西门子数控驱动6FC5110-0DB03-0AA1

发布时间:2017-09-19

西门子数控驱动6FC5110-0DB03-0AA1

1) The rated output current Irated and the -load current IL are d on the duty cycle for low overload (LO).

2) The -load current IH is d on the duty cycle for high overload (HO).

3) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance and applies for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at rated power (d on Irated) – these current values are specified on the rating plate.

5) Max. motor cable length 25 m (82 ft) (shielded) for PM230 Power Modules with integrated line filter to maintain the limit values of EN 61800‑3 Category C2 (filter A) or C1 table 14 (filter B). With unshielded cables, Categories C2 and C1 are not achieved.

6) It is essential to plug on an operator panel or the blanking cover in order to achieve degree of protection IP54/IP55/UL Type 12. For more information, see Operator panels and blanking cover for PM230 Power Modules in section Supplementary system components.

 

上海昊征自动化科技有限公司

联系人:颜江

手机:

电话:

传真:

Q  Q:455499155

企业邮箱:xmz169@qq.com

上海昊征自动化科技有限公司在经营活动中精益求精,具备如下业务优势:

1、模块化控制器SIMATIC S7系列(S7-1200、S7-1500、S7-200、S7-200CN 、S7-200 SMART、S7-300、S7-400)、分布式I/O-SIMATIC ET 200。

2、西门子HMI操作设备及SCADA系统:TP177B面板、OP177B面板、MP177操作面板    、OP277面板、MP377操作面板、KP300PN面板、KTP400PN面板、KP400PN彩色     面板、KTP600PN面板、KTP600DP面板、KTP1000PN面板、KTP1000DP面板、      TP1500PN面板

3、西门子变频器。

4、西门子SITOP电源。

5、西门子CNC系统和CNC控制器-SINUMERIK数控系统(SINUMERIK840D、SINUMERIK802S/C、SINUMERIK802SL、SINUMERIK828D SINUMERIK801D 、SINUMERIK828 、SINUMERIK808 、SINUMERIK840)。

6、伺服变频器数控V20/V90/V80V60。

7、西门子3RW软启动。

8、西门子停产备件。

9、仪表和传感器等各系列产品。

上海昊征自动化科技有限公司凭借雄厚的技术实力及多年从事 SIEMENS 产品的销售经验,本着树立公司形象和对用户认真负责的精神开展业务,赢得了SIEMENS 公司与广大用户的好评及大力支持

【售后服务】:罚十,合同保证。

【产品质量】:质保保证,全新原装。

【产品价格】:价格优势,现货销售。

Line voltage 380 ... 480 V 3 AC

PM230 Power Modules, degree of protection IP55/UL Type 12

With integrated line filter class A

6SL3223-0DE22-2AG1

6SL3223-0DE23-0AG1

6SL3223-0DE24-0AG1

6SL3223-0DE25-5AG1

6SL3223-0DE27-5AG1

With integrated line filter class B

6SL3223-0DE22-2BG1

6SL3223-0DE23-0BG1

6SL3223-0DE24-0BG1

6SL3223-0DE25-5BG1

6SL3223-0DE27-5BG1

Output current

at 50 Hz 400 V 3 AC

 

 

 

 

 

 

  • Rated current Irated1)

A

5.9

7.7

10.2

13.2

18

  • Base-load currentIL1)

A

5.9

7.7

10.2

13.2

18

  • Base-load currentIH2)

A

4.1

5.9

7.7

10.2

13.2

  • Maximum currentImax

A

8.9

11.8

15.4

20.4

27

Rated power

 

 

 

 

 

 

  • Based on IL

kW

2.2

3

4

5.5

7.5

  • Based on IH

kW

1.5

2.2

3

4

5.5

Rated pulse frequency

kHz

4

4

4

4

4

Efficiency η

%

96

96

97

97

97

Power loss 3)

at rated current

kW

0.086

0.11

0.137

0.173

0.235

Cooling air requirement

m3/s (ft3/s)

0.007 (0.25)

0.007 (0.25)

0.009 (0.32)

0.009 (0.32)

0.009 (0.32)

Sound pressure level

LpA (1 m)

dB

61.9

61.9

62.8

62.8

62.8

24 V DC power supply

for Control Unit

A

1

1

1

1

1

Input current 4)

 

 

 

 

 

 

  • Rated current

A

6.1

8

11

14

19

  • Based on IH

A

4.2

6.1

8

11

14

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

2.5 ... 6

4 ... 6

4 ... 6

Motor connection

U2, V2, W2

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

2.5 ... 6

4 ... 6

4 ... 6

Motor cable length, max. 5)

