OM-CP-HITEMP140X2-TD-PT-5

发布时间:2017-09-07
OM-CP-HITEMP140X2-TD-PT-5记录器咨询热线 QQ:800062763深圳市鑫博恒业科技有限公司,OM-CP-HITEMP140X2-TD-PT-5记录器由美国OMEGA原厂渠道的深圳市鑫博恒业优势提供,美国OMEGA OM-CP-HITEMP140X2-TD-PT-5质量可靠,精度高,是值得信赖的记录器

深圳市鑫博恒业科技有限公司

地址:深圳市福田区华强北都会大厦B座27楼S室

电话:     

http://www.xb5j.com  E-mail:info@xb5j.cn

QQ: 800062763

OM-CP-HITEMP140X2-TD-PT-5

数据采集 » » OM-CP-HITEMP140-FR
High Temperature Data Logger With 50 mm (2") Fast Response Probe
OM-CP-HITEMP140-FR

Fast Response Time
Operating Temperature Range: -40 to 140°C (-40 to 284°F)
Optional Vented or Flush Thermal Shield for Operation up to 250°C (482°F)
Probe Measures from -200 to 260°C (-328 to 500°F)
±0.1°C (±0.18°F) Accuracy
Submersible (IP68)
Trigger Settings
Programmable Start and Stop Time
4 Hz Reading Rate

产品描述
The OM-CP-HITEMP140-FR is a high temperature data logger with an ultra-fast response time to record temperature during rapidly changing thermal processes. This high temperature data logger features a 50 L x 1.59 mm dia (2 x 0.0625") probe and is capable of recording up to 4 Hz, which is 4 times faster than other data loggers in this class. This allows the temperature sensor to quickly adapt and accurately record temperature variations in changing environments. Applications include oven profiling, steam sterilization, autoclave verification and mapping, seafood processing, flash freezing and more.

The OM-CP-HITEMP140-FR data logger is designed with food grade stainless steel. The device can be placed in environments up to 140°C (284°F) and the probe is capable of measuring from -200 to 260°C (-328 to 500°F). The OM-CP-HITEMP140-FR is also available with an optional thermal shield enclosure to extend the operating range of the data logger to -200 to 250°C (-328 to 482°F). The OM-CP-HITEMP140-FR-TSK (Thermal Shield Kit) comes with either a vented or flush top enclosure to accommodate a multitude of applications.

The Trigger Settings feature of the OM-CP-HITEMP140-FR allows users to configure high and low temperature thresholds that when met or exceeded, will automatically start or stop recording data to memory. This data logger is capable of storing up to 32,700 date and time stamped readings and features a nonvolatile solid state memory which retains data even if the battery becomes discharged.

The OM-CP-MULTIMOUNT-Z is a versatile mount or stand for use with the OM-CP-HITEMP140 series of data loggers. It can be used to stabilize a logger inside an autoclave, or screwed to a flat surface to create an anchored . Made of 316 stainless steel, the OM-CP-MULTIMOUNT-Z is able to withstand temperatures up to 150°C (302°F) making it ideal for use in autoclave sterilization processes.

The OM-CP-HITEMP140-FR utilizes the latest software. Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.

SPECIFICATIONS
OM-CP-HITEMP140-FR
(DATA LOGGER WITHOUT THERMAL SHIELD)
TEMPERATURE
Temperature Sensor: 100 Ω platinum RTD
Probe Measurement Range: -200 to 260°C (-328 to 500°F)
Temperature Resolution: 0.01°C (0.02°F)
Calibrated Accuracy: ±0.1°C (±0.18°F) 20 to 140°C (68 to 284°F)

GENERAL
Data Logger Response Time (Hours: Minutes: Seconds: Fractions of a Second):
In Air:
t60 - 00:00:39:00 (39 sec to reach 60% of step change)
t90 - 00:02:71:00 (2 min 71 sec to reach 90% of step change)
In Water:
t60 - 00:00:10:00 (10 sec to reach 60% of step change)
t90 - 00:00:12:00 (12 sec to reach 90% of step change)
Reading Rate: 4 readings per second up to 1 reading every 24 hours
Memory: 32,767 readings
Start Modes:
• Software programmable immediate start
• Delay start up to 18 months in advance
Stop Modes: Manual or timed (specific date and time)
Trigger Settings: High and low limits may be set. Once data meets or exceed sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number of readings to take after the device triggers
Readings in Trigger Settings Mode: 10,922 readings
Real Time Recording: May be used with PC to monitor and record data in real time
Password Protection: An optional password may be programmed into the device to restrict access to configuration options. Data may be read without the password
Memory Wrap Around: Yes
Battery Type: 3.6V high-temperature lithium battery included; user replaceable
Battery Life: 2 years typical (1 minute reading rate)
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Data Format: Date and time stamped °C, °F, °R, K
Time Accuracy: ±1 minute/month at 25°C (77°F)
Extended Operation: ±20 minutes/month at 140°C (284°F)
Computer Interface: OM-CP-IFC400 USB docking station or OM-CP-IFC406 multiplexer interface required; 125,000 baud
Software: Windows® XP, SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment: -40 to 140°C (-40 to 284°F), 0 to RH, 0.002 to 100 PSIA
IP Rating: IP68
Dimensions (Body): 48 H x 24.6 mm D (1.89 x 0.970")
Dimensions (Probe): 44.5 L x 1.59 mm dia (1.75 x 0.0625"); 4.78 mm transitional dia (0.188")
Weight: 65 g (2.3 oz)
Materials: 316 Stainless Steel, PEEK

注: Comes complete with 3.6V lithium battery. Operator’s manual and USB interface cable are included with the OM-CP-IFC400 software/cable package or OM-CP-IFC406 multiplexer (required for data logger operation, sold separately).

