·ISO 18233:2006. Acoustics — Application of new measurement methods in building and room acoustics
·ISO 3382. Acoustics — Measurement of room acoustic parameters
oPart 1:2009. Performance spaces
oPart 2:2008. Reverberation time in ordinary rooms
·IEC 60268. Sound system equipment
oPart 16:2003. Objective rating of speech intelligibility by speech transmission index
·ISO 140 series. Acoustics — Measurement of sound isulation in buildings and of building elements
·ISO 717 series. Acoustics — Rating of sound isulation in buildings and of building elements
室内声学
·室内声学特性可用室内脉冲响应测量推导出的声学参数来描述
·ISO3382国际标准定义了这些参数:
o混响时间 (EDT, RT20, RT30, RTU)
o早期/晚期能量比 (C50, C80, D, ts)
o声压级和力度 (G)
o背景噪声
o语音传输指数是描述人声传输质量很重要的一个因素
室内脉冲响应
室内的声音传输可视为一个线性系统,音源到麦克风的脉冲响应可用不同的方式测得:
·长序列 MLS (ISO3382 & ISO18233)
·正弦波扫描 SS (ISO3382 & ISO18233)
·脉冲音源直接测量 (ISO3382)
现场典型测量应用图示:
室内脉冲响应可用扬声器为音源以MLS长序列讯号或正弦波扫描法测得
CLIO 10测量脉冲响应
MLS:
- 多512K点,以48k Hz取样可得长10.8秒的脉冲响应
- 白噪声频谱
- STI 语音传输指数计算
LogChirp:
- 多512K点,以48k Hz取样可得长10.8秒的脉冲响应
- 对数正弦波扫描
- 粉红噪声频谱
- 失真分离
图示脉冲响应谱:
直接测量脉冲声源
**
气球爆破声
CLIO10实时记录脉冲
由MIC直接输入给Clio用Leq音压位准分析功能
用外部录音装置
脉冲必须存成.wav格式档案
脉冲到声学参数的推导:
用测得脉冲响应可计算声学参数
每八度或1/3八度音程频带的声压衰减曲线以脉冲的逆积分求得
可补偿背景噪声
CLIO10 硬件能确保准确知道讯号位准
衰减分析
CLIO 可分析每个频段的衰减情形
声学参数
CLIO 可显示声学参数应对不同频率的变化
STI (语音传输指数)
若用MLS测脉冲响应可计算不同频率的语音传输指数
(D.Rife, "Modulation Transfer Function Measurement with Maximum-Length Sequences", JAES Volume 40 Issue 10
pp. 779-790; October 1992)
-----------------------------------------------------
STI index
-----------------------------------------------------
Oct.Band 125 250 500 1k 2k 4k 8k
f1=0.63 0.745 0.811 0.761 0.813 0.829 0.880 0.972
f2=0.80 0.686 0.739 0.688 0.747 0.755 0.801 0.890
f3=1.00 0.644 0.686 0.633 0.699 0.699 0.741 0.827
f4=1.25 0.579 0.604 0.556 0.635 0.616 0.651 0.733
f5=1.60 0.523 0.536 0.510 0.592 0.553 0.581 0.661
f6=2.00 0.477 0.478 0.485 0.558 0.501 0.521 0.602
f7=2.50 0.415 0.404 0.458 0.525 0.431 0.438 0.527
f8=3.15 0.345 0.338 0.434 0.504 0.362 0.353 0.461
f9=4.00 0.298 0.302 0.427 0.455 0.235 0.166 0.373
f10=5.00 0.353 0.260 0.421 0.405 0.204 0.090 0.361
f11=6.30 0.442 0.144 0.368 0.415 0.317 0.363 0.462
f12=8.00 0.563 0.493 0.447 0.493 0.450 0.548 0.650
f.392 0.379 0.495 0.403 0.505 0.687
f.298 0.340 0.477 0.272 0.379 0.507
-----------------------------------------------------
MTI 0.489 0.463 0.493 0.558 0.473 0.501 0.623
STI=0.512 ALcons=10.6% rated Fair
小波分析
小波分析是可应用于室内声学评价的强大工具
测得脉冲响应可于时间-频率界面同时检视
下例为采用吸音与扩散方式控制回响与共振的效果示范
建筑声学
空气隔声
测量声音显明减少指数R'
R'的测量取决于
L1: 发射音压级
L2: 接收音压级
背景噪声
S: 隔音面
A: 接收吸音系数
室内声学与建筑声学
测量设备
参考标准:
·IEC 61672:2003. Electroacoustics — Sound level meters. (replacing former IEC 651, Sound level meters and IEC 804, Integrating-averaging sound level meters)
·IEC 61260:2001. Electroacoustics — Octave-band and fractional-octave-band filters
室内声学与建筑声学测量设备:
实验室与工程用
室内声学与建筑声学测量设备:
一类验证器材