美国Omega OM-DAQXL-2-KR美国OMEGA,咨询热线 深圳市鑫博恒业科技有限公司,美国OMEGA 美国Omega OM-DAQXL-2-KR由美国OMEGA原厂渠道的深圳市鑫博恒业优势提供,美国OMEGA 美国Omega OM-DAQXL-2-KR质量可靠,精度高,是值得信赖的记录仪

深圳市鑫博恒业科技有限公司

地址:深圳市福田区华强北都会大厦B座27楼S室

电话:     

http://www.xb5j.com  E-mail:info@xb5j.cn

QQ: 800062763

OM-DAQXL-2-KR

数据采集 » » OM-DAQXL Series
8 or 16 Channel Universal Input Touch Screen Data Loggers

7" Touch Screen TFT Display
8 (OM-DAQXL-1) or 16 (OM-DAQXL-2) Analog Channel Inputs
8 or 16 Virtual (Math) Channels
8 Digital I/O (4 Inputs, 4 Outputs)
Measures Voltage, Current, Thermocouples, RTDs, Thermistors, Strain Gage, Frequency and Pulse
24-Bit Analog Input Resolution
Fast Sampling Rate–125 Samples/Sec (1 Channel)
4 Alarm Outputs
Large Data Storage: 1 GB Internal Memory, 32 GB SD Card or 32 GB USB Drive
USB Device (PC Communication) and USB Host (USB Drive, Mouse, etc.)
Powers from Rechargeable Lithium-Ion Battery and/or AC Adaptor
Protective Rubber Boot - Comes with Hard carrying case
Benchtop or Wall Mount Enclosure Design

产品描述
OM-DAQXL is an 8 or 16 channel analog input portable data logger with a 7 inch resistive touch color display. All inputs are programmable and can be configured for millivolts, volts, milliamps, thermocouple, RTD, thermistor, strain gauge, or frequency. All the menus, selections, and configurations can be done from the display touch screen. The unit also has 4 digital inputs, 4 digital outputs, 4 alarm outputs, one USB host port and one USB device port. The unit also has 3 LEDs for different indications (Power, Alarm and Logging).

The OM-DAQXL comes complete with protective rubber boot, rechargeable lithium ion battery, 32 GB SD card, one plastic stylus, 1 GB USB thumb drive, 1.8 m (6') USB cable, 1.8 m (6') digital I/O cable, alarm/excitation terminal block, universal AC adaptor, screwdriver, quick start guide, set of 5 PTFE insulated Type K thermocouples, set of 5 ferrites to install on the thermocouple inputs (for noise reduction) and crimp-on ground lug. The unit can be wall mounted using the provided keyhole mount or operated on a bench using the tilt stand.

Home Screen
The home screen is the main screen of the data logger’s user interface. It is divided into 3 distinct sections as shown on the PDF.

Digital Display View
Status/Information Display: This status bar provides information such as Battery Charge percentage, System Clock (displays current Time & Date), Lock/Unlock data logger, status of the 4 Alarm Outputs, and Logging Mode indication.

Data Display Area: This is the area where different inputs (up to 4 Channels) are displayed vs. time. The data is displayed in 4 different ways: Waveform, Waveform & Table, Table only, and Digital. In the Digital view, each channel name and number are displayed along with the value.

Navigation Toolbar: This toolbar provides access to all the functions and menus of the data logger. You can extend or retract the toolbar by pressing the Tool button. The following flow chart shows all the functionalities of the buttons of the toolbar.

Standalone Operation
The OM-DAQXL’s touch screen user interface (UI) makes configuring the data logger for operation straight forward and simple. Recorded data files can easily be reviewed and analyzed on the OM-DAQXL. For data analysis on a computer, simply transfer the data file from the SD card or USB thumb drive to the PC and open the selected data file into Excel® or other data analysis software.