产品编号  产品描述
  
OM-CP-HITEMP140-FR   High temperature data logger with 50 mm (2") fast response probe

  
OM-CP-HITEMP140-FR-CERT    High temperature data logger with a 50 mm (2") fast response probe and NIST calibration certificate

  
OM-CP-HITEMP140-FR-TSK    OM-CP-HITEMP140-FR data logger and vented thermal shield

  
OM-CP-HITEMP140-FR-TSK-CERT   OM-CP-HITEMP140-FR data logger and vented thermal shield and NIST calibration certificate

  
OM-CP-HITEMP140-FR-TSK-FL    OM-CP-HITEMP140-FR data logger and flush top thermal shield

  
OM-CP-HITEMP140-FR-TSK-FL-CERT    OM-CP-HITEMP140-FR data logger and flush top thermal shield and NIST calibration certificate

Accessories

OM-CP-IFC400   Docking station (for single data logger) with USB cable, software and manual

  
OM-CP-IFC406   Multiplexer data logger interface (accepts up to 6 data loggers) with USB cable, software and manual


OM-CP-BAT110   Replacement 3.6V high temperature lithium battery

  
OM-CP-MULTIMOUNT-Z   Mount/stand for OM-CP-HITEMP140 series data loggers

  
OM-CP-SVP-SYSTEM    FDA 21 CFR part 11 compliant IQ/OQ/PQ secure software validation workbook and software package (unlimited users, license per computer)
 

产品型号
OM-CP-HITEMP140
OM-CP-HITEMP140-1
OM-CP-HITEMP140-1-CERT
OM-CP-HITEMP140-5.25
OM-CP-HITEMP140-5.25-CERT
OM-CP-HITEMP140-5.25-TSK
OM-CP-HITEMP140-5.25-TSK-CERT
OM-CP-HITEMP140-7
OM-CP-HITEMP140-7-CERT
OM-CP-HITEMP140-7-TSK
OM-CP-HITEMP140-7-TSK-CERT
OM-CP-HITEMP140-CERT
OM-CP-HITEMP140-FP-36
OM-CP-HITEMP140-FP-36-CERT
OM-CP-HITEMP140-FP-36-TSK
OM-CP-HITEMP140-FP-36-TSK-CERT
OM-CP-HITEMP140-FP-36-TSK-FL
OM-CP-HITEMP140-FP-36-TSK-FL-C
OM-CP-HITEMP140-FP-72
OM-CP-HITEMP140-FP-72-CERT
OM-CP-HITEMP140-FP-72-TSK
OM-CP-HITEMP140-FP-72-TSK-CERT
OM-CP-HITEMP140-FP-72-TSK-FL
OM-CP-HITEMP140-FP-72-TSK-FL-C
OM-CP-HITEMP140-FR
OM-CP-HITEMP140-FR-CERT
OM-CP-HITEMP140-FR-TSK
OM-CP-HITEMP140-FR-TSK-CERT
OM-CP-HITEMP140-FR-TSK-FL
OM-CP-HITEMP140-FR-TSK-FL-CERT
OM-CP-HITEMP140-M12
OM-CP-HITEMP140-M12-CERT
OM-CP-HITEMP140-O-RING
OM-CP-HITEMP140-PT-1
OM-CP-HITEMP140-PT-1-CERT
OM-CP-HITEMP140-PT-1-TSK
OM-CP-HITEMP140-PT-1-TSK-CERT
OM-CP-HITEMP140-PT-5
OM-CP-HITEMP140-PT-5-CERT
OM-CP-HITEMP140-PT-5-TSK
OM-CP-HITEMP140-PT-5-TSK-CERT
OM-CP-HITEMP140-TS
OM-CP-HITEMP140-TSK
OM-CP-HITEMP140-TSK-CERT
OM-CP-HITEMP140X2-FP-72
OM-CP-HITEMP140X2-FP-72-CERT
OM-CP-HITEMP140X2-FP-72-PT-1
OM-CP-HITEMP140X2-FP-72-PT-1CT
OM-CP-HITEMP140X2-FP-72-PT-5
OM-CP-HITEMP140X2-FP-72-PT-5CT
OM-CP-HITEMP140X2-TD-FP-72
OM-CP-HITEMP140X2-TD-FP-72-CT
OM-CP-HITEMP140X2-TD-PT-1
OM-CP-HITEMP140X2-TD-PT-1-CERT
OM-CP-HITEMP140X2-TD-PT-5
OM-CP-HITEMP140X2-TD-PT-5-CERT
OM-CP-HITEMP150
OM-CP-HITEMP150-FP
OM-CP-HITEMP150-PT-CERT
OM-CP-HITEMP150-TS
OM-CP-HITEMP150-TSK-CERT
OM-CP-IFC400
OM-CP-IFC406
OM-CP-BAT110
OM-CP-MULTIMOUNT-Z
OM-CP-SVP-SYSTEM
OM-CP-IFC400  
OM-CP-IFC406 
OM-CP-BAT110   
OM-CP-MULTIMOUNT-Z   
OM-CP-SVP-SYSTEM  
 

OM-CP-HITEMP140X2-TD-PT-5

OM-CP-HITEMP140X2-TD-PT-5

 

 

上一篇:徐州市施耐德电气授权代理商
下一篇:THERMOREGTHERMO...