上海恒远提供:人肿瘤坏死因子αTNF-α英文说明书

发布时间:2012-05-08

Human         TNF-α  

FOR RESEARCH USE ONLY

Assay range:20 ng/L -400 ng/L                                  96 determinations

Purpose

This kit allows  for  the determination of TNF-α concentrations  in Human serum cell

culture supernates and other biological fluids

Principle of the assay

The kit assay Human TNF-α level in the sample use Purified Human TNF-α antibody to

coat microtiter  plate  wells make  solid-phase  antibody  then  add  TNF-α  to  wells  Combined

TNF-α  antibody  which  With  HRP  labeled  become  antibody  -  antigen  -  enzyme-antibody

complex after washing Completely Add TMB substrate solution TMB substrate becomes blue

color  At  HRP  enzyme-catalyzed  reaction  is  terminated  by  the  addition  of  a  sulphuric  acid

solution and the color change is measured spectrophotometrically at a wavelength of 450 nm.

The concentration of Human TNF-α in the samples is then determined by comparing the O.D.

of the samples to the standard curve.

Materials provided with the kit

1  wash    solution  20ml×1bottle  7  Stop Solution  6ml×1 bottle

2  HRP-Conjugate reagent  6ml×1 bottle  8  Standard (800ng/L)   0.5ml×1 bottle

3  Microelisa stripplate  12well×8strips  9  Standard diluent  1.5ml×1bottle

4  Sample diluent  6ml×1 bottle  10  Instruction  1

5  Chromogen Solution A  6ml×1 bottle  11

Closure plate

membrane

2

6  Chromogen Solution B  6ml×1 bottle  12  Sealed bags  1

Specimen requirements

1.  extract  as  soon  as  possible  after  Specimen  collectionand  according  to  the  relevant literature  and  should  be  experiment  as  soon  as  possible  after  the  extraction.  If  it  can’t

specimen can be kept in -20 ℃ to preserve Avoid repeated freeze-thaw cycles.

2.  Can’t detect the sample which contain NaN3 because NaN3 inhibits HRP active.

Assay procedure

1.  Dilute and add sample:Dilute Original density Standard as follow table:

400 ng/L

5 Standard  150µl Original density Standard+150µl Standard diluent

200 ng/L

4 Standard  150µl 5 Standard+150µl Standard diluent

100 ng/L

3 Standard  150µl 4 Standard+150µl Standard diluent

50 ng/L

2 Standard  150µl 3 Standard +150µl Standard diluent

25 ng/L

1 Standard  150µl 2 Standard +150µl Standard diluent

2.add  sample:  Set  blank  wells  separately  (blank  comparison  wells  don’t  add  sample  and

HRP-Conjugate reagent other each step operation is same). testing sample well. add Sample

dilution  40µl  to  testing  sample  well  then  add  testing  sample  10µl  (sample  final  dilution  is

5-fold) add sample to wells don’t touch the well wall as far as possible and Gently mix.

3.Incubate: After closing plate with Closure plate membrane incubate for 30 min at 37℃.

4.Configurate  liquid: 30-fold(or 20-fold) wash solution diluted 30-fold  (or 20-fold) with distilled

water and reserve.

5.Washing: Uncover Closure plate membrane discard Liquid dry by swing add washing buffer

to every well still for 30s then drain repeat 5 times dry by pat.

6. Add enzyme: Add HRP-Conjugate reagent 50µl to each well except blank well.  

7. Incubate: Operation with 3.

8. Washing: Operation with 5.

9.Color: Add Chromogen Solution A 50ul and Chromogen Solution B  to each well evade  the

light preservation for 15 min at 37℃

10.Stop  the  reaction:Add  Stop  Solution50µl  to  each well  Stop  the  reaction(the  blue  color

change to yellow color).

11. Assay:take blank well as zero Read absorbance at 450nm after Adding Stop Solution and

within 15min. Steps deion

Standard Sample diluent

 

 

Add Standard Sample diluent incubate for 30 min at 37℃.

 

 

Wash 5 timeAdd HRP-Conjugate reagent incubate for 30 min at 37℃.

 

 

Wash 5 timesAdd Chromogen Solution A and B incubate for 30 min at 37℃.

 

 

Add Stopp Solution

 

 

Read absorbance at 450nm within 15 min

 

 

calculate

Calculate

Take  the  standard  density  as  the  horizontal  the OD  value  for  the  vertical  draw  the

standard  curve on graph er Find out  the  corresponding density according  to  the  sample

OD value by the Sample curve multiplied by the dilution multiple or calculate the straight line

regression equation of the standard curve with the standard density and the OD value with the sample OD value in the equation calculate the sample density multiplied by the dilution factor

the result is the sample actual density.

Important notes

1.  The kit  takes out  from  the  refrigeration environment should be balanced 15-30 minutes  in

the room temperature ELISA plates coated if has not use up after opened the plate should

be stored in Sealed bag.

2.  washing  buffer  will  Crystallization  separation  it  can  be  heated  the  water  helps  dissolve

when dilute . Washing does not affect the result.

3.  add  Sample  with  sampler  Each  step  And  proofread  its  accuracy  frequently  avoids  the

experimental error. add sample within 5 min if the number of sample is much recommend

to use Volley .

4.  if the testing material content is excessively higher (The sample OD is bigger than the first

standard well )please dilute Sample (n-fold) Please diluente and multiplied by the dilution

factor.(×n×5).

5.  Closure plate membrane only limits the disposable use to avoid cross-contamination.

6.  The substrate evade the light preservation.

7.  Please  according  to  use  instruction  strictly  The  test  result  determination must  take  the

microtiter plate reader as a standard.

8.  All samples washing buffer and each kind of  reject should according  to  infective material

process.

9.  Do not mix reagents with those from other lots.

 

Storage and validity

1.Storage:    2-8℃.

2.validity:  six months              