The SINAMICS G120 frequency inverter is designed to provide precise and cost-effective speed/torque control of three-phase motors.

With different device versions ( sizes FSA to FSGX) in a power range from 0.37 kW to 250 kW (0.5 hp to 400 hp), it is suitable for a wide variety of drive solutions.

Example: SINAMICS G120, sizes FSA, FSB and FSC; each with Power Module, CU240E‑2 F Control Unit and Basic Operator Panel BOP-2

Example: SINAMICS G120, sizes FSD, FSE and FSF; each with Power Module, CU240E‑2 F Control Unit and Intelligent Operator Panel IOP

Example: SINAMICS G120, size FSGX; with Power Module, CU240E‑2 F Control Unit and Basic Operator Panel BOP-2

Operator-friendly design

SINAMICS G120 is a modular inverter system that essentially comprises two function units:

The Control Unit controls and monitors the Power Module and the connected motor using several different closed-loop control types that can be selected. It supports communication with a local or central controller and monitoring devices.

The Power Module supplies the motor in the power range 0.37 kW to 250 kW (0.5 hp to 400 hp). It features state-of-the-art IGBT technology with pulse-width-modulated motor voltage and selectable pulse frequency. Comprehensive protection functions provide a high degree of protection for the Power Module and the motor.

The Control Units can be combined with the following Power Modules:

Control Units

Power Modules degree of protection IP20

 

PM240‑2

PM240

PM250

CU230P‑2

✓ 

✓ 

✓ 

CU240E‑2

✓ 

✓ 

✓ 

CU250S‑2

✓ 

✓ 

✓ 



Safety Integrated

SINAMICS G120 standard inverters are available in different versions for safety-related applications. The PM240‑2 and PM250 Power Modules are already designed for Safety Integrated. PM240 Power Modules, size FSGX (i.e. 160 kW/250 hp and higher) are approved only for the Basic Safety functions (STO, SS1, and SBC). A drive can be combined with a Control Unit with safety functions (see overview) in order to create a Safety Integrated drive. The availability of Safety Integrated functions depends on the type of Control Unit.

Control Unit

Basic Safety functions

Extended Safety functions

 

STO

SS1

SBC 1)

SLS

SDI

SSM

CU230P‑2

CU240E‑2

✓ 

CU240E‑2 F

✓ 

✓ 

✓ 

✓ 

✓ 2)

CU250S‑2

✓ 

✓ 

✓ 

✓ 3)

✓ 3)

✓ 3)



1) The SBC function can be utilized only if a Safe Brake Relay is installed.

2) SSM possible only for CU240E‑2 DP‑F / CU240E‑2 PN‑F Control Units with PROFIsafe.

3) With license for Extended Safety functions.

Basic Safety functions (certified according to IEC 61508 SIL 2, and EN ISO 13849‑1 PL d and Category 3)

Extended Safety functions (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3)

Basic Safety and Extended Safety functions can be activated via PROFIsafe or by means of the safety inputs.

None of the safety functions require a motor encoder and they are thus cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.

The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SSM and SDI functions are only permissible for applications where the load can never accelerate when the inverter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.

Additional information is provided in chapter Highlights, section Safety Integrated.

Efficient Infeed Technology

The innovative Efficient Infeed Technology is employed in PM250 Power Modules. This technology allows the energy produced by motors operating in generator mode connected to standard inverters to be fed back into the supply system. For control cabinets, an additional temperature rise can be avoided and the amount of space required can be reduced due to the fact that components such as braking resistors, braking choppers and line reactors can be eliminated. Further, wiring and engineering costs are significantly reduced. At the same time, energy consumption can be reduced and ongoing operating costs noticeably reduced.

Additional information is provided in chapter Highlights, section Efficient Infeed Technology.

Innovative cooling concept and varnishing of electronic modules

The new cooling system and varnishing of the electronic modules significantly increases the service life or useful life of the device.

Energy efficiency

Integrated technologies help when optimizing the energy usage of the plant or system referred to the particular application:

Additional information is provided in chapter Highlights, section Energy efficiency.

优势

设计

Application-orientated design of SINAMICS G120

SINAMICS G120 standard inverters are modular inverters for standard drives. Selection of the SINAMICS G120 is reduced to two or three steps thanks to the modular system used.

Selecting the Control Unit

The optimum Control Unit is selected first, d on the number of I/Os and any additional functions required such as Safety Integrated or HVAC. The communication options are already integrated and do not have to be additionally ordered or plugged in. Three product series are available corresponding to the particular application.

CU230P‑2 Control Units

The CU230P‑2 Control Units have been specifically designed for pump, fan and compressor applications.
The CU230P‑2 is the Control Unit for the pump, fan and compressor inverters SINAMICS G120P and SINAMICS G120P Cabinet. Detailed information can be found in Catalog D 35.