 

 

 

 

 

 

  • Shielded

m (ft)

25 (82)

25 (82)

25 (82)

25 (82)

25 (82)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

Degree of protection6)

 

IP55/UL Type 12

IP55/UL Type 12

IP55/UL Type 12

IP55/UL Type 12

IP55/UL Type 12

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

154 (6.06)

154 (6.06)

180 (7.09)

180 (7.09)

180 (7.09)

  • Height

mm (in)

460 (18.11)

460 (18.11)

540 (21.26)

540 (21.26)

540 (21.26)

  • Depth

 

 

 

 

 

 

  • Without operator panel

mm (in)

249 (9.80)

249 (9.80)

249 (9.80)

249 (9.80)

249 (9.80)

  • With operator panel, max.

mm (in)

266 (10.47)

266 (10.47)

266 (10.47)

266 (10.47)

266 (10.47)

Frame size

 

FSA

FSA

FSB

FSB

FSB

Weight, approx.

kg (lb)

4.3 (9.48)

4.3 (9.48)

6.3 (13.9)

6.3 (13.9)

6.3 (13.9)


1) The rated output current Irated and the -load current IL are d on the duty cycle for low overload (LO).

2) The -load current IH is d on the duty cycle for high overload (HO).

3) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance and applies for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at rated power (d on Irated) – these current values are specified on the rating plate.

5) Max. motor cable length 25 m (82 ft) (shielded) for PM230 Power Modules with integrated line filter to maintain the limit values of EN 61800‑3 Category C2 (filter A) or C1 table 14 (filter B). With unshielded cables, Categories C2 and C1 are not achieved.

6) It is essential to plug on an operator panel or the blanking cover in order to achieve degree of protection IP54/IP55/UL Type 12. For more information, see Operator panels and blanking cover for PM230 Power Modules in section Supplementary system components.

 

Line voltage 380 ... 480 V 3 AC

PM230 Power Modules, degree of protection IP55/UL Type 12 1)

With integrated line filter class A

6SL3223-0DE31-1AG1

6SL3223-0DE31-5AG1

6SL3223-0DE31-8AG1

6SL3223-0DE32-2AA0

6SL3223-0DE33-0AA0

With integrated line filter class B

6SL3223-0DE31-1BG1

6SL3223-0DE31-5BG1

6SL3223-0DE31-8BA0

6SL3223-0DE32-2BA0

6SL3223-0DE33-0BA0

Output current

at 50 Hz 400 V 3 AC

 

 

 

 

 

 

 

  • Rated currentIrated2)

A

26

32

38

38

45

60

  • Base-load current IL 2)

A

26

32

38

38

45

60

  • Base-load current IH 3)

A

18

26

32

32

38

45

  • Maximum current Imax

A

39

52

64

48

57

67

Rated power

 

 

 

 

 

 

 

  • Based on IL

kW

11

15

18.5

18.5

22

30

  • Based on IH

kW

7.5

11

15

15

18.5

22

Rated pulse frequency

kHz

4

4

4

4

4

4

Efficiency η

%

97

97

98

97

97

97

Power loss 4)

at rated current

kW

0.299

0.365

0.435

0.478

0.569

0.784

Cooling air requirement

m3/s (ft3/s)

0.02 (0.7)

0.02 (0.7)

0.02 (0.7)

0.039 (1.4)

0.039 (1.4)

0.039 (1.4)

Sound pressure level

LpA (1 m)

dB

66.1

66.1

66.1

56

56

56

24 V DC power supply

for Control Unit

A

1

1

1

1

1

1

Input current 5)

 

 

 

 

 

 

 

  • Rated current

A

27

33

39

39

42

56

  • Based on IH

A

19

27

33

33

36

42

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

M6 screw studs

M6 screw studs

M6 screw studs

  • Conductor cross-section

mm2

6 ... 16

10 ... 16

10 ... 16

16 ... 35

16 ... 35

16 ... 35

Motor connection

U2, V2, W2

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

M6 screw studs

M6 screw studs

M6 screw studs

  • Conductor cross-section

mm2

6 ... 16

10 ... 16

10 ... 16

16 ... 35

16 ... 35

16 ... 35

Motor cable length, max. 6)

 

 

 

 

 

 

 

  • Shielded

m (ft)

25 (82)

25 (82)

25 (82)

25 (82)

25 (82)

25 (82)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

Degree of protection 7)

 

