CE-TEST61K

发布时间:2018-04-09

CE-TEST61K产品介绍
CE-TEST61K由深圳市金永仪仪器仪表有限公司提供CE-TEST61K

Harmonics up to order 40 (2 kHz at 50Hz) are measured and evaluated according to the standards EN 61000-3-2 and -12. This frequency range includes the emission of typical power supplies or thyristor circuits. Starting from 9 kHz the usual RF EMC standards apply, which have to be regarded beside the low frequent effects
 
Measuring of Harmonics in the range 2-9 kHz
 
 
Emmision
 
EN IEC DOW Valid until OJEU
 
Harmonic Limits  
 
61000-3-2 Ed. 1.0 with it's ammendments (<16A) Expired!  
EN61000-3-2:1995 IEC61000-3-2:1995 2001/01/01 2004/01/01 Yes
EN61000-3-2:1995/A1:1998 IEC61000-3-2:1995/A1:1997 2001/01/01 2004/01/01 Yes
EN61000-3-2:1995/A2:1998 IEC61000-3-2:1995/A2:1998 2001/01/01 2004/01/01 Yes
EN61000-3-2:1995/A14:2000 2004/01/01 2004/01/01 Yes
 
61000-3-2 Ed. 2.0 with it's ammendments (<16A)  
EN61000-3-2:2000 (2) Modified IEC61000-3-2:2000 (2) 2008/01/01 2009/02/01 Yes
EN61000-3-2:2000/A2:2005 IEC61000-3-2:2000/A1:2001 +
IEC61000-3-2:2000/A2:2004 2009/02/01 Yes
EN61000-3-2:2006 IEC61000-3-2:2005 2009/02/01 2012/07/01 Yes
EN61000-3-2:2006/A1:2009 IEC61000-3-2:2005/A1:2008 2012/07/01 Soon
EN61000-3-2:2006/prA1 (fragment 7) 77A/674/FDIS  
EN61000-3-2:2006/prA1 (fragment 8) 77A/674/FDIS  
EN61000-3-2:2006/A2:2009 IEC61000-7-2:2005/A2:2009 2012/07/01 Soon
 
61000-3-12 Ed. 2.0 (16-75A)  
EN61000-3-12:2005 IEC61000-3-12:2004 2008/02/01 Yes
  77A/705/CDV (2010/01/08)  
 
Harmonics Measurements  
 
61000-4-7 Ed. 1.0 (16 periods) Expired!  
EN61000-4-7:1993 IEC61000-4-7:1991 1993/12/01 2005/10/01 No (1)
 
61000-4-7 Ed. 2.0 (10/12 periods)  
EN61000-4-7:2002 IEC61000-4-7:2002 2005/10/01 2012/03/01 No (1)
EN61000-4-7:2002/A1:2009 IEC61000-4-7:2002/A1:2008 2012/03/01  
 
Flicker Limits  
 
61000-3-3 with it's ammendments (<16A)  
EN61000-3-3:1995 IEC61000-3-3:1994 2001/01/01 2004/05/01 Yes
EN61000-3-3:1995/A1:2001 IEC61000-3-3:1994/A1:2001 2004/05/01 2008/09/01 Yes
EN61000-3-3:1995/A2:2005 IEC61000-3-3:1994/A2:2005 2008/09/01 2011/09/01 Yes
EN61000-3-3:2008 IEC61000-3-3:2008 2011/09/01 Not yet
 
61000-3-11 (<75A)  
EN61000-3-11:2000 IEC61000-3-11:2000 2003/11/01 Yes
 
Flicker Measurements / Flicker Meter  
 
EN61000-4-15:1998 IEC61000-4-15:1997 2001/01/01 2006/03/01 No (1)
EN61000-4-15:1998/A1:2003 IEC61000-4-15:1997/A1:2003 2006/03/01 No (1)
Soon IEC61000-4-15:2010  
Immunity
 
EN IEC DOW Valid until OJEU
 
Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests  
 
61000-4-11 Ed. 2.0  
EN61000-4-11:2004 IEC61000-4-11:2004 2007/06/01 No
 
Harmonics and Interharmonics including Mains Signalling at AC Power Port, Low Frequency Immunity Tests  
 
61000-4-13  
EN61000-4-13:2002 IEC61000-4-13:2002 2005/05/01 2012/07/01 No
EN61000-4-13:2002/A1:2009 IEC61000-4-13:2002/A1:2009 2012/07/01  
 
Voltage Fluctuation Immunity Test  
 
61000-4-14  
EN61000-4-14:1999 IEC61000-4-14:1999 2002/04/01 2007/05/01 No
EN61000-4-14:1999/A1:2004 IEC61000-4-14:1999/A1:2001 2007/05/01 2012/07/01 No
EN61000-4-14:1999/:A2:2009 IEC61000-4-14:1999/A2:2009 2012/07/01  
 
Ripple on DC Input Power Port Immunity Test  
 
61000-4-17  
EN61000-4-17:1999 IEC61000-4-17:1999 2002/08/01 2007/05/01 No
EN61000-4-17:1999/A1:2004 IEC61000-4-17:1999/A1:2001 2007/05/01 2012/02/01 No
EN61000-4-17:1999/A2:2009 IEC61000-4-17:1999/A2:2008 2012/02/01  
 
Unbalance, Immunity Test  
 
61000-4-27  
EN61000-4-27:2000 IEC61000-4-27:2000 2003/09/01 2012/03/01 No
EN61000-4-27:2000/A1:2009 IEC61000-4-27:2000/A1:2009 2012/03/01  
 
Variation of Power Frequency, Immunity Test  
 
61000-4-28  
EN61000-4-28:2000 IEC61000-4-28:1999 2003/01/01 2007/05/01 No
EN61000-4-28:2000/A1:2004 IEC61000-4-28:1999/A1:2001 2007/05/01 2012/03/01 No
EN61000-4-28:2000/A2:2009 IEC61000-4-28:1999/A2:2009 2012/03/01  
 
Voltage Dips, Short Interruptions and Voltage Variations on DC Input Power Port Immunity Tests  
 
61000-4-29  

EN61000-4-29:2000 IEC61000-4-29:2000 2003/11/01 No