 技术参数                                    
管径                                             DN15 to DN400
 测量范围                                   0.1 m/s to 10 m/s
 测量误差                                     ≤ ±2% o.R. (1-10 m/s)

 1                                                   with manual works calibration or Teach-In
                                                     ≤ ±4% o.R. (1-10 m/s)
 1)
 进口burkert压力变送器,德国宝德压力变送器
  with standard K-factor for ftting
 线性度                                         ≤ ±(1% o.R. + 0.1% fs)
 1)
 
 重复性                                         ±0.25% o.R.
 1)
 
  材质
 传感器                                         不锈钢316L  (1.4404)
 密封                                             EPDM
 电极                                             不锈钢316L(1.4404)
 5-pin M12 female cable connector with plastic threaded locking ring                         
5-pin M12 female connector moulded-on cable (2 m shielded)                                 
4-pin M12 male cable connector with plastic threaded locking ring                            
4-pin M12 male connector moulded-on cable (2 m shielded)                                    
8-pin M12 female cable connector with plastic threaded locking ring                         
8-pin M12 female connector moulded-on cable (2 m)                                                 
2-pin M12 female coupler module for ribbon cable (AS-Interface version only)    

8045型电磁流量变送器适用于DN15至DN400的管道以及电导率大于20μS/cm的液体。该变送器具有大显示屏、键盘并提供4-20mA、继电器和脉冲输出信号。
不锈钢传感器式适用于高温(高110℃)高压(PN 16)介质。

德国BURKERT压力变送器,宝德变送器

德国宝德压力变送器工作原理及故障诊断
在测量过程中,变速器常常会出现一些故障,对正在进行了生产来说,及时判定分析和处理行是至关重要的。根据日常维护中的经验,人们结归纳了一些判定分析方法和分析流程。
(1)调查法。回顾故障发生前的打火、冒烟、异味、供电变化、雷击、潮湿、误操作、误维修。
(2)直观法。观察回路的外部损伤、导压管的泄漏,回路的过热,供电开关状态等。
(3)检测法。  联系人:唐玙昺  QQ:二七八八七六四四七   电话:〇二一 三六三一四三六九   传真:〇二一  无二三七一六九七   上海市黄浦区北京东路六六八号上海科技京城东楼20C2
断路检测:将怀疑有故障的部分与其它部分分开来,查看故障是否消失,如果消失,则确定故障所在,否则可进行下一步查找,如:智能差压变送器不能正常Hart远程通讯,可将电源从仪表本体上断开,用现场另加电源的方法为变送器通电进行通讯,以查看是否电缆是否叠加约2kHz的电磁信号而干扰通讯。
短路检测:在保证安全的情况下,将相关部分回路直接短接,如:差变送器输出值偏小,可将导压管断开,从一次取压阀外直接将差压信号直接引到差压力变送器双侧,观察变送器输出,以判断导压管路的堵、漏的连通性。
替换检测:将怀疑有故障的部分更换,判断故障部位。如:怀疑变送器电路板发生故障,可临时更换一块,以确定原因。
分部检测:将测量回路分割成几个部分,如:供电电源、信号输出、信号变送、信号检测,按分部分检查,由简至繁,由表及里,缩小范围,找出故障位置。