IP55/UL Type 12

IP55/UL Type 12

IP55/UL Type 12

IP55

IP55

IP55

Dimensions

 

 

 

 

 

 

 

  • Width

mm (in)

230 (9.06)

230 (9.06)

230 (9.06)

320 (12.60)

320 (12.60)

320 (12.60)

  • Height

mm (in)

620 (24.41)

620 (24.41)

620 (24.41)

640 (25.20)

640 (25.20)

640 (25.20)

  • Depth

 

 

 

 

 

 

 

  • Without operator panel

mm (in)

249 (9.80)

249 (9.80)

249 (9.80)

329 (12.95)

329 (12.95)

329 (12.95)

  • With operator panel, max.

mm (in)

266 (10.47)

266 (10.47)

266 (10.47)

346 (13.62)

346 (13.62)

346 (13.62)

Frame size

 

FSC

FSC

FSC

FSD

FSD

FSD

Weight, approx.

kg (lb)

9.5 (20.95)

9.5 (20.95)

9.5 (20.95)

31 (68.36)

31 (68.36)

31 (68.36)


1) UL Type 12 only for size FSC

2) The rated output current Irated and the -load current IL are d on the duty cycle for low overload (LO).

3) The -load current IH is d on the duty cycle for high overload (HO).

4) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

5) The input current depends on the motor load and line impedance and applies for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at rated power (d on Irated) – these current values are specified on the rating plate.

6) Max. motor cable length 25 m (82 ft) (shielded) for PM230 Power Modules with integrated line filter to maintain the limit values of EN 61800‑3 Category C2 (filter A) or C1 table 14 (filter B). With unshielded cables, Categories C2 and C1 are not achieved.

7) It is essential to plug on an operator panel or the blanking cover in order to achieve degree of protection IP54/IP55/UL Type 12. For more information, see Operator panels and blanking cover for PM230 Power Modules in section Supplementary system components.

 

Line voltage 380 ... 480 V 3 AC

PM230 Power Modules, degree of protection IP55

With integrated line filter class A

6SL3223-0DE33-7AA0

6SL3223-0DE34-5AA0

6SL3223-0DE35-5AA0

6SL3223-0DE37-5AA0

6SL3223-0DE38-8AA0

With integrated line filter class B

6SL3223-0DE33-7BA0

6SL3223-0DE34-5BA0

6SL3223-0DE35-5BA0

6SL3223-0DE37-5BA0

6SL3223-0DE38-8BA0

Output current

at 50 Hz 400 V 3 AC

 

 

 

 

 

 

  • Rated current Irated1)

A

75

90

110

145

178

  • Base-load current IL1)

A

75

90

110

145

178

  • Base-load current IH2)

A

60

75

90

110

145

  • Maximum current Imax

A

90

112

135

165

217

Rated power

 

 

 

 

 

 

  • Based on IL

kW

37

45

55

75

90

  • Based on IH

kW

30

37

45

55

75

Rated pulse frequency

kHz

4

4

4

4

4

Efficiency η

%

97

97

97

97

97

Power loss 3)

at rated current

kW

0.855

1.073

1.122

1.542

1.98

Cooling air requirement

m3/s (ft3/s)

0.039 (1.4)

0.039 (1.4)

0.117 (4.1)

0.117 (4.1)

0.117 (4.1)

Sound pressure level

LpA (1 m)

dB

56

56

61

61

61

24 V DC power supply

for Control Unit

A

1

1

1

1

1

Input current 4)

 

 

 

 

 

 

  • Rated current

A

70

84

102

135

166

  • Based on IH

A

56

70

84

102

135

Line supply connection

U1/L1, V1/L2, W1/L3

 

M6 screw studs

M6 screw studs

M8 screw studs

M8 screw studs

M8 screw studs

  • Conductor cross-section

mm2

25 ... 50

25 ... 50

35 ... 120

35 ... 120

35 ... 120

Motor connection

U2, V2, W2

 

M6 screw studs

M6 screw studs

M8 screw studs

M8 screw studs

M8 screw studs

  • Conductor cross-section

mm2

25 ... 50

25 ... 50

35 ... 120

35 ... 120

35 ... 120

Motor cable length, max. 5)

 

 

 

 

 

 

  • Shielded

m (ft)

25 (82)

25 (82)

25 (82)

25 (82)

25 (82)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

Degree of protection 6)

 

IP55

IP55

IP55

IP55

IP55

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

320 (12.60)

320 (12.60)

410 (16.14)

410 (16.14)

410 (16.14)

  • Height

mm (in)