Control Unit CU240E‑2

The CU240E‑2 Control Unit is suitable for a wide range of applications in general machine construction, such as conveyor belts, mixers and extruders.

CU250S‑2 Control Units

The CU250S‑2 Control Units are suitable for applications involving single drives with exacting speed control requirements such as extruders and centrifuges, and for positioning tasks such as conveyor belts, lifting/lowering devices, etc. They can also be used to implement multi-motor drives without DC coupling such as wire-drawing machines and simple material lines.

 

Deion

Fieldbus

Profile

Inputs
Outputs

Integrated safety technology

Fail-safe
digital inputs
digital outputs

Control Unit

 

 

 

 

 

 

Article No.

CU230P‑2 series - the specialist for pumps, fans, compressors, water, buildings

Technology functions (selection): Free function blocks (FFB), 4 × PID controller, cascade connection, hibernation mode, essential service mode, multi-zone control

CU230P‑2 HVAC

  • USS

  • Modbus RTU

  • BACnet MS/TP

  • FLN P1

6 DI
4 AI

3 DO
2 AO

6SL3243-0BB30-1HA3

CU230P‑2 DP

  • PROFIBUS DP

  • PROFIdrive

6SL3243-0BB30-1PA3

CU230P‑2 PN

  • PROFINET

  • PROFIdrive

  • PROFIenergy

6SL3243-0BB30-1FA0

  • EtherNet/IP

  • ODVA AC drive

  • SINAMICS profile

CU240E‑2 series – for standard applications in general machinery construction, such as conveyor belts, mixers and extruders – without encoder

Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake

CU240E‑2

  • USS

  • Modbus RTU

6 DI
2 AI

3 DO
2 AO

STO

1 F-DI
(opt. for each 2 DI)

6SL3244-0BB12-1BA1

CU240E‑2 DP

  • PROFIBUS DP

  • PROFIdrive

  • PROFIsafe

6SL3244-0BB12-1PA1

CU240E‑2 PN

  • PROFINET

  • PROFIdrive

  • PROFIsafe

  • PROFIenergy

6SL3244-0BB12-1FA0

  • EtherNet/IP

  • ODVA AC drive

  • SINAMICS profile

CU240E‑2 F

  • USS

  • Modbus RTU

STO, SS1, SLS, SDI

3 F-DI
(opt. for each 2 DI)

6SL3244-0BB13-1BA1

CU240E‑2 DP‑F

  • PROFIBUS DP

  • PROFIdrive

  • PROFIsafe

STO, SS1, SLS, SSM 1), SDI

6SL3244-0BB13-1PA1

CU240E‑2 PN‑F

  • PROFINET

  • PROFIdrive

  • PROFIsafe

  • PROFIenergy

6SL3244-0BB13-1FA0

  • EtherNet/IP

  • ODVA AC drive

  • SINAMICS profile

CU250S‑2 series – for complex applications such as extruders and centrifuges – with and without encoder (basic positioner (EPos) optional)

Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake

CU250S‑2

  • USS

  • Modbus RTU

11 DI
2 AI

3 DO
2 AO

4 DI/DO (DI can be used as high-speed inputs)

STO, SBC, SS1

3 F-DI
(opt. for each 2 DI)

1 F-DO
(opt. for each 2 DO)

6SL3246-0BA22-1BA0

CU250S‑2 DP

  • PROFIBUS DP

  • PROFIdrive

  • PROFIsafe

6SL3246-0BA22-1PA0

CU250S‑2 PN

  • PROFINET

  • PROFIdrive

  • PROFIsafe

  • PROFIenergy

6SL3246-0BA22-1FA0

  • EtherNet/IP

  • ODVA AC drive

  • SINAMICS profile

CU250S‑2 CAN

  • CANopen

6SL3246-0BA22-1CA0



1) SSM is possible only with PROFIsafe.

Optional memory card with firmware V4.7 SP6 for CU230P‑2, CU240E‑2 and CU250S‑2 Control Units

Deion

Suitable for

Article No.

SINAMICS SD card

512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6)

CU230P‑2
CU240E‑2
CU250S‑2

6SL3054-7TD00-2BA0



Optional memory cards with licenses for CU250S‑2 Control Units only

Deion

SINAMICS SD card
512 MB + licenses

SINAMICS SD card
512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6) + licenses

Licenses (without SD card)
for upgrading license 
of an existing SD card

 

Article No.

Article No.

Article No.

