Configuration

The following electronic configuring aids and engineering tools are available for SINAMICS G120C compact inverters:

Drive Technology Configurator (DT Configurator) within the CA 01

The interactive catalog CA 01 – the offline Industry Mall of Siemens on DVD‑ROM – contains over 100 000 products with approximately 5 million possible drive system product variants. The Drive Technology Configurator (DT Configurator) has been developed to facilitate selection of the correct motor and/or inverter from the wide spectrum of drives. It is integrated in Catalog CA 01 as an add-on on DVD‑ROM.

Online DT Configurator

In addition, the DT Configurator can be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Industry Mall at the following address: 
http://www.siemens.com/dt-configurator

SIZER for Siemens Drives engineering tool

The SIZER for Siemens Drives engineering tool makes it easy to engineer the SINAMICS drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER for Siemens Drives is designed to support configuring of the entire drive system.

You can find further information on the SIZER for Siemens Drives engineering tool in the chapter Engineering tools.

The SIZER for Siemens Drives engineering tool is available free on the Internet at 
http://www.siemens.com/sizer

STARTER commissioning tool

The STARTER commissioning tool allows menu-ed commissioning, optimization and diagnostics. Apart from the SINAMICS drives, STARTER is also suitable for MICROMASTER 4 devices.

You can find further information about the STARTER commissioning tool in the chapter Engineering tools.

Additional information about the STARTER commissioning tool is available on the Internet at 
http://www.siemens.com/starter

SINAMICS Startdrive commissioning tool

SINAMICS Startdrive is a tool for configuring, commissioning, and diagnosing the SINAMICS family of drives and is integrated into the TIA Portal. SINAMICS Startdrive can be used to implement drive tasks with the SINAMICS G110M, SINAMICS G120, SINAMICS G120C, SINAMICS G120D and SINAMICS G120P inverter series. The commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives.

You can find further information on the SINAMICS Startdrive commissioning tool in the chapter Engineering tools.

The SINAMICS Startdrive commissioning tool is available free on the Internet at 
http://www.siemens.com/startdrive

Drive ES engineering system

Drive ES is the engineering system that can be used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. Two software packages are available for SINAMICS – Drive ES Basic and Drive ES PCS.

You can find further information about the Drive ES engineering system in the chapter Engineering tools.

Additional information about the Drive ES engineering system is available on the Internet at 
http://www.siemens.com/drive-es

Technical specifications

Unless explicitly specified otherwise, the following technical specifications are valid for all SINAMICS G120C compact converters.

General technical specifications

Mechanical specifications

Vibratory load

 

  • Transport acc. to EN 60721‑3‑2 1)

Class 1M2

  • Operation acc. to EN 60721‑3‑3

Class 3M1

Shock load

 

  • Transport acc. to EN 60721‑3‑2 1)

Class 1M2

  • Operation acc. to EN 60721‑3‑3

Class 3M2

Degree of protection

IP20/ UL open type

Permissible mounting position

Vertical wall mounting

Ambient conditions

Protection class

According to EN 61800‑5‑1

Class III (PELV1)

Touch protection

According to EN 61800‑5‑1

Class I (with protective conductor system)

Humidity, max.

95 % at 40 °C (104 °F), condensation and icing not permissible

Ambient temperature

 

  • Storage 1) acc. to EN 60068‑2‑1

-40 ... +70 °C (-40 ... +158 °F)

  • Transport 1) acc. to EN 60068‑2‑1

-40 ... +70 °C (-40 ... +158 °F)

  • Operation acc. to EN 60068‑2‑2

-10 ... +40 °C (14 ... 104 °F) without derating

>40 ... 60 °C (104 ... 140 °F) see derating characteristics

Environmental class in operation

 

  • Harmful chemical substances

Class 3C2 to EN 60721‑3‑3

  • Organic/biological pollutants

Class 3B1 to EN 60721‑3‑3

  • Degree of pollution

2 acc. to EN 61800

Standards

Compliance with standards

CE, UL, cUL, C-Tick (RCM)

Fail-safe certification

Function: Safe Torque Off (STO)

  • According to IEC 61508

SIL 2

  • According to EN ISO 13849‑1

PL d and Category 3

CE marking, according to

EMC Directive 2004/108/EC

Low-Voltage Directive 2006/95/EC

EMC Directive 2)

According to EN 61800‑3

 

Interference immunity

The SINAMICS G120C compact inverters are tested according to the interference immunity requirements for environments according to Category C3.