SPECIFICATIONS
Screen: 7 inch, TFT, resistive touch comes with plastic stylus
Rubber Boot: Black
Analog Input Type: Thermocouple, thermistor, RTD, strain gauge, DC voltage, DC current
Thermocouple Types: J, K, T, E, R, S, B, C, N
Thermocouple Accuracy:
Type J or K: ±(0.15% of rdg + 1.1°C)
Type T, E or N: ±(0.15% of rdg + 1.7°C)
Type R, S, B or C: ±(0.15% of rdg + 2.0°C)
RTD Types: Pt100, Pt500, Pt1000 (0.00385 or 0.00392 curve); 2, 3 or 4-wire
RTD Accuracy: ±(0.25% of rdg + 1°C)
Thermistor Types: 2252Ω/10KΩ
Thermistor Accuracy: ±1.0°C
DC Voltage Input Ranges: ±50 mV, ±100 mV, ±1V, ±5V, ±10V, ±20V, ±50V
DC Current Input Range: ±20 mA
DC Voltage/Current Accuracy: ±0.1% of FS
Strain Gauge Type: 100Ω full bridge, 350Ω full bridge
Strain Gauge Excitation: 5V, 10V

Digital Input Type: Pulse/Frequency
Frequency/Pulse Input: 0 to 250 KHz
Frequency Accuracy: ±2 Hz

Sampling Rate: 125 s/sec (Max) to 1 s/hour (Min)
Maximum Sampling Rate per Number of Channels (Analog and Digital):
1 Channel: 125 s/sec
2 Channels: 50 s/sec
4 Channels: 25 s/sec
8 Channels: 10 s/sec
16 Channels: 5 s/sec
Logging Rate: 125 s/sec (Max) to 1 s/hour (Min)
Maximum Logging Rate per Number of Channels (Analog and Digital):
1 Channel: 125 s/sec
2 Channels: 50 s/sec
4 Channels: 25 s/sec
8 Channels: 10 s/sec
16 Channels: 5 s/sec

Excitation to Power External Transmitter: 24 Vdc @ 50 mA output–set in data session setting
Filter Options: Per channel selectable moving average filter: None, 2, 5, 10, 20 or 100 samples
Number of Samples for Moving Average Filter per Channel: Up to 50 samples
Math (Virtual) Channels: 8 or 16
Digital Inputs: 4 Schmitt trigger d inputs
Range: 0 to 24 Vdc single-ended
Logic High Threshold: 2.5V
Logic Low Threshold: 1.5V
Digital Outputs: 4 channels, open collector, 5V @ 50 mA
Alarm Output: 4, Open collector, 30V @ 500 mA
Alarms per Channel: Two
Alarm Types: High, low, windows in, windows out, open sensor
Alarm Latching: Settable in alarm menu
On Alarm Event: Map to 4 alarm outputs, take screen shot, sound buzzer
Logging Conditions: On command or d on trigger conditions
Start and Stop Trigger Conditions: Timer, date and time, weekday and time, alarm output, external trigger
Memory:
Internal: 1 GB
SD Card: 32 GB
USB Drive: 32 GB
USB Ports: One host and one device
Battery: Rechargeable lithium-ion; 7.2V @ 4.8 Ah
Battery Life: 4 to 8 hours d on display setting
DC Adaptor: 12 Vdc @ 5A
Operating Environment: 0 to 50°C (32 to 122°F), 0 to 95%RH non-condensing
General Dimensions: 28.6 L x 15.24 H x 6.35 cm D (9 x 6 x 2.5")
Weight: 1.13 kg (2.5 lbs)


产品编号  产品描述
  
OM-DAQXL-1-NA-CAL-3 8-channel touch screen data logger with USB communications and CAL-3 NIST calibration certificate for type K thermocouple input, deg C (see Note 2 below To Order table)

  
OM-DAQXL-2-NA-CAL-3 16-channel touch screen data logger with USB communications and CAL-3 NIST calibration certificate for type K thermocouple input, deg C (see Note 2 below To Order table)

  
OM-DAQXL-1-NA-CAL-4 8-channel touch screen data logger with USB communications and CAL-4 NIST calibration certificate for user-specified input type and units (see Note 2 below To Order table)

  
OM-DAQXL-2-NA-CAL-4 16-channel touch screen data logger with USB communications and CAL-4 NIST calibration certificate for user-specified input type and units (see Note 2 below To Order table)

