CDSA-450

电导率和电阻率变送器及电极 ? DPU91_Conductivity
Multi-Parameter Input Transmitter For Conductivity, Resistivity and Salinity
DPU91_Conductivity

Large Auto-Sensing Backlit Display
“Dial-Style” Digital Bar Graph
Intuitive and “User-Friendly” Interface
Optional Field Upgradable Relays
Warning LED Indicator
Custom 13-Character Label Capabilities
Factory Reset Capability   

产品描述
The DPU91 transmitter provides a single channel interface for many different parameters including flow, pH/ORP, conductivity/resistivity, salinity and temperature. The DPU91-BC transmitter has the added capability of supporting the batch module for batching control. The extra-large (3.90 x 3.90") autosensing backlit display can be viewed at 4 to 5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a “dial-style” digital bar graph. The DPU91 is offered in both panel or field-mount versions. Both configurations can run on 12 to 32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs. Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include relay, direct conductivity/ resistivity, batch and a PC communications configuration tool. The unit can be used with default values for quick and easy programming or can be customized with labeling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.

Specifications
General
Input Channels: 1
Input Types: Digital serial ASCII, TTL level, 9600 bps
Frequency Range: 0.5 to 1500 Hz
Accuracy: 0.5% of reading (display)
Measurement Types: Flow, pH/ORP, conductivity/resistivity, salinity, pressure, temperature or batch
Enclosure and Display
Case Material: PBT
Window: Shatter-resistant glass
Keypad: 4 buttons, injection-molded silicone rubber seal
Display: Backlit, 7 and 14-segment
Update Rate: 1 second
LCD Contrast: 5 settings
Indicators: “Dial-style” digital bar graph, LEDs for open collector, relays and warning indicator
Enclosure: ? DIN, NEMA 4X/IP65
Mounting Panel: ? DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included)
Field Mounts: Specified to Omega? field mount junction boxes
Weight: 0.63 kg (1.38 lb)
Display Ranges
For PH/ORP version visit omega.com/dpu91_ph For flow version visit omega.com/ dpu91_flow
Conductivity: 0.0000 to 99999 μS, mS, PPM and PPB (TDS), kΩ, MΩ
Conductivity Temperature: -99 to 350°C (-146 to 662°F)
Temperature: -99 to 350°C (-146 to 662°F)
Salinity: 0 to 100 PPT
Environmental
Ambient Operating Temperature:
Backlit LCD: -10 to 70°C (14 to 158°F)
Storage Temperature: -15 to 70°C (5 to 158°F)
Relative Humidity: 0 to condensing for field mount; 0 to 95% non-condensing for panel mount
Maximum Altitude: 4000 m (13,123')
Electrical Requirements
Power to Sensors:
Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected
Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge
Input Power
DC: 10.8 to 35.2 Vdc, regulated
Current Output:
4 to 20 mA (10.8 to 35.2 VDC, 30 mA max)
Open Collector:1
Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection
Relay Specifications (DPU91-R)
Dry-Contact Relay:
Type: SPDT, Form C
Maximum Current Rating: 5 A resistive 50 mA DC
Maximum Voltage Rating: 30 Vdc or 250 Vac
Hysteresis Adjustable: Absolute in engineering units (EUs)
Latch Reset: In test screen only
Delay: 9999.9 seconds (maximum)
Test Mode: Set on/off
Cycle Time: 99999 seconds (maximum)
Maximum Pulse Rate: 400 pulses/minute
Proportional Pulse: 400 pulses/minute
Volumetric Pulse Width: 0.1 to 3200 s
Pulse Width Modulation: 0.1 to 320 s
Input Types
Digital or AC Frequency: pH/ORP input via the digital output from the PHTX-2750 pH/ORP sensor electronics for pH/ORP models visit omega.com/ dpu91_ph. For flow models visit omega.com/dpu91_flow
Raw Conductivity/Resistivity: Input directly from signet conductivity/ resistivity electrodes via direct conductivity/resistivity module or via CDTX-2850
Input Specifications
Digital Serial: ACSII, TTL level, 9600 bps
Frequency Input:
Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency
Span: 0.5 Hz to 1500 Hz @ TTL level input
Accuracy: ± 0.5% or reading maximum error @ 25°C (77°F)
Resolution: 1 μS
Repeatability: ±0.2% of reading

注: Comes complete with operator’s manual.

Sensors and mounting kits sold separately.

产品编号 产品描述

DPU91   DC powered field mount multi-parameter display and transmitter (Requires FP90UM universal mounting kit)
DPU91P   DC powered panel mount multi-parameter display and transmitter

Required Module for Conductivity

DPU90-C   Conductivity/Resistivity/Salinity direct input module (required for Conducitivty measurement)

Conductivity Sensors

CDCE-90-001   Conductivity sensor, 3?4 NPT, cell constant 0.01, 316 SS
CDCE-90-01   Conductivity sensor, 3?4 NPT, cell constant 0.01, 316 SS
CDCE-90-1   Conductivity sensor, 3?4 NPT, cell constant 1, 316 SS
CDCE-90-10   Conductivity sensor, 3?4 NPT, cell constant 10, 316 SS
CDCE-90-20B   Conductivity sensor, 3?4 NPT, cell constant 20, 316 SS, PEEK
CDCE-90S-001-S15   Conductivity sensor, 1?2" sanitary, cell constant 0.01, 316 SS
CDCE-90S-001-T15   Conductivity sensor, 1" sanitary, cell constant 0.01, Titanium
CDCE-90S-01-S20   Conductivity sensor, 2" sanitary, cell constant 0.1, 316 SS
CDCE-90S-1-S15   Conductivity sensor, 11?2" sanitary, cell constant 1, 316 SS
CDCE-90S-1-S20   Conductivity sensor, 2" sanitary, cell constant 1, 316 SS

Accessories
DPU90-AK   Angle adjustment kit for field mount
DPU90-COMM   Communications module, HART?
DPU90-CT   PC configuration tool, includes software
DPU90-R   Programmable dual relay output module

Mounting Options

FP90UM Universal mounting bracket for field mounted units

Conductivity Solutions

CDSA-10  *10 μ/cm conductivity solution
CDSA-15  *15 μ/cm conductivity solution
CDSA-45  45 μ/cm conductivity solution
CDSA-450  450 μ/cm conductivity solution
CDSA-1413  1413 μ/cm conducitivity solution
CDSA-1500  1500 μ/cm conducitivity solution
CDSA-4500  4500 μ/cm conductivity solution
CDSA-45000  4500 μ/cm conductivity solution
 

产品编号
DPU91  
DPU91P 

DPU90-C 

CDCE-90-001  
CDCE-90-01  
CDCE-90-1 
CDCE-90-10  
CDCE-90-20B  
CDCE-90S-001-S15 
CDCE-90S-001-T15  
CDCE-90S-01-S20 
CDCE-90S-1-S15 
CDCE-90S-1-S20 

DPU90-AK  
DPU90-COMM  
DPU90-CT  
DPU90-R  

FP90UM

CDSA-10
CDSA-15
CDSA-45 
CDSA-450 
CDSA-1413
CDSA-1500 
CDSA-4500 
CDSA-45000

CDSA-450

CDSA-450

 

 