Interference emissions

 

  • Frame sizes FSAA to FSC
    without integrated line filter

3)

  • Frame sizes FSAA to FSC
    with integrated line filter class A

The inverters comply with the limit values according to Category C3.

The inverters comply with the limit values for conducted interference and field-conducted interference emissions according to Category C2. 4) 5)

 

Note:

The EMC product standard EN 61800-3 does not apply directly to a frequency converter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the converter. The frequency inverters on their own do not generally require identification according to the EMC Directive.


1) In transport packaging.

2) For further general information, see also chapter SINAMICS G120, section Technical specifications, Compliance with standards.

3) Non-filtered devices are designed for operation in IT systems or in conjunction with an RCD. The customer must provide suitable RI suppression equipment to ensure that these devices comply with the limits defined for Category C3 or C2.

4) Max. permissible motor cable length of 25 m (82 ft) (shielded) as standard - with low-capacitance CY cable for sizes FSA and FSB 50 m (164 ft) (shielded), for FSC 100 m (328 ft) (shielded).

5) SINAMICS G120C compact inverters, size FSB, with PROFINET interface (Article No.: 6SL3210-1KE21-.AF1) additionally require a line reactor.

 

SINAMICS G120C compact inverter

USS, Modbus RTU version

PROFIBUS DP version

PROFINET, EtherNet/IP version

 

6SL3210-1KE..-..B1
6SL3210-1KE..-..B2

6SL3210-1KE..-..P1
6SL3210-1KE..-..P2

6SL3210-1KE..-..F1
6SL3210-1KE..-..F2

Integrated bus interface

Fieldbus protocols

  • USS
  • Modbus RTU
    (switchable using a parameter)

PROFIBUS DP

  • PROFINET
  • EtherNet/IP
  • ODVA AC/DC drive
  • SINAMICS profiles

Profile

  • PROFIdrive Profile V4.1
  • PROFIsafe
  • PROFIdrive Profile V4.1
  • PROFIsafe
  • PROFIenergy

Hardware

Plug-in terminal, insulated,
USS: max. 187.5 kBaud
Modbus RTU: 19.2 kBaud,
Bus terminating resistor that can be switched in

9-pin SUB-D socket, insulated,
max. 12 Mbit/s
Slave address can be set using DIP switches

2 × RJ45, max. 100 Mbit/s (full duplex), device name can be stored on the device

I/O interfaces

Signal cable cross-section

0.15 ... 1.5 mm2 (28 ... 16 AWG)

Digital inputs – Standard

6 isolated inputs

Optically isolated;
Free reference potential (own potential group)
NPN/PNP logic can be selected using the wiring

  • Switching level: 0 → 1

11 V

  • Switching level: 1 → 0

5 V

  • Input current, max.

15 mA

Digital inputs, fail-safe

1

When using the standard digital inputs (DI4+DI5)
Safety function: Safe Torque Off (STO)

Digital outputs

1 relay changeover contact
30 V DC, 0.5 A (ohmic load)

1 transistor
30 V DC, 0.5 A (ohmic load)

Analog inputs

1 analog input

Differential input
Switchable between voltage (-10 ... +10 V) and current (0/4 ... 20 mA) using a DIP switch
10‑bit resolution
Can be used as additional digital input

Analog inputs are protected in a voltage range of ± 30 V and have a common-mode voltage in the ± 15 V range.

