HPC600002CGSF便携式自动压力校准器

发布时间:2016-01-16

HPC600002CGSF便携式自动压力校准器


压力校准器也叫压力校准仪,是一种用于校准压力变送器、压力开关和压力表的十分精密的校准仪表。低中量程使用气体,高量程使用液体。在其壳体内装增压泵、高精度传感器和电子测量设备。

Pressure calibrator, pressure calibrator is also called, is a kind of used to calibrate the pressure transmitter, pressure switch and pressure table very precise calibration instrument. Low medium range using gas, high range using liquid. Pressure pump, high precision sensor and electronic measuring equipment in the shell body.


压力校验仪,是为校验各种压力变送器﹑压力传感器﹑压力开关﹑差压变送器﹑数字压力表﹑压力校验仪器。在测量压力的同时,也,所测压力与设定的压力百分数及测量电流同屏显示,电流及电流百分数可通过显示菜单选择。

Pressure calibration instrument, is to check all kinds of pressure transmitter, pressure sensor, pressure switch, differential pressure transmitter, digital pressure gauge, special pressure calibration equipment. At the same time of measuring pressure, also, the measured pressure and the set pressure percentage and the measured current with the screen display, the current and the current percentage can be selected through the display menu.

HPC600002CGSF便携式自动压力校准器压力范围
HPC600- 2A: 0 至 200kPa 绝压
HPC600- 2C: 真空 至 200kPa 表压
HPC600-10A: 0 至 1MPa 绝压
HPC600-10C: 真空 至 1MPa 表压
HPC600-020C 真空至2MPa表压


HPC600002CGSF便携式自动压力校准器的详细介绍:

  > 压力范围
HPC600- 2A: 0 至 200kPa 绝压
HPC600- 2C: 真空 至 200kPa 表压
HPC600-10A: 0 至 1MPa 绝压
HPC600-10C: 真空 至 1MPa 表压
HPC600-020C 真空至2MPa表压


> 高精度:±0.020% 读数(rdg) +0.015%全量程(F.S)
> 真正的现场校准仪,全范围温度补偿
> 内置电动压力泵,HPC600内置了自动压力源,由一台内置的电动压力/真空泵产生压力或者抽真空。
> 完善的4~20mA回路校准功能,HPC600具备了完整的回路校准功能:不但能够测量和输出mA信号,也能为变送器提供24V供电。
> 便捷的功能设置,HPC600的各种校准功能可以简便地通过菜单实现:包括阻尼测试、泄漏测试、误差计算、大/小值记录、压力开关测试等等。
> 温度测量,可配合Pt100铂电阻探头实现高精度的温度功能。
> 外部压力模块,可连接多达60多种量程的外部压力模块。

HPC600002CGSF便携式自动压力校准器大的特点是内置了一个电动压力泵,只需轻触按钮,仪器即可自动打到所需的压力或真空值。
  作为一台技术的自动压力校准仪,除了内置的电动压力泵以外,HPC600也配备了许多其他创新的压力校准功能。
   集压力校准仪、压力表、毫安校准仪、24V电压输出功能、电压表、测温仪和压力/真空泵于一体,功能的全面整合不但提高了工作效率,还大大节省了客户在设备方面的投入和支出。
  从初设计时就致力于实用至上的原则,因此HPC600提供了压力校准必须的压力转接口、软管、多功能便携软包等配件,力求使用户能够即买即用。我们提供的校准证书全球通用,使用户无论身处何处,都能够拿到HPC600之后马上开展工作。
  可以作为单独的功能使用(如当作高精度数字压力表),也可以独立完成复杂的校准工作,是帮助用户节约时间、节省支出和提高效率的得力助手。
  HPC600便携式自动压力校准仪可以满足高精度压力校准的要求。它具备了如下功能:用户自定义屏幕、15种不同的压力单位可选、24V供电、mA信号的测量和输出、百分比误差计算、电压测量、与计算机的串行通讯、连接外部压力模块的功能。另外,准确度是以读数精度表示的,与全量程准确度相比其准确度更高,可校准的压力范围更宽。温度补偿范围达到了-10至50℃,能够完全胜任在环境多变的现场进行的校准任务。
  JOFRA APM系列外置压力模块扩充了HPC的量程,扩展了HPC的适用范围。APM模块同时也可与其他JOFRA产品配合使用。
 