751 (29.57)

751 (29.57)

915 (36.02)

915 (36.02)

915 (36.02)

  • Depth

 

 

 

 

 

 

  • Without operator panel

mm (in)

329 (12.95)

329 (12.95)

416 (16.38)

416 (16.38)

416 (16.38)

  • With operator panel, max.

mm (in)

346 (13.62)

346 (13.62)

433 (17.05)

433 (17.05)

433 (17.05)

Frame size

 

FSE

FSE

FSF

FSF

FSF

Weight, approx.

kg (lb)

37 (81.6) (with filter cl. A)
38 (83.8) (with filter cl. B)

37 (81.6) (with filter cl. A)
38 (83.8) (with filter cl. B)

70 (154)

70 (154)

70 (154)


1) The rated output current Irated and the -load current IL are d on the duty cycle for low overload (LO).

2) The -load current IH is d on the duty cycle for high overload (HO).

3) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance and applies for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at rated power (d on Irated) – these current values are specified on the rating plate.

5) Max. motor cable length 25 m (82 ft) (shielded) for PM230 Power Modules with integrated line filter to maintain the limit values of EN 61800‑3 Category C2 (filter A) or C1 table 14 (filter B). With unshielded cables, Categories C2 and C1 are not achieved.

6) It is essential to plug on an operator panel or the blanking cover in order to achieve degree of protection IP54/IP55. For more information, see Operator panels and blanking cover for PM230 Power Modules in section Supplementary system components.

 

PM230 Power Modules degree of protection IP20 Standard variant

Line voltage 380 ... 480 V 3 AC

PM230 Power Modules degree of protection IP20 Standard variant

Without integrated line filter

6SL3210-1NE11-3UG1

6SL3210-1NE11-7UG1

6SL3210-1NE12-2UG1

6SL3210-1NE13-1UG1

6SL3210-1NE14-1UG1

With integrated line filter class A

6SL3210-1NE11-3AG1

6SL3210-1NE11-7AG1

6SL3210-1NE12-2AG1

6SL3210-1NE13-1AG1

6SL3210-1NE14-1AG1

Output current

at 50 Hz 400 V 3 AC

 

 

 

 

 

 

  • Rated current Irated1)

A

1.3

1.7

2.2

3.1

4.1

  • Base-load currentIL1)

A

1.3

1.7

2.2

3.1

4.1

  • Base-load currentIH2)

A

0.9

1.3

1.7

2.2

3.1

  • Maximum currentImax

A

2

2.6

3.4

4.7

6.2

Rated power

 

 

 

 

 

 

  • Based on IL

kW

0.37

0.55

0.75

1.1

1.5

  • Based on IH

kW

0.25

0.37

0.55

0.75

1.1

Rated pulse frequency

kHz

4

4

4

4

4

Efficiency η

%

89

93

93

94

95

Power loss 3)

at rated current

kW

0.031

0.034

0.041

0.049

0.06

Cooling air requirement

m3/s (ft3/s)

0.002 (0.1)

0.002 (0.1)

0.005 (0.2)

0.005 (0.2)

0.005 (0.2)

Sound pressure level

LpA (1 m)

dB

<50

<50

<50

<50

<50

24 V DC power supply

for Control Unit

A

1

1

1

1

1

Input current 4)

 

 

 

 

 

 

  • Rated current

A

1.3

1.8

2.3

3.2

4.2

  • Based on IH

A

0.9

1.3

1.8

2.3

3.2

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

Motor connection

U2, V2, W2

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

  • Conductor cross-section

mm2

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

1 ... 2.5

Motor cable length, max. 5)

 

 

 

 

 

 

  • Shielded

m (ft)

25 (82)

25 (82)

25 (82)

25 (82)

25 (82)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

73 (2.87)

  • Height

mm (in)

196 (7.72)

196 (7.72)

196 (7.72)

196 (7.72)

196 (7.72)

  • Depth

 

 

 

 

 

 

  • Without operator panel

mm (in)

165 (6.50)

165 (6.50)

165 (6.50)

165 (6.50)

165 (6.50)

  • With operator panel, max.

mm (in)

245 (9.65)

245 (9.65)

245 (9.65)

245 (9.65)

245 (9.65)

Frame size

 

FSA

FSA

FSA

FSA

FSA

Weight, approx.

