DHMPS3-2I消防设备电源监控模块怎么接线图能实时反应被监控设备电源的工作状态并集中显示,从而有效避免火灾发生时,消防设备由于电源故障而无法正常工作的危机情况,大限度地保障消防联动系统的可靠性,系统的系列产品能准确、实时监控消防设备供电电源的故障和异常状态,及时报警提醒有关人员消除这些隐患,保证了消防设备各级负荷供电的可靠性,
|DHMPS3-2I细节描述(Detailed de
·程序为我公司独立开发,可以根据客户的需求予以定制特殊的功能;
·继电器采用的是国内,使用寿命比常规的要好的多;继电器正常的在六万次以上,其他在七千次左右;
·所有出厂的产品都有刷三防漆,防水、防潮、防腐方面都要好;核心件都是进口件。
·The program is independently developed by our company, and special functions can be customized according to the needs of customers;
·The relay adopts domestic famous brands, and its service life is much better than that of the conventional ones; the normal relay is more than 60000 times, and other brands are about 7000 times;
·All factory products are painted with three proofing paints, which are better in waterproof, moisture-proof and anti-corrosion aspects; the core parts are imported ones.
|DHMPS3-2I消防设备电源监控模块怎么接线图
■ DHMPS3-2I监测功能:监测消防电源电压、电流异常状态:主、备电源的过压、欠压、过流、错相、缺相、供电中断等故障状态
■ 统计功能:统计故障信息,形成SOE记录
■ 故障/报警功能:灯光报警
■ 通讯功能:通过智能通讯总线,将信息以数字化的形式进行远程传输,具有高度抗干扰能力
■ 其它功能:自检重要元器件;存储64条报警和故障记录,掉电后可保存10年
■ DHMPS3-2Imonitoring function: monitoring the abnormal state of fire power supply voltage and current: overvoltage, undervoltage, overcurrent, wrong phase, missing phase, power supply interruption and other fault states of main and standby power supply
■Statistics function: Statistics fault information and form SOE record
■Fault / alarm function: light alarm
■Communication function: remote transmission of information in digital form through intelligent communication bus, with high anti-interference ability
■Other functions: self check important components; store 64 alarm and fault records, which can be sed for 10 years after power failure
|DHMPS3-2I产品图片(Product picture)
|DHMPS3-2I技术指标(Technical index)
DHMPS3-2I供电电压 DC24V由监控器或区域分机集中供电
额定功率 <0.5W
总线通信方式 CAN总线
通信线+电源线要求 NH-RVS2*1.5mm2(通信线)+NH-BV2*2.5mm2(电源线)
输出参数 1路无源触点,报警或控制输出
地址编码 每台传感器均具有地址编码
测量范围 AC20~500V DC10~30V AC0~1000A DC0~100A
隔离器 每台传感器内自带隔离器
报警参数 过压>额定电压的110%,欠压<额定电压的85%,电流报警值现场设定
报警显示 LED指示
报警延时 0~60S连续可调,现场可设定
环境温度 -20℃~+70℃
环境湿度 相对湿度≤95%
海拔高度 <4500m
防护等级 IP30
外形尺寸 110mm*85mm*45mm(长*宽*高)
安装方式 标准35mm导轨式安装
The power supply voltage is ﹥ DC24 V, which is supplied by the monitor or regional extension
Rated power < 0.5W
Bus communication mode: can bus
Communication line + power line: nh-rvs2 * 1.5mm2 (communication line) + nh-bv2 * 2.5mm2 (power line)
Output parameter: 1-way passive contact, alarm or control output
Address code each sensor has a unique address code
Measuring range: ac20 ~ 500V, DC10 ~ 30V, ac0 ~ 1000A, dc0 ~ 100A
Isolator each sensor has its own isolator
Alarm parameters: overvoltage > 110% of rated voltage, undervoltage < 85% of rated voltage, current alarm value is set on site
Alarm display LED indication
The alarm delay can be adjusted continuously from 0 to 60s, and can be set on site
Ambient temperature - 20 ℃~ + 70 ℃
Ambient humidity: > relative humidity ≤ 95%
Altitude < 4500m
The protection level is less than IP30
Overall dimension: 110mm * 85mm * 45mm (L * w * h)
Installation method: Standard 35mm rail installation
【内部随机图片】
|DHMPS3-2I安装注意事项(Installation precautions)
电缆芯线和所配导线的端部,均应标明编号,并与图纸一致,字迹清晰不易褪色; 在值班人员经常工作的一面,设备面盘至墙的距离不应小于3m; 将监控器与外部的连线断开,并将任一回路的传感器与之连接,其他回路可分别连接等效负载,接通电源,使监控器处于正常监视状态。
|DHMPS3-2I试验设备(Test equipment)
每一个设备出厂前都会经过一整套完整的试验流程以保证它的品质:
--Step 1--静电放电发生器
--Step 2--多功能抗干扰测试
--Step 3--可程式恒温湿试验机
--Step 4--老温老化房
--Step 5--初校验台
--Step 6--复校验台
--Step 7--电能走字台
Every equipment will go through a complete set of test process before leing the factory to ensure its quality
--Step 1 -- electrostatic discharge generator
--Step 2 -- multi function anti interference test
--Step 3 -- programmable constant temperature and humidity testing machine
--Step 4 -- aging room
--Step 5 -- preliminary calibration platform
--Step 6 -- recheck bench
--Step 7 -- electric energy walking platform
|DHMPS3-2I相关电工知识(Relevant electrical knowledge)
你一个月370度电不知道包...不拔插头耗电应该不是太多,但有时候不拔插头比较危险。我们家用电器一般都不会拔下插头,比如电视机,很多人都看完以后直接用遥控器关闭电源就没事了,耗电量虽然不是太大,但是存在着安全隐患。 是耗电的,虽然微乎其微,但足够危险。首先,用普通人也能理解的办法说说耗电充电器,就是将我们家里的220V交流电,转换成5V左右的直流电给充电。值得注意的是,即使不插充电,220V转5V的这个部分的电路也是工作的,至少要维持涓涓细流状态。 我觉得,首先要准备一个220伏电压的灯泡和一个漏电保护器。然后选择两条线连接到灯泡,可以正常发量的,有其中一条就是零线,我们把零线标注好。如果短时间内灯泡烧坏,那说明两条都是火线,我们也可以进行标注。如果接上之后漏电保护器跳闸,那说明其中一条是地线,然后我们又换其他的线,再继续测试,直到把所有的零线火线地线都标注完整。
|团队实力(Team strength)
我们专注于中低压电气元器件的开发和生产,具备一支10年行业经验的优良产品研发团队。
一、研发团队
公司每年将营业收入的10%投入到研发和技术创新方面,以确保优先一步的技术与产品
二、技术团队
*的维保和售后技术已解决您的后顾之忧
三、销售团队
定期组织员工进行*知识培训以及现场实勘
We focus on the development and production of medium and low voltage electrical components, and he an excellent product R & D team with 10 years of industry experience.
1、 R & D team
Every year, the company invests 10% of its revenue into R & D and technological innovation to ensure the priority of technology and products
2、 Technical team
Professional maintenance and after-sales technology has solved your worries
3、 Sales team
Regularly organize staff to carry out professional knowledge training and field survey
========DHMPS3-2I南京斯沃消防设备电源监控模块怎么接线图南京斯沃为您服务!=========
========DHMPS3-2I南京斯沃消防设备电源监控模块怎么接线图南京斯沃为您服务!=========