 
  温度测量
  使用Pt100标准铂电阻探头,实现高精度温度测量功能,而又简单。

  直观的屏幕显示
  由快捷功能键和方向键组成,操作十分方便
  开/关
  可在系统中设置自动关机时间,可有效节省电池电力。
  泄压阀和真空/压力切换阀
  压力微调旋钮 (容积调节)
  微调压力或真空的旋钮。
  完整的校准功能
  HPC600具有半自动压力开关测试、压力泄漏测试、百分比误差计算、HART电阻切入等种种的压力校准功能
  串行接口
  RS232接口用于HPC600与计算机或者APM压力模块进行连接。
  压力接口
  1/8” NPT或BSP母螺纹,300SS型不锈钢;转换成1/4” NPT公螺纹 和1/4” BSP母螺纹的转接头也作为标配包含在校准仪中。
  压力单位
  15 种不同的压力单位可选
  清晰的图形显示
  大面积背光显示屏显示了当前状态和模式,以及3个不同的校准测试界面,可以同时满足您不同的校准需要。
  电信号连接口
  HPC具备了电流测量、电压测量、温度测量和压力开关测试等功能,以及针对变送器的24VDC供电。


  JOFRACAL校准软件



  Compatible with 2010 software release


  JOFRACAL校准软件可实现全自动校准RTD热电阻,热电偶、温度开关、温度/压力变送器、压力表和压力开关的功能。JOFRACAL可配合DPC-500、HPC600、HPC500、HPC502和IPI系列压力校准仪、所有JOFRA温度产品以及AMC910、ASC300等多功能信号校准仪和ASM800扫描开关使用。当配合ASM800使用时,JOFRACAL可同时自动校准多24个温度/压力传感器。
  JOFRACAL软件能够完全控制校准流程,存储校准结果和提供校准报告。所有的校准数据都会被保存在计算机中,以便于监控各支传感器的漂移情况,以及优化校准周期。校准日程表功能可以让用户事先安排将来的校准计划。


  JOFRACAL运行要求:
  JOFRACAL运行的低硬件要求:
  • Intel® Pentium® lI 1.4 GHz 处理器
  • 64MB 内存 (使用128MB)
  • 400MB空间 (500MB)
  • 标准 VGA 显示器(分辨率800x600, 256色).分辨率1024x768
  • CD驱动器或者USB接口用于安装程序
  • 1至2个空余的RS232串行接口
  JOFRACAL运行的低软件要求:
  • Microsoft Windows® XP或Vista
  • 系统字体: MS Sans Serif and Arial



  JOFRA APM 压力模块
  JOFRA APM外置压力模块扩展了HPC的压力覆盖范围。有表压、绝压、差压和真空等各种量程共计60多种模块可供选择,每种模块均有英制单位或者公制单位的型号可供选择。
  APM 模块可用于现场或实验室。一旦APM 模块连接至HPC,HPC 主机能迅速识别APM 模块的信息,实现即插即用。


HPC600002CGSF便携式自动压力校准器的产品参数:


压力; 表压 /复合压力
bar ........................................................... -0.82 至 2 或 10
psi ........................................................... -12 至 30 或 150
压力; 绝压
Bar绝压 ....................................................... 0.2 至 2 或 10
Psi绝压 ....................................................... 3 至 30 或 150
压力单位 (内置)
用户可选....................................................... 15 种压力单位


压力准确度. (环境温度为18至 28°C)
所有压力量程 ..........................................±0.020% RDG + 0.015% F.S.
真空 ............................................................. ±0.025% F.S.


压力准确度 (环境温度为-10 至 50°C)
所有压力量程 ...........................................±0.030% RDG + 0.015% F.S.
真空 .............................................................. ±0.035% F.S.


