Y(B)902G型汗渍色牢度烘箱

发布时间:2016-11-03

Y(B)902型汗渍色牢度烘箱现货,Y(B)902型汗渍色牢度烘箱生产厂家

Y(B)902型汗渍色牢度烘箱报价,Y(B)902型汗渍色牢度烘箱咨询热线

.温州际高检测仪器有限公司生产销售为一体的高科技企业,目前,公司已经取得“全自动透气性测试仪”,“电子土工布强力综合试验机”,“马丁代尔耐磨仪”,“电子织物强力机”,“排水板通水仪”等50多项技术(其中发明2项),3项计算机软件着作权以及十多项技术创新知识产权成果;



一、概述:

Y(B)902型汗渍色牢度烘箱是根据国外机型改进设计制造。其性能符合:GB3922-1997 《纺织品耐汗渍色牢度试验方法》IWS.TMNO.6《耐水渍色牢度试验方法》等标准对测试仪器的要求。
Y (B) 902 fastness to perspiration oven is according to the foreign advanced model design and manufacture. Its performance is in line with GB3922-1997: "textile color fastness to perspiration" IWS.TMNO.6 "test method for colour fastness to water spotting test methods" and other standards requirements of measurement instrument.
二、技术参数:
1功能模式表:
2工作室尺寸:380×330×300mm
3耗 功:300W
4电 源:AC220V50HZ
5外 形 尺寸:430(L)×380(W)×530(H)mm
6重 量:12Kg
三、使用方法:
1将仪器放置在坚固、平稳的工作台上,后部距墙≥10cm,其周围无强腐蚀性介质。
2检查仪器的电气性能,并注意无漏电、断电现象。
3接通电源,按下电源开关。
4根据需要选择测试温度,【温度】按钮在位时,仪器为普通烘干模式(37℃);在 位时,作快速烘干(70℃)。
5打开仓门,按要求将准备好的试样放入仪器,关好仓门。
6按下【启动】键,仪器开始加热(加热指示灯亮),至所定温度时(加热指示灯灭),仪器开始计时。
7【时间】键处于时,可在参数屏观察时间过程,【时间】键处于时,参数显示屏显示温度值。
8到所需烘干时间后,仪器自动停止。并响起警音,提醒操作者取出试样。
9测试结束后,关闭电源开关,切断电源。用干布擦试仓门,关好仓门。
Three, the use of methods:
1 instruments on the strong, steady work table, the rear wall distance of more than 10cm, no strong corrosive medium around it.
2 check the electrical performance of the instrument, and pay attention to the phenomenon of no leakage, power failure.
3 switch on the power supply, press the power switch.
4 according to the need to select the test temperature, [temperature] button in the office, the instrument for the general drying mode (37 degrees C), while in office, for rapid drying (70 degrees C).
5 open the door, according to the requirements of the sample will be ready to put into the instrument, close the door.
6 press [start] key, the instrument began to heat (heating indicator light), to the set temperature (the lights off), the instrument began to time.
7 [time] key is in time, can be in the parameter screen observation time process, [time] key is in, the parameter display temperature value.
8 to the required drying time, the instrument automatically stopped. And ring the alarm, remind the operator to take out the sample.
9 after the test is finished, turn off the power switch, cut off the power supply. Use dry cloth to wipe the door, shut the door.Y(B)902汗渍色牢度烘箱
四、注意事项:
1快速烘干时,易燃、易爆品切勿置入烘箱,以免发生意外。
2使用前,仪器须可靠接地,以保证安全。

3强腐蚀性介质请勿直接接触仪器,否则应在断电情况下及时清洁。


际高仪器——联系电话:    

QQ:252809083


上一篇:Allen-Bradley 17...
下一篇:加拿大XT4四合一检测仪