License Extended Functions 
Basic positioner (EPos)

6SL3054-4AG00-2AA0-Z

E01

6SL3054-7TD00-2BA0-Z

E01

6SL3074-7AA04-0AA0

License Extended Functions 
Safety (SLS, SSM, SDI)

6SL3054-4AG00-2AA0-Z

F01

6SL3054-7TD00-2BA0-Z

F01

6SL3074-0AA10-0AA0

Licenses Extended Functions 
Basic positioner (EPos) + Safety (SLS, SSM, SDI)

6SL3054-4AG00-2AA0-Z

E01+F01

6SL3054-7TD00-2BA0-Z

E01+F01



For additional information about firmware V4.7 SP6:

https://support.industry.siemens.com/cs/document/109482094

Optional memory cards with firmware V4.6 or V4.7 for existing installations when service is required

Deion

Suitable for

Article No.

SINAMICS SD card

512 MB + firmware V4.6 (Multicard V4.6)

CU230P‑2
CU240E‑2
CU250S‑2

6SL3054-7EG00-2BA0

SINAMICS SD card

512 MB + firmware V4.7 (Multicard V4.7)

CU230P‑2
CU240E‑2
CU250S‑2

6SL3054-7EH00-2BA0



For an overview and more information on all available firmware versions, see https://support.industry.siemens.com/cs/document/67364620

Selecting the Power Module

The optimum power unit can be quickly selected d on the required motor power, the supply voltage and the braking cycles to be expected. Power Modules in degree of protection IP20 are intended for installation in a control cabinet.

PM240‑2 and PM240 Power Modules – IP20 degree of protection

PM240‑2 Power Modules have an integrated braking chopper (four-quadrant applications) and are suitable for a large number of applications in general machinery construction. The same applies for PM240 Power Modules, but the PM240 Power Modules in size FSGX do not have an integrated braking chopper. A plug-in Braking Module is optionally available for this purpose.

PM250 Power Modules – degree of protection IP20

PM250 Power Modules are suitable for the same applications as the PM240‑2/PM240. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking resistor is not required).

The Power Modules can be combined with the following Control Units:

Control Units

Power Modules degree of protection IP20

 

PM240‑2/PM240

PM250

CU230P‑2

✓ 

✓ 

CU240E‑2

✓ 

✓ 

CU250S‑2

✓ 

✓ 



 

PM240, PM240‑2 and PM250 Power Modules

Rated power 1)

 

Rated output current Irated2)

PM240‑2 Power Modules 3)
Degree of protection IP20

All CUs pluggable

PM250
Power Module degree of protection IP20

All CUs pluggable

kW

hp

A

Article No.

Article No.

200 ... 240 V 1 AC/3 AC

0.55

0.75

3.2

6SL3210-1PB13-0❒L0

0.75

1

4.2

6SL321❒-1PB13-8❒L0

1.1

1.5

6

6SL3210-1PB15-5❒L0

1.5

2

7.4

6SL3210-1PB17-4❒L0

2.2

3

10.4

6SL321❒-1PB21-0❒L0

3

4

13.6

6SL3210-1PB21-4❒L0

4

5

17.5

6SL321❒-1PB21-8❒L0

200 ... 240 V 3 AC

5.5

7.5

22

6SL3210-1PC22-2❒L0

7.5

10

28

6SL3210-1PC22-8❒L0

11

15

42

6SL3210-1PC24-2UL0

15

20

54

6SL3210-1PC25-4UL0

18.5

25

68

6SL3210-1PC26-8UL0

22

30

80

6SL3210-1PC28-0UL0

30

40

104

6SL3210-1PC31-1UL0

37

50

130

6SL3210-1PC31-3UL0

45

60

154

6SL3210-1PC31-6UL0

55

75

178

6SL3210-1PC31-8UL0

380 ... 480 V 3 AC

0.37 4)

0.5

1.3

– 4)

0.55

0.75

1.7

6SL3210-1PE11-8❒L1

0.75

1

2.2

6SL3210-1PE12-3❒L1

1.1

1.5

3.1

6SL3210-1PE13-2❒L1

1.5

2

4.1

6SL3210-1PE14-3❒L1

2.2

3

5.9

6SL3210-1PE16-1❒L1

3

4

7.7

6SL321❒-1PE18-0❒L1

4

5

10.2

6SL3210-1PE21-1❒L0

5.5

7.5

13.2

6SL3210-1PE21-4❒L0

7.5

10

18

6SL321❒-1PE21-8❒L0

6SL3225-0BE25-5AA1

11

15

26/25

6SL3210-1PE22-7❒L0

6SL3225-0BE27-5AA1

15

20

32

6SL321❒-1PE23-3❒L0

6SL3225-0BE31-1AA1

18.5

25

38

6SL3210-1PE23-8❒L0

6SL3225-0BE31-5❒A0

22

30

45

6SL3210-1PE24-5❒L0

6SL3225-0BE31-8❒A0

30

40

60

6SL3210-1PE26-0❒L0

6SL3225-0BE32-2❒A0

37

50

75

6SL3210-1PE27-5❒L0

6SL3225-0BE33-0❒A0

45

60

90