146982M 2712-A2-100-EE-VA-SA41-C-F-N1-0000  146983N 2712-A2-100-EE-VA-SD40-C-F-N1-0000
146985Q 2712-B2-100-EE-VA-FD21-C-F-N1-0000  146986R 2712-B2-100-EE-VA-GM83-C-F-N1-0000
146988T 2712-B2-100-EE-VA-SA41-C-F-N1-0000  146989U 2712-B2-100-EE-VA-SD40-C-F-N1-0000
146991N 2712-A2-100-EE-VA-FD22-C-F-N1-0000  146992P 2712-A2-100-EE-VA-GM84-C-F-N1-0000
146993Q 2712-A2-100-EE-VA-NM84-C-F-N1-0000  146994R 2712-A2-100-EE-VA-SA42-C-F-N1-0000
146995J 2712-A2-100-EE-VA-SD42-C-F-N1-0000  146998V 2712-B2-100-EE-VA-FD22-C-F-N1-0000
146999W 2712-B2-100-EE-VA-GM84-C-F-N1-0000  147002T 2712-B2-100-EE-VA-SD42-C-F-N1-0000
147004V 2712-A2-100-EE-VA-FA03-C-F-N2-0000  147005W 2712-A2-100-EE-VA-FD23-C-F-N2-0000
147006X 2712-A2-100-EE-VA-GM85-C-F-N2-0000  147008H 2712-A2-100-EE-VA-SA43-C-F-N2-0000
147009A 2712-A2-100-EE-VA-SD43-C-F-N2-0000  147012L 2712-B2-100-EE-VA-FD23-C-F-N2-0000 
147013M 2712-B2-100-EE-VA-GM85-C-F-N2-0000  147015P 2712-B2-100-EE-VA-SA43-C-F-N2-0000
147016Q 2712-B2-100-EE-VA-SD43-C-F-N2-0000  147019T 2712-A2-150-EE-VA-FD22-C-F-N1-0000
147020Y 2712-A2-150-EE-VA-GM84-C-F-N1-0000  147021M 2712-A2-150-EE-VA-NM84-C-F-N1-0000
147022N 2712-A2-150-EE-VA-SA42-C-F-N1-0000  147023P 2712-A2-150-EE-VA-SD42-C-F-N1-0000
147026J 2712-B2-150-EE-VA-FD22-C-F-N1-0000  147027K 2712-B2-150-EE-VA-GM84-C-F-N1-0000
147029V 2712-B2-150-EE-VA-SA42-C-F-N1-0000  147030S 2712-B2-150-EE-VA-SD42-C-F-N1-0000
147033R 2712-A2-150-EE-VA-FD23-C-F-N2-0000  147034J 2712-A2-150-EE-VA-GM85-C-F-N2-0000
147035K 2712-A2-150-EE-VA-NM85-C-F-N2-0000  147036L 2712-A2-150-EE-VA-SA43-C-F-N2-0000
147037M 2712-A2-150-EE-VA-SD43-C-F-N2-0000  147040C 2712-B2-150-EE-VA-FD23-C-F-N2-0000
147041Z 2712-B2-150-EE-VA-GM85-C-F-N2-0000  147043T 2712-B2-150-EE-VA-SA43-C-F-N2-0000
147044U 2712-B2-150-EE-VA-SD43-C-F-N2-0000  147047X 2712-A2-150-EE-VA-FD24-C-F-N3-0000
147048G 2712-A2-150-EE-VA-GM86-C-F-N3-0000  147049H 2712-A2-150-EE-VA-NM86-C-F-N3-0000
147050E 2712-A2-150-EE-VA-SA44-C-F-N3-0000  147051T 2712-A2-150-EE-VA-SD44-C-F-N3-0000
147052U 2712-A2-100-EE-VA-SODF-C-F-N2-0000  147054W 2712-B2-150-EE-VA-FD24-C-F-N3-0000
147057Z 2712-B2-150-EE-VA-SA44-C-F-N3-0000  147058A 2712-B2-150-EE-VA-SD44-C-F-N3-0000
147061V 2712-A2-200-EE-VA-FD23-C-F-N2-0000  147062W 2712-A2-200-EE-VA-GM85-C-F-N2-0000
147063X 2712-A2-200-EE-VA-NM85-C-F-N2-0000  147064Y 2712-A2-200-EE-VA-SA43-C-F-N2-0000
147065Z 2712-A2-200-EE-VA-SD43-C-F-N2-0000  147066S 2712-A2-150-EE-VA-SODE-C-F-N1-0000
147068C 2712-B2-200-EE-VA-FD23-C-F-N2-0000  147069D 2712-B2-200-EE-VA-GM85-C-F-N2-0000
147071X 2712-B2-200-EE-VA-SA43-C-F-N2-0000  147072Y 2712-B2-200-EE-VA-SD43-C-F-N2-0000
147075T 2712-A2-200-EE-VA-FD24-C-F-N3-0000  147076U 2712-A2-200-EE-VA-GM86-C-F-N3-0000
147078E 2712-A2-200-EE-VA-SA44-C-F-N3-0000  147079F 2712-A2-200-EE-VA-SD44-C-F-N3-0000
147080V 2712-A2-150-EE-VA-SODF-C-F-N2-0000  147082K 2712-B2-200-EE-VA-FD24-C-F-N3-0000
147083L 2712-B2-200-EE-VA-GM86-C-F-N3-0000  147085N 2712-B2-200-EE-VA-SA44-C-F-N3-0000
147086P 2712-B2-200-EE-VA-SD44-C-F-N3-0000  147089S 2712-A2-200-EE-VA-FD25-C-G-N4-0000
147090X 2712-A2-200-EE-VA-GM87-C-G-N2M 2712-A2-200-EE-VA-SA45-C-G-N4-0000
147093N 2712-A2-200-EE-VA-SD45-C-G-N5Q 2712-B2-200-EE-VA-FD25-C-G-N4-0000
147096R 2712-B2-200-EE-VA-GM87-C-G-N8T 2712-B2-200-EE-VA-SA45-C-G-N4-0000

德国BURKERT压力变送器,宝德变送器