 

 

 

 

 

 

  • Without integrated line filter

kg (lb)

1.4 (3.09)

1.4 (3.09)

1.4 (3.09)

1.4 (3.09)

1.4 (3.09)

  • With integrated line filter

kg (lb)

1.6 (3.53)

1.6 (3.53)

1.6 (3.53)

1.6 (3.53)

1.6 (3.53)


1) The rated output current Irated and the -load current IL are d on the duty cycle for low overload (LO).

2) The -load current IH is d on the duty cycle for high overload (HO).

3) Typical values. You can find more information on the Internet at https://support.industry.siemens.com/cs/document/94059311

4) The input current depends on the motor load and line impedance and applies for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at rated power (d on Irated) – these current values are specified on the rating plate.

5) Max. motor cable length 25 m (82 ft) (shielded) for PM230 Power Modules with integrated line filter to maintain the limit values acc. to EN 61800‑3 Category C2. With unshielded cables, Category C2 is not achieved.

 

Line voltage 380 ... 480 V 3 AC

PM230 Power Modules degree of protection IP20 Standard variant

Without integrated line filter

6SL3210-1NE15-8UG1

6SL3210-1NE17-7UG1

6SL3210-1NE21-0UG1

6SL3210-1NE21-3UG1

6SL3210-1NE21-8UG1

With integrated line filter class A

6SL3210-1NE15-8AG1

6SL3210-1NE17-7AG1

6SL3210-1NE21-0AG1

6SL3210-1NE21-3AG1

6SL3210-1NE21-8AG1

Output current

at 50 Hz 400 V 3 AC

 

 

 

 

 

 

  • Rated current Irated1)

A

5.9

7.7

10.2

13.2

18

  • Base-load currentIL1)

A

5.9

7.7

10.2

13.2

18

  • Base-load currentIH2)

A

4.1

5.9

7.7

10.2

13.2

  • Maximum currentImax

A

8.9

11.8

15.4

20.4

27

Rated power

 

 

 

 

 

 

  • Based on IL

kW

2.2

3

4

5.5

7.5

  • Based on IH

kW

1.5

2.2

3

4

5.5

Rated pulse frequency

kHz

4

4

4

4

4

Efficiency η

%

96

96

97

97

97

Power loss 3)

at rated current

kW

0.078

0.102

0.13

0.165

0.224

Cooling air requirement

m3/s (ft3/s)

0.005 (0.2)

0.005 (0.2)

0.009 (0.3)

0.009 (0.3)

0.009 (0.3)

Sound pressure level

LpA (1 m)

dB

<50

<50

<62

<62

<62

24 V DC power supply

for Control Unit

A

1

1

1

1

1

Input current 4)

 

 

 

 

 

 

  • Rated current

A

6.1

8

11

14

19

  • Based on IH

A

4.2

6.1

8

11

14

Line supply connection

U1/L1, V1/L2, W1/L3

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

  • Conductor cross-section

mm2

1.5 ... 2.5

1.5 ... 2.5

1.5 ... 6

1.5 ... 6

1.5 ... 6

Motor connection

U2, V2, W2

 

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

Screw-type terminals, plug-in

  • Conductor cross-section

mm2

1.5 ... 2.5

1.5 ... 2.5

1.5 ... 6

1.5 ... 6

1.5 ... 6

Motor cable length, max. 5)

 

 

 

 

 

 

  • Shielded

m (ft)

25 (82)

25 (82)

25 (82)

25 (82)

25 (82)

  • Unshielded

m (ft)

100 (328)

100 (328)

100 (328)

100 (328)

100 (328)

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

73 (2.87)

73 (2.87)

100 (328.10)

100 (328.10)

100 (328.10)

  • Height

mm (in)

196 (7.72)

196 (7.72)

292 (11.50)

292 (11.50)

292 (11.50)

  • Depth

 

 

 

 

 

 

  • Without operator panel

mm (in)

165 (6.50)

165 (6.50)

165 (6.50)

165 (6.50)

165 (6.50)

  • With operator panel, max.

mm (in)

245 (9.65)

245 (9.65)

245 (9.65)

245 (9.65)

245 (9.65)

Frame size

 

FSA

FSA

FSB

FSB

FSB

Weight, approx.

 

 

 

 

 

 

  • Without integrated line filter

kg (lb)

1.4 (3.09)

1.4 (3.09)

2.8 (6.17)

2.8 (6.17)

2.8 (6.17)

  • With integrated line filter

kg (lb)

1.6 (3.53)

1.6 (3.53)

3 (6.61)

3 (6.61)

3 (6.61)

西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1西门子数控驱动6FC5110-0DB03-0AA1

上一篇:pe热收缩膜配方分析
下一篇:氟塑料磁力泵运行注意事项