DPU90-AK 美国Omega

发布时间:2017-08-29
DPU90-AK 美国Omega由美国OMEGA原厂渠道的深圳市鑫博恒业优势提供,咨询热线 QQ:800062763 ,DPU90-AK 美国Omega质量可靠,精度高,是值得信赖的变送器

深圳市鑫博恒业科技有限公司

地址:深圳市福田区华强北都会大厦B座27楼S室

电话:     

http://www.xb5j.com  E-mail:info@xb5j.cn

QQ: 800062763

DPU90-AK

指示器,累加器,批量控制器和信号调节器 ? DPU91_FLOW
Multi-Parameter Input Transmitter
DPU91_FLOW

Large Auto-Sensing Backlit Display
“Dial-Style” Digital Bar Graph
Intuitive and “User-Friendly” Interface
Optional Field Upgradable Relays
Warning LED Indicator
Custom 13-Character Label Capabilities
Factory Reset CapabilityT

产品描述
The DPU91 transmitter provides a single channel interface for many different parameters including flow, pH/ORP, conductivity/resistivity, salinity and temperature. The DPU91-BC transmitter has the added capability of supporting the batch module for batching control. The extra-large (3.90 x 3.90") autosensing backlit display can be viewed at 4 to 5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a “dial-style” digital bar graph. The DPU91 is offered in both panel or field-mount versions. Both configurations can run on 12 to 32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs. Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include relay, direct conductivity/ resistivity, batch and a PC communications configuration tool. The unit can be used with default values for quick and easy programming or can be customized with labeling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.

Specifications
General
Input Channels: 1
Input Types: Digital serial ASCII, TTL level, 9600 bps
Frequency Range: 0.5 to 1500 Hz
Accuracy: 0.5% of reading (display)
Measurement Types: Flow, pH/ORP, conductivity/resistivity, salinity, pressure, temperature or batch
Enclosure and Display
Case Material: PBT
Window: Shatter-resistant glass
Keypad: 4 buttons, injection-molded silicone rubber seal
Display: Backlit, 7 and 14-segment
Update Rate: 1 second
LCD Contrast: 5 settings
Indicators: “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
Enclosure: ? DIN, NEMA 4X/IP65
Mounting Panel: ? DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included)
Field Mounts: Specified to Omega? field mount junction boxes
Weight: 0.63 kg (1.63 lb) DPU91-FLOW Series
Display Ranges For conductivity/resistivity version visit omega.com/dpu91_conductivity For pH/ORP version visit omega.com/ dpu91_ph
Flow Rate: -9999 to 99999 units per second, minute, hour or day
Totalizer: 0.00 to 99999999 units (program lockout or resettable)
Temperature: -99 to 350°C (-146 to 662°F)
Volume: 0 to 99999 cm3, m3, in3, ft3, gal, L, lb, kg, %
Environmental
Ambient Operating Temperature:
Backlit LCD: -10 to 70°C (14 to 158°F)
Storage Temperature: -15 to 70°C (5 to 158°F)
Relative Humidity: 0 to condensing for field mount; 0 to 95% non-condensing for panel mount
Maximum Altitude: 4000 m (13,123')
Electrical Requirements
Power to Sensors:
Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge
Input Power
DC: 10.8 to 35.2 Vdc, regulated
Current Output:
4 to 20 mA (10.8 to 35.2 VDC, 30 mA max)
DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc
DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc
Open Collector: 1
Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
Relay Specifications (DPU90-R optional)
Type: SPDT, Form C
Maximum Current Rating: 5 A resistive 50 mA DC
Maximum Voltage Rating: 30 Vdc or 250 Vac
Hysteresis Adjustable: Absolute in engineering units (EUs)
Latch Reset: In test screen only
Delay: 9999.9 seconds (maximum)
Test Mode: Set on/off
Cycle Time: 99999 seconds (maximum)
Maximum Pulse Rate: 400 pulses/minute
Proportional Pulse: 400 pulses/minute
Volumetric Pulse Width: 0.1 to 3200 s
Pulse Width Modulation: 0.1 to 320 s
Input Types
Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics (For pH models see omega.com/ dpu91_ph)
Conductivity/Resistivity: Input directly from OMEGA conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850 (For conductivity/resistivity models see omega.com/ dpu91_conductivity)
Input Specifications
Digital Serial: ACSII, TTL level, 9600 bps
Frequency Input:
Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency
Span: 0.5 Hz to 1500 Hz @ TTL level input
Accuracy: ± 0.5% or reading maximum error @ 25°C (77°F)
Repeatability: ±0.2% of reading
 

注: DPU91 and DPU91P come complete with operator’s manual.

产品编号  产品描述
  
DPU91 DC powered field mount multi-parameter display and transmitter (Requires FP90UM mounting kit)
  
DPU91P    DC powered panel mount multi-parameter display and transmitter
  
DPU91-BC  DC powered flow display and transmitter with batch control
Accessories
  
DPU90-AK  Angle adjustment kit for field mount
  
DPU90-BCM   Batch controller module
  
DPU90-COMM  Communications module, HART? protocol super imposes digital signal
  
DPU90-CT  PC configuration took, includes software
  
DPU90-R  programmable dual relay output module, SPDT form C, 5A resistive load
  
DPU90-WM  Wall mount accessory kit

FP90UM  Universal mounting bracket for field mounted units

FP90IM  Integral mount kit for use with FP8500 series paddlewheels

FPM-5000-LTCK  Liquid tight connector kit for wiring feed through
 

 DPU90-AK