模块式对电缆、断路器造成损害,留下隐患。导线应绑扎成束;    

 

|HX-DJ-DV/M(G)试验设备(Test equipment)
每一个设备出厂前都会经过一整套完整的试验流程以保证它的品质:
--Step 1--静电放电发生器
--Step 2--多功能抗干扰测试
--Step 3--可程式恒温湿试验机
--Step 4--老温老化房
--Step 5--初校验台
--Step 6--复校验台
--Step 7--电能走字台

 Every equipment will go through a complete set of test process before leing the factory to ensure its quality
--Step 1 -- electrostatic discharge generator
--Step 2 -- multi function anti interference test
--Step 3 -- programmable constant temperature and humidity testing machine
--Step 4 -- aging room
--Step 5 -- preliminary calibration platform
--Step 6 -- recheck bench
--Step 7 -- electric energy walking platform

 

 |HX-DJ-DV/M(G)相关电工知识(Relevant electrical knowledge)

  为什么不行。当你开灯的时候,火线从空气开关出,零线从漏电保护器出,这样子漏电保护器就没办法检测到零线和火线的电流,所以就会跳闸。这种漏电跳闸不属于正常的保护跳闸,而是误动作。也就是说其实并没有漏电,只是走了不同的回路,但是漏电保护器它检测不到,所以他以为是漏电了,所以跳闸。  如果你到工厂去做电工,一打开电控柜可能就傻了眼,很多器件不认识,也不知道从开始。很可能面试都通不过。如果你确实想从事电工这个行业,的方式就是先找一个师傅,自己信得过,技术也好,也愿意教你的师傅,以电工学徒的名义跟这个师傅当厂里面去学,这种方式是学电工*快的方法。  常见的减压启动方法有星三角降压启...想要把三相电接一个家用照明电来使用,应该是比较容易办到的事情,只要任意选择三相电中的一根火线(相线),与共用零线组合使用,就是一个220伏的单相供用电线路了,可以作为照明及其它的单相电器用电。  随着微处理器、计算机和数字通信技术的迅速发展,计算机控制几乎已扩展到所有行业。为了适应现代社会的需要,工业产品必须对市场需求作出快速反应,生产小批量、多层次、多功能、低成本、高质量的产品,自动化生产控制系统必须具有足够的可靠性和灵活性。 

 

|团队实力(Team strength)
我们专注于中低压电气元器件的开发和生产,具备一支10年行业经验的优良产品研发团队。
一、研发团队
公司每年将营业收入的10%投入到研发和技术创新方面,以确保优先一步的技术与产品
二、技术团队
*的维保和售后技术已解决您的后顾之忧
三、销售团队
定期组织员工进行*知识培训以及现场实勘

We focus on the development and production of medium and low voltage electrical components, and he an excellent product R & D team with 10 years of industry experience.
1、 R & D team
Every year, the company invests 10% of its revenue into R & D and technological innovation to ensure the priority of technology and products
2、 Technical team
Professional maintenance and after-sales technology has solved your worries
3、 Sales team
Regularly organize staff to carry out professional knowledge training and field survey

 

========HX-DJ-DV/M(G)南京斯沃消防电源监控模块可以放在箱内南京斯沃为您服务!=========

========HX-DJ-DV/M(G)南京斯沃消防电源监控模块可以放在箱内南京斯沃为您服务!=========

 

上一篇:台州西门子电机控制设备代理商欢迎...
下一篇:安庆市宜秀区西门子PLC模块回收