加热器做工粗糙,换热效率低,会加大蒸汽的消耗量。目前流化床类干燥设备配套的干燥器不少都采用钢管缠绕翅片进行换热,钢管虽可节约材料成本,但不如采用铜管换热效果好;对排风进行再利用。从沸腾床中抽出的尾风,高于自然空气一定的温度,可利用一部分尾风进入加热器,减少蒸汽的损耗。另外,各类型的干燥设备都有自己的优点,各类型的干燥设备的组合也是节能的途径。如为节约用电量,在干燥初期采用流态化干燥,在干燥后期,采用微波干燥,即缩短干燥时间,又节约蒸汽用量。
充注冷媒的注意事项搭载有虹吸管的冷媒罐:为了保证冷媒的有效充注,虹吸管是没有接触到冷媒罐的底部的;也就是说,当罐内冷媒低于虹吸管口时,是不能保证制冷剂的液体充注。充注冷媒的管路连接1)把冷媒罐放在电子称上,如图接好管路,记录电子秤的读数,并确定要充注的冷媒重量。稍稍打开冷媒罐的开关,立刻关闭;轻按顶针阀,让气体从顶针处喷出,立刻放开(按顶针阀的时间不能按得太长,轻按一下就放开)4)重复2),操作2~3次;打开压力表的低压阀门,然后再打开冷媒罐的开关,进行充注;根据需要增加的冷媒重量,观察电子秤的读数;当充注足够的冷媒时关闭冷媒罐的开关或压力表的低压阀门开关;*不要一次充注大量的冷媒。
更多油泵型号可致电咨询!!!!!!
PV180R1K1L2NUCD+PV180R1L
PV180R1K1L2NUCC+PV180R1L
PV180R1K1L2NTCB+PV180R1L
PV180R1K1L2NSLZ+PV180+PV
PV180R1K1L2NSCZ+PV180R1L
PV180R1K1L2NFPV+PV180R1L
PV180R1K1L2NFPR+PV180R1L
PV180R1K1L2EFPV+PV180R1L
PV180R1K1K3NUPG+PV046R1L
PV180R1K1K3NMCZ+PV046R1L
PV180R1K1C1NUPZ+PVAC1PUM
PV180R1K1C1NUPR+PVAC1PMM
PV180R1K1C1NFPZ+PVAC1PPM
PV180R1K1BBNUPR+PVAC1P+P
PV180R1K1B4NYCC+PGP620A0
PV180R1K1B4NYCC+PGP517A0
PV180R1K1B4NWCZ+PVAC1ECM
PV180R1K1B4NUPZ+PVAC1P+P
PV180R1K1B4NTLD+PGP517A0
PV180R1K1B4NSLA+PGP517A0
PV180R1K1B4NFPZ+PVAC1P+P
PV180R1K1AYNWCC+PGP511A0
PV180R1K1AYNMMC+PGP511A0
PV180R1K1A4WUPZ+PVAC1E+P
PV180R1K1A4WTLB+PGP511B0
PV180R1K1A4NYCD+PGP511A0
PV180R1K1A4NWCC+PGP511A0
PV180R1K1A4NWCB+PGP511A0
PV180R1K1A4NULB+PGP511A0
PV180R1K1A4NTCB+PGP511A0
PV180R1K1A4NMLZ+PGP511+D
PV180R1K1A4NMLC+PGP511A0
PV180R1K1A4NFPD+PGP511A0
PV180R1K1A1NUPR+PVAC1EUM
PV180R1F3T1VMLA+PVAC1ECS
PV180R1E1L2NULC+PV180R1L
PV180L9L1L3NYCCK0172+PV1
PV180L9E1DGNTCZK0324+PVA
PV180L1L1T1NYLZX5841+PAD
PV180L1L1T1NYLZ4242X5864
PV180L1L1L2NUPM+PV180L1L
PV180L1L1L2NFT1+PV140L1L
PV180L1L1A4N2LB+PGP511A0
PV180L1K4T1NFPZ+PVAC1PSM
PV180L1K1T1NMT1+ZUDB1PT2
PV180L1K1T1NFTZ+ZUDB1PT2
PV180L1G1B4NUPK+PGP517A0
PV270L1D3T1N001
PV270L1L1T1NFF1
