(CLIO在房间声学与建筑声学中的应用)上篇

发布时间:2016-01-08
室内声学与建筑声学参考标准:

·ISO 18233:2006. Acoustics — Application of new measurement methods in building and room acoustics

·ISO 3382. Acoustics — Measurement of room acoustic parameters

oPart 1:2009. Performance spaces

oPart 2:2008. Reverberation time in ordinary rooms

·IEC 60268. Sound system equipment

oPart 16:2003. Objective rating of speech intelligibility by speech transmission index

·ISO 140 series. Acoustics — Measurement of sound isulation in buildings and of building elements

·ISO 717 series. Acoustics — Rating of sound isulation in buildings and of building elements

室内声学

·室内声学特性可用室内脉冲响应测量推导出的声学参数来描述

·ISO3382国际标准定义了这些参数:

o混响时间 (EDT, RT20, RT30, RTU)

o早期/晚期能量比 (C50, C80, D, ts)

o声压级和力度 (G)

o背景噪声

o语音传输指数是描述人声传输质量很重要的一个因素

室内脉冲响应

室内的声音传输可视为一个线性系统,音源到麦克风的脉冲响应可用不同的方式测得:

·长序列 MLS (ISO3382 & ISO18233)

·正弦波扫描 SS (ISO3382 & ISO18233)

·脉冲音源直接测量 (ISO3382)

现场典型测量应用图示:

室内脉冲响应可用扬声器为音源以MLS长序列讯号或正弦波扫描法测得

 

 

CLIO 10测量脉冲响应

MLS:

-  多512K点,以48k Hz取样可得长10.8秒的脉冲响应

-  白噪声频谱

-  STI 语音传输指数计算

 

LogChirp:

-  多512K点,以48k Hz取样可得长10.8秒的脉冲响应

-  对数正弦波扫描

-  粉红噪声频谱

-  失真分离

图示脉冲响应谱:

 

 

 

直接测量脉冲声源

  **

  气球爆破声

 

CLIO10实时记录脉冲

 由MIC直接输入给Clio用Leq音压位准分析功能

 用外部录音装置

 脉冲必须存成.wav格式档案

 

脉冲到声学参数的推导:

 用测得脉冲响应可计算声学参数

 每八度或1/3八度音程频带的声压衰减曲线以脉冲的逆积分求得

 可补偿背景噪声

 CLIO10 硬件能确保准确知道讯号位准

衰减分析

 CLIO 可分析每个频段的衰减情形

 

声学参数

 CLIO 可显示声学参数应对不同频率的变化

 

STI (语音传输指数)

  若用MLS测脉冲响应可计算不同频率的语音传输指数

(D.Rife, "Modulation Transfer Function Measurement with Maximum-Length Sequences", JAES Volume 40 Issue 10

pp. 779-790; October 1992)

-----------------------------------------------------

STI index

-----------------------------------------------------

Oct.Band   125     250     500     1k       2k     4k      8k

f1=0.63   0.745   0.811   0.761   0.813   0.829   0.880   0.972

f2=0.80   0.686   0.739   0.688   0.747   0.755   0.801   0.890

f3=1.00   0.644   0.686   0.633   0.699   0.699   0.741   0.827

f4=1.25   0.579   0.604   0.556   0.635   0.616   0.651   0.733

f5=1.60   0.523   0.536   0.510   0.592   0.553   0.581   0.661

f6=2.00   0.477   0.478   0.485   0.558   0.501   0.521   0.602

f7=2.50   0.415   0.404   0.458   0.525   0.431   0.438   0.527

f8=3.15   0.345   0.338   0.434   0.504   0.362   0.353   0.461

f9=4.00   0.298   0.302   0.427   0.455   0.235   0.166   0.373

f10=5.00  0.353   0.260   0.421   0.405   0.204   0.090   0.361

f11=6.30  0.442   0.144   0.368   0.415   0.317   0.363   0.462

f12=8.00  0.563   0.493   0.447   0.493   0.450   0.548   0.650

f.392   0.379   0.495   0.403   0.505   0.687

f.298   0.340   0.477   0.272   0.379   0.507

-----------------------------------------------------  

MTI       0.489   0.463   0.493   0.558   0.473   0.501   0.623

STI=0.512     ALcons=10.6%     rated Fair

 

小波分析

 小波分析是可应用于室内声学评价的强大工具

 测得脉冲响应可于时间-频率界面同时检视

 下例为采用吸音与扩散方式控制回响与共振的效果示范

建筑声学

空气隔声

测量声音显明减少指数R'

R'的测量取决于

 L1: 发射音压级

 L2: 接收音压级

 背景噪声

 S: 隔音面

 A: 接收吸音系数

 

 

室内声学与建筑声学

测量设备

 参考标准:

·IEC 61672:2003. Electroacoustics — Sound level meters. (replacing former IEC 651, Sound level meters and IEC 804, Integrating-averaging sound level meters)

·IEC 61260:2001. Electroacoustics — Octave-band and fractional-octave-band filters

室内声学与建筑声学测量设备:

实验室与工程用

室内声学与建筑声学测量设备:

一类验证器材

 