  • Switching threshold: 0 → 1

4 V

  • Switching threshold: 1 → 0

1.6 V

Analog outputs

1 analog output

Non-isolated output
Switchable between voltage (0 ... 10 V) and current (0/4 ... 20 mA) using a parameter
Voltage mode: 10 V, min. burden 10 kΩ
Current mode: 20 mA, max. burden 500 Ω

The analog outputs have short-circuit protection

PTC/KTY interface

1 motor temperature sensor input

Connectable sensors PTC, KTY and bil,
Accuracy ±5 °C (41 °F)

Voltage supply for the integrated Control Unit

24 V DC via the Power Module or by connecting to an external 20.4 ... 28.8 V DC power supply

Typical input current: 500 mA at 24 V DC

Tool interfaces

Memory card

Optional
SINAMICS SD card

Operator panels

Optional
Basic Operator Panel BOP‑2 or Intelligent Operator Panel IOP

PC interface

USB


 

SINAMICS G120C compact inverter

Open-loop/closed-loop control techniques

U/f linear/quadratic/parameterizable

✓ 

U/f with flux current control (FCC)

✓ 

U/f ECO; linear/quadratic

✓ 

Vector control, sensorless

✓ 

Vector control, with sensor

Torque control, sensorless

Torque control, with sensor

Software functions

Setpoint input

✓ 

Fixed frequencies

16, parameterizable

JOG

✓ 

Digital motorized potentiometer (MOP)

✓ 

Ramp smoothing

✓ 

Extended ramp-function generator (with ramp smoothing Off3)

✓ 

Positioning down ramp

Slip compensation

✓ 

Signal interconnection with BICO technology

✓ 

Free function blocks (FFB)

for logical and arithmetic operations

Switchable drive data sets (DDS)

✓ (2)

Switchable command data sets (CDS)

✓ (2)

Flying restart

✓ 

Automatic restart

after line supply failure or operating fault (AR)

✓ 

Technology controller (internal PID)

✓ 

Energy consumption counter

✓ 

Energy saving computer

✓ 

Thermal motor protection

✓ (I2t, sensor: PTC, KTY and bil)

Thermal inverter protection

✓ 

Motor identification

✓ 

Motor holding brake

✓ 

Auto-ramping (Vdcmax controller)

✓ 

Kinetic buffering (Vdcmin controller)

✓ 

Braking functions

 

  • DC braking

✓ 

  • Compound braking

✓ 

  • Dynamic braking with integrated braking chopper

✓ 


 

General technical specifications of the power electronics

System operating voltage

380 ... 480 V 3 AC +10 % -20 %

Grid requirement
Short-circuit power RSC

No restriction

Input frequency

47 ... 63 Hz

Output frequency

 

  • Control mode U/f

0 ... 550 Hz

  • Control type Vector

0 ... 240 Hz

Pulse frequency

4 kHz
for higher pulse frequencies up to 16 kHz, see derating data

Power factor λ

0.7 ... 0.85

Offset factor cos φ

≥0.95

Output voltage, max.

as % of input voltage

95 %

Overload capability

 

  • Low overload LO
    Note:
    No reduction in -load current IL for use of overload.

1.5 × -load current IL (i. e. 150 % overload) for 3 s plus
1.1 × -load current IL (i. e. 110 % overload) for 57 s within a cycle time of 300 s

  • High overload HO
    Note:
    No reduction in -load current IH for use of overload.

2 × -load current IH (i. e. 200 % overload) for 3 s plus
1.5 × -load current IH (i. e. 150 % overload) for 57 s within a cycle time of 300 s

Electromagnetic compatibility

  • Devices without line filter 1)
  • Devices with integrated line filter class A according to EN 55011

Cooling

Air cooling using an integrated fan

Installation altitude

Up to 1000 m (3281 ft) above sea level without derating,
> 1000 m (3281 ft) see derating characteristics

Short Circuit Current Rating (SCCR) 2), max. acc. to UL

100 kA See recommended line-side components – the value depends on the fuses and circuit breakers used

Protection functions

  • Undervoltage
  • Overvoltage
  • Overload
  • Ground fault
  • Short-circuit
  • Stall protection
  • Motor blocking protection
  • Motor overtemperature
  • Converter overtemperature

北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU北京回收西门子NCU