PV270R1K1B1NFPR
PV270R1K1T1NYCB
PV270R1K1D1NFWS
PV270R9K1T1NTLC
PV270R1K1T1NFWS
PV270R1K1T1NFHS
PV270R1K1T1NFPE
PV270R1K1T1NFPG
PV270R1K1T1NFPV
PV270R1K1T1NFPZ
PV270R1K1T1NFR1
PV270R1K1T1NFRC
PV270R1K1T1NFRD
PV270R1K1T1NFRP
PV270R1K1T1NMMC
PV270R9L1L3N2CCK
PV270R1K8T1NMMC
PV270R1L1BBNMRC
PV270L1K1T1NFHS
PV270L1K1T1NFRC
PV270L1K1T1V2LC
PV270L1L1T1NFRC
PV270R1L1B1NUPR
PV270R1K1A1NTLB
PV270R1K1B1NFFC
PV270R1K1B1NFRC
PV270R1K1B1NYLC
PV270R1K1T1NFFC
PV270R1K1T1NFFP
PV270R1K1T1NFF1
PV270R1K1T1NFT1
PV270R1K1T1NTCC
PV270R1K1T1NTLA
PV270R1K1T1NTLC
PV270R1K1T1NUCC
PV270R1K1T1NULA
PV270R1K1T1NULC
PV270R1K1T1NUPE
PV270R1K1T1NUPG
PV270R1K1T1NWLA
PV270R1K1T1NWLB
PV270R1K1T1NWLC
PV270R1K1T1NWLD
PV270R1K1T1NYCC
PV270R1K1T1NYLA
PV270R1K1T1NYLB
PV270R1K1T1NYLC
PV270R1K1T1NZCC
PV270R1K1T1NZCD
PV270R1K1T1NZLC
PV270R1K1T1N001
PV270R1K1T1N2CC
PV270R1K1T1N2CD
PV270R1K1T1N2LB
PV270R1K1T1N2LC
PV270R1K1T1N2LD
PV270R1K1T1N3LC
PV270R1K1T1VYLC
PV270R1K1T1V2LC
PV270R1K1T1WFDS
PV270R1K1T1WWLB
PV270R1K1T1WYLD
PV270R1L1T1NFFC
PV270R1L1LKNUPR
PV270R1L1T1NFF1
PV270R1L1T1NUPG
PV270R1L1T1NWCC
PV270R1L1T1N2LB
PV270R1L1T1WFFC
PV270R1L1LLNUPR
PV270R1L1MMNMFC
PV270R1L1MMNMRZ
PV270R1L1MMNUPM
PV270R1L1M1NUPM
PV270R1L1T1NFPV
PV270R1L1T1NMFC
PV270R1L1T1NMRC
PV270R1L1T1NMRZ
PV270R1L1T1NMR1
PV270R1L1T1NULC
油泵:PV032R1K1T1N001可查看内蒙古

判断板内外故障。电路板外围线路基本正常,可大致判断电路板存在故障。可通过电压检测和功能调试进行故障检查。象能够遥控接收有蜂鸣,内风机能正常运转,制热操作四通阀有工作声等可基本判断控制板正常。通电遥控不接收,蜂鸣异常,不操作自身工作,工作程序紊乱等可判断电路板自身有故障,或+12V及+5V电源异常,公共电源回路有断路等。不知代码含义本着先简后繁,先易后难,先外后里的常规检查手段,进行各关键点的压力,电压,电流,阻值的测量,以达到快速排除故障的目的。
为防止热电偶测量中由于电偶断丝而使控温失效造成事故,变送器中还设有断电保护电路。当热电偶断丝或接解不良时,变送器会输出大值(28mA)以使仪表切断电源。一体化温度变送有结构简单、节省引线、输出信号大、抗干扰能力强、线性好、显示仪表简单、固体模块抗震防潮、有反接保护和限流保护、工作可靠等优点。一体化温度变送器的输出为统一的4~2mA信号;可与微机系统或其它常规仪表匹配使用。也可用户要求做成防爆型或防火型测量仪表。
更多油泵型号可致电咨询!!!!!!