显示
LCD .............................................................. 图形显示 (带背光)
显示分辨率 ................................................................... 5 位
刷新率 .................................................................... 每秒3次
RS232通讯接口
接口......................................................................... LEMO
串行................................ 0-5 VDC, 9600 波特率, 8 位, 无奇偶校验, 1停止位
协议 .................................................................. ASCII 语言
输入 / 输出精度 (环境温度为18值 28°C)
mA测量量程 .............................................................. 0至 24 mA
mA测量/输出精度 ............................................... ±0.015% RDG + 2 μA
变送器供电............................................................ 24 VDC ±10%
电压测量量程 ........................................................... 0至 30 VDC
电压测量精度.................................................... ±0.015% RDG + 2μV
RTD测量精度(欧姆) ..................................................... 84 至 140 Ω
RTD测量精度................................................. ±0.015% RDG + 0.02 Ω
RTD 测量精度(温度) ..................................... -40 至 105ºC / -40 至 220ºF
RTD 测量精度 @ 0ºC/32ºF ( 温度) ...................................±0.10ºC / 0.18ºF
HART® 电阻 ................................................................. 250 Ω
峰值保持时间.................................................................50 毫秒
压力开关测试 ............................................................. 5V (<1mA)
Temperature effect outside 18 to 28°C / 65 to 82°F ±0.001% F.S./°C.
介质兼容性
干净、清洁、无腐蚀性的气体
环境条件
工作温度 ................................................ -10 至 50°C / 14 至 122°F
储藏温度 .................................................-20 至 60°C / -4 至 140°F
防护等级....................................................................... IP56
压力接口
所有型号 ..................................................... 1/8” BSP或NPT母螺纹
Adapters to 1/4” NPT female and 1/4” BSP female are included as standard.
压力过载能力
过载警报 ............................................ 在过量程的20%之后显示“OL”.
电源供电
电池 ......................................................... 8 x 1.5 VDC碱性电池
电池类型 ....................................................AA, LR6, MN1500, AM3
电池寿命...................................................... 300校准循环(10 bar)
低电压报警功能 ................................................................. 是
仪器尺寸 (LxWxH)
校准仪 ............................................... 203x102x61 mm / 8x4x2.4 in
HPC600重量 (包括电池) ............................................ 920 g / 32.5 oz
校准仪, 发运尺寸 ................................... 560x350x180 mm / 22x13.8x7 in
校准仪重量, 发运重量 .............................................. 3,2 kg 
 
HPC600002CGSF便携式自动压力校准器配置:

• HPC600002CGSF便携式自动压力校准器
• 多功能便携软包
• NIST可溯源校准证书(包含真空/压力泵)
• 8 x 1.5V 碱性电池
• 1/4” NPT母螺纹转1/8” NPT公螺纹*
• 1/4” BSP母螺纹转1/8” NPT公螺纹*
• 快速连接头以及1米长压力连接管
• 电信号测试线: 红、黑各一根
• 用户手册


HPC600002CGSF便携式自动压力校准器配件 
可充电电池套件 - 选件B 
可以订购一组由8节AA可充电电池组成的电池组,以及一个充电器 
通讯线缆 - 选件 I 
的LEMO 转RS232通讯电缆(适用于HPC600). 
温度探头 - 选件 T 
为使HPC具备测温功能,我们专门设计了一支Pt100温度探头。该探头可 
通过LEMO线缆和HPC连接,实现即插即用。探头的精度达到了±0.15oC。探头的尺寸是直径4mm,长度200mm。
完整的校准系统 
HPC系列压力校准表可以作为数字校准表单独工作,或者与6款手泵组合成完整的压力校准系统,来满足所有的压力校准需求。


银飞电子主要销售通信设备、仪器仪表、电力设备、热工仪表、校准设备及工具配件。有多功能多产品校准器、电能功率校准器、活塞式压力计(气体、高压、液体、真空)、多功能电气安全校准器、示波器、频率计、万用表、阻抗分析仪、功率计、LCR数字电桥、音频分析仪、电容测试仪、电感测试仪、安规测试仪、直流电阻测试仪、网络分析仪、频谱仪、任意波形发生器、温度校准仪、数字测温仪、信号发生器、电源、电子负载、综合测试仪、信号源、滤波器测试仪、材料试验机、温度传感器、热像仪、变压器测试仪、噪声源、视频分析仪、过程校准仪、温度巡检仪、级测温电桥、黑体炉、静电放电干扰模拟器、雷击浪涌干扰模拟器、周波跌落模拟器、辐射抗扰度系统、脉冲群干扰模拟器、传导抗扰度测试系统、传导骚扰测试系统、辐射骚扰测试系统等仪器。


温馨小贴士:请您仔细阅读产品使用说明书,正确使用本产品。 
更多服务:(http://www.1001718.com ) 
公司:深圳市银飞电子科技有限公司
地址:广东省深圳市福田区华强北路群星广场A座33楼
热线:0755-23964199 23964499 23964699 23964599


上一篇:美国阿美特克黑体炉
下一篇:AQUAMETRO气体流量