  
OM-DAQXL-1-SEA 8-channel touch screen data logger with USB communications

  
OM-DAQXL-2-SEA 16-channel touch screen data logger with USB communications

Accessories
  
OM-DAQXL-RB Spare rubber boot

  
SD32GB Spare 32 GB SD card

  
OM-DAQXL-USB Spare USB cable, 1.8 m (6')

  
OM-DAQXL-CABLE6 Spare digital I/O cable, 1.8 m (6')

  
OM-DAQXL-TB8 Spare alarm/excitation terminal block


5TC-TT-K-20-36 Spare set of 5 Type K thermocouples with stripped leads

  
PT-USB-1 Spare 1 GB thumb drive

  
OM-DAQXL-RF Spare ferrite for thermocouple input

  
OM-DAQXL-ADAPTOR-SEA Spare 12 Vdc, 5A power adaptor for Singapore

  
OM-DAQXL-BATTERY Spare rechargeable battery pack

  
OM-DAQXL-STYLUS Spare stylus


注: (1) The OM-DAQXL comes complete with protective rubber boot, rechargeable lithium ion battery, 32 GB SD card, one plastic stylus, 1 GB USB thumb drive, 1.8 m (6') USB cable, 1.8 m (6') digital I/O cable, alarm/excitation terminal block, universal AC adaptor, screwdriver, quick start guide, set of 5 PTFE insulated Type K thermocouples, set of 5 ferrites to install on the thermocouple inputs (for noise reduction) and crimp-on ground lug, and a Hard carrying case. The unit can be wall mounted using the provided keyhole mount or operated on a bench using the tilt stand.

(2) OM-DAQXL-1-NA-CAL-3 and OM-DAQXL-2-NA-CAL-3 data loggers include a NIST calibration certificate for default input Type K thermocouple with readings in deg C. To order a data logger with NIST calibration certificate for any other input type/units (other than the default input type K, deg C), select OM-DAQXL-1-NA-CAL-4 or OM-DAQXL-2-NA-CAL-4 and specify the desired input type and units.
 

======

OM-DAQXL-1-BR
OM-DAQXL-1-CN
OM-DAQXL-1-EU
OM-DAQXL-1-JP
OM-DAQXL-1-KR
OM-DAQXL-1-MX
OM-DAQXL-1-NA
OM-DAQXL-1-NA-CAL-3
OM-DAQXL-1-NA-CAL-4
OM-DAQXL-1-SAA
OM-DAQXL-1-SEA
OM-DAQXL-1-SN
OM-DAQXL-1-UK
OM-DAQXL-2-BR
OM-DAQXL-2-CN
OM-DAQXL-2-EU
OM-DAQXL-2-JP
OM-DAQXL-2-KR
OM-DAQXL-2-MX
OM-DAQXL-2-NA
OM-DAQXL-2-NA-CAL-3
OM-DAQXL-2-NA-CAL-4
OM-DAQXL-2-SAA
OM-DAQXL-2-SEA
OM-DAQXL-2-SN
OM-DAQXL-2-UK
OM-DAQXL-ADAPTOR-BR
OM-DAQXL-ADAPTOR-CN
OM-DAQXL-ADAPTOR-EU
OM-DAQXL-ADAPTOR-JP
OM-DAQXL-ADAPTOR-KR
OM-DAQXL-ADAPTOR-MX
OM-DAQXL-ADAPTOR-NA
OM-DAQXL-ADAPTOR-SAA
OM-DAQXL-ADAPTOR-SEA
OM-DAQXL-ADAPTOR-SN
OM-DAQXL-ADAPTOR-UK
OM-DAQXL-BATTERY
OM-DAQXL-CABLE6
OM-DAQXL-RB
OM-DAQXL-RF
OM-DAQXL-STYLUS
OM-DAQXL-TB8
OM-DAQXL-USB

 

 OM-DAQXL-2-KR

美国Omega OM-DAQXL-2-KR

 

 

上一篇:插入式涡街流量计
下一篇:JOKAB SAFETYJOK...