6SL3243-0BB30-1PA3参数

发布时间:2018-07-03

6SL3243-0BB30-1PA3参数

6SL3243-0BB30-1PA3参数


【产品名称】:6SL3243-0BB30-1PA3参数

【产品规格】:全新原装

【产品质量】:质保保证

【产品价格】:价格优势

【产品货期】:现货销售



6SL3210-1KE14-3UF1

SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE14-3UC1

SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: CANOPEN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE15-8UB1

SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE15-8UF1

SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE17-5UB1

SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE17-5UP1

SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE17-5UF1

SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE17-5UC1

SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: CANOPEN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE18-8UB1

SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE18-8UP1

SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE18-8UF1

SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

6SL3210-1KE18-8UC1

SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: CANOPEN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V

西门子G110变频器6SL3210-1KE18-8UC1

USS通信协议功能

USS协议功能遵循主-从通信机制。主站根据USS站地址发请求报文访问变频器从站,从站返回应答报文。USS总线上总线多可以连接31个变频器,总线大波特率57.6kbit/s(对于S7-200,只能达到19.2kbit/s)。

如何建立USS通信?


硬件*:
– 三芯屏蔽电缆,用于连接变频器和主站。

– USS通信必须连接在主站的接口0

– 电缆依次连接变频器直到总线后一个

– 变频器连接端子8 (P+), 9 (N-) 和 10 (M/0V)

– 为了保证通信稳定,在总线上*个和总线后一个节点需要安装终端电阻。主站上,在端子P+N-上安装终端电阻。

–在SINAMICS G110变频器上,通过前端的DIP开关设置终端电阻连接。.

*关于 SIMATIC S7-200:

– 在S7-200侧,使用带PROFIBUS连接头的PROFIBUS电缆。

– 需要注意, 信号地和M (0V)端子已经在内部提供连接

– M (0V)端子应和S7-200的电源M (0V)端子连接。不允许把总线电缆的屏蔽用作M(0V)

– S7-200侧的终端电阻通过PROFIBUS连接头上的拨码开关进行设置。

– 更多详细信息请参考S7-200系统手册第11章。

如何调试和设置参数?

以和S7-200通信为例

G110 参数*:
总线电缆连接完毕后,需要在变频器中设置USS参数。

请设置如下参数:总线地址(P2011 = 0-31),波特率(P2010 = 7),报文长度(P2012 = 2 / P2013 = 127)和报文监控时间(P2014 = 根据现场系统要求设置)。以上操作可以通过选件操作面板或者免费的软件调试工具STARTER完成。STARTER软件能够在PC机上运行,支持的系统为Windows NT/2000/XP Professional/Vista。如果通过PC连接组件连接,取下操作面板,在变频器相同位置插上和面板相同尺寸的PC适配器即可。


*设置S7-200
西门子G110变频器6SL3210-1KE18-8UC1
S7-200 programming environment:

S7-200编程环境是使用Step7 Micro/WIN软件。

同样,请参考S7-200系统手册第11章。

该软件需要补充安装一个协议库,使其能通过USS协议控制变频器。在软件中新建一个项目,在指令-> 库-> USS Protocol中调用USS通信的初始化和控制功能块。

– 初始化功能块"USS_INIT"设置S7-200interface 0使用USS协议通信。

– 用控制模块"USS_CTRL"发送控制字和速度设定值给变频器。控制字的每一位——例如ON/OFF,反转,故障应答——都是直接控制。其中,速度设定值用变频器的参考频率(参数P2000)进行换算。

在应答报文里,变频器同时返回状态字和变频器实际运行频率。这样使得已经发生的报警和故障可以被识别,变频器的运行状态可以被诊断。对这两个功能块编程,就可以独立控制总线上的变频器,允许他们运行于不同的频率设定值。

读写变频器参数:

编程软件还提供了6个附加功能块进行读写操作——3个读功能块和3个写功能块。



注意:

SINAMICS G110的参数表里有三种不同的参数显示方式:WORD/U16, DOUBLE/U32 and REAL/float。用户应该根据不同的参数类型选择相应的功能块。当执行一个写操作时,需要关注变频器的运行状态。例如,有些参数诸如电机额定数据只能在调试模式下修改,而另外一些参数,诸如斜坡上升时间(加速时间)甚至可以在变频器运行中修改。


上一篇:SITRON光电开关