美国NORTHSTAR高压探头

发布时间:2016-09-30

 上海祺煊实业有限公司经销美国皮尔逊(Pearson Electronics),美国North star,英国PEM柔性探头,Rocoil柔性探头流测试环系产品,交货及时,价格实惠,以诚信、稳定、好的服务于客户,做长期的企业路线。

美国NORTHSTAR高压探头

美国NORTHSTAR高压探头

Model Number

PVM-1 PVM-2 PVM-3 PVM-4 PVM-5 PVM-6 PVM-7  PVM-11 (PVM-10) PVM-12
Max DC/Pulsed V (kV) 40/60 40/60 40/60 40/60 60/100 60/100  60/100 10/12 25/32
Max Frequency (Mhz.) 80 80 40 120 80 80 110  50 80
Cable Impedance (ohms) 50 50* 50 50 50 50* 50  50 50
DC - 2 Hz.accuracy <0.1% <0.1% <0.1% <0.1% <0.15% <0.15% <0.15%  <0.1% <0.1%
2 Hz. - 200 Hz. accuracy <1 % <1. % <2. % <1.5 % <1 % <1 % <1.5%  <1.5 % <1.5 %
200 Hz. - 5 Mhz. accuracy <1.5% <1.5% <3% <2% <1.5% <1.5% <2%  <2.% <2.%
> 5 Mhz. Accuracy <3% <3%* <4% <5% <3% <4%* <4%  <4% <4%
Input R/C (Megohm/pf) 00/12 400/12  400/9 100(50)/15 300/7
Cable Length (ft./m) 0 .5
Standard Divider Ratio 1000:1 1000:1 10,000:1 1000:1 1000:1 1000:1 1000:1  1000:1 (100:1) 1000:1
Length (inches/cm.) 19/47 19/47 19/47 19/47 19/47 19/47 19/47  7/18 9/23


Add -2 to any PVM-1 - PVM-6 or PVM-12 part number for 2000:1 ratio  * 93 ohm cable is recommended for applications with nanosecond pulses and long (30 ft/9 meter or longer) cable.

VD Series High Voltage Probes 60 to 300 kV DC

Specialty Probes

VD series high voltage probes are floor standing high voltage probes which are designed for rugged day in - day out use. They are used in a wide range of applications ranging from television tube manufacturing to radar to advanced particle accelerator applications. Resistors with an extremely low voltage coefficient of resistance are used, and all capacitors are temperature, frequency, and voltage stabilized for the best possible performance. The probes all have field defining toroids as a standard item in order to minimize the proximity effect (stray capacitance) and maximize the reproducibility of the measurement. The high and low frequency calibrations are carefully matched before shipment. Very high frequency cable effects are also carefully compensated so accurate measurements can be made even when the cable length exceeds the pulse duration. No adjustments are necessary once the probes have been factory calibrated.

Model Number VD-60 VD-100 VD-150 VD-200 VD-300 VD-400
Max DC/Pulsed V (kV) 60/105 100/160 150/230 200/300 300/420 400/550
Max Frequency (Mhz.) 20 20 20 16 12 8
Cable Length (ft.) 30 30 30 30 30 30
DC accuracy <0.1% <0.1% <0.1% <0.1% <0.1% <0.1%
10 Hz. - 1 Mhz. Accuracy 1 % 1 % 1 % 2 % 2.5 % 3 %
>1 Mhz Accuracy 3 % 3 % 3 % 3 % 4 % 4 %
Resistance (Megohms) 800 1600 2000 2800 4500 7000
Height (inches/cm.) 20/50 24/60 30/75 40/99 54/135 72/180
Diameter (in/cm.) 11/28 11/28 12/29 1
Capacitance (approx. pf) 27 25 27 24 20 16
Base Diameter(in/cm.) 10/25 10/25 12/30 20/50 30/76* 30/76
Standard Divider Ratio 10,000:1 10,000:1 10,000:1 10,000:1 10,000:1 10,000:1

Voltage Probe Outline Drawings

Pulsed Power Formulary (794 KB)

Bare Probe Manual (345 KB)

PVM 1-4 Outline (32 KB)

PVM 5-6 Outline (31 KB)

PVM-10/11 Outline (22 KB)

VD-100 Outline (11 KB)

VD-150 Outline (5 KB)

VD-200 Outline (6 KB)

VD-300 Outline (4 KB)

VD-60 Outline (10 KB)



上一篇:荆门TTZ200公斤双面度盘台称...