IC695AIG704
IC695AIG704 The ModuleBus Modem has an electrical and an optical Modulebus interface which are logically the same bus. A maximum of 12 I/O modules can be connected to the electrical ModuleBus and up to seven clusters can be connected to the fiber optic ModuleBus.
The fiber optic interface is intended for local distribution of I/O clusters and where more than 12 I/O modules are required in an I/O station.
Features and benefits
2 fiber optic ports to optical ModuleBus
ModuleBus (electrical) to the I/O Modules
Supervisory functions of I/O ModuleBus and power supply
Isolated power supply to I/O modules
TU840, MTU for redundant TB840/TB840A, dual ModuleBus
TU841, MTU for redundant TB840/TB840A, single ModuleBus
Input power fused
The Hydran M2 is a compact permanently mounted on-line transformer monitoring device that will
personnel to developing fault conditions. It continuously monitors a composite value of various fault gases (in ppm) or a Hydrogen gas only value (depending on sensor purchased). In addition it tracks moisture in oil (reading in %RH and ppm).
With additional sensors added, the Hydran M2 can also compute transformer mathematical models d on IEEE® and IEC® standards to provide further information on the performance of the transformer.Hydran M2是一种紧凑的*安装在线变压器监测装置,可提醒人员出现故障情况。它连续监测各种故障气体的合成值(ppm)或仅氢气值(取决于购买的传感器)。此外,它还跟踪油中的水分(读数为%RH和ppm)。
添加了额外的传感器后,Hydran M2还可以根据IEEE®和IEC®标准计算变压器数学模型,以提供关于变压器性能的进一步信息。Real-time Hydrogen or composite fault gas monitoring system
Moisture in oil measurement
Ability to integrate additional sensors (load, oil temperature, …)
Option to process transformer mathematical models d on IEC/IEEE standardsEasy to install on a single valve.
No moving parts, no pumps and no extra piping required.
No field calibration required.
Local and remote alarms set at pre defined levels.Hydrogen sensor responds * to Hydrogen (general fault gas)
Composite gas sensor responds * to Hydrogen and is also sensitive to Carbon Dioxide (overheated er insulation).
Choice of up to 4x input or output cards
Wide range of communication methods and protocols.
RS485 output is standard. TCP/IP copper or fibre is optional
Vacuum-resistant gas extraction membrane.
Built in temperature condition system.
Full system self test and self-diagnostics.
Logging of data and significant events up to a year.
User-friendly client/server graphical user interface software.
Applications
Medium to large sized transformers.
Lower risk and/or consequence of failure.
Transmission transformers.
Significant step up from manual oil sampling.实时氢气或复合故障气体监测系统
油中水分测量
能够集成附加传感器(负载、油温等)
基于IEC/IEEE标准处理变压器数学模型的选项易于安装在单个阀门上。
无需移动部件、泵和额外管道。
无需现场校准。
本地和远程警报设置在预先定义的水平。氢气传感器*响应氢气(一般故障气体)
复合气体传感器对氢气*响应,对二氧化碳(纸绝缘过热)也敏感。
*多可选择4个输入或输出卡
广泛的通信方法和协议。
RS485输出为标准输出。TCP/IP铜缆或光纤是可选的
耐真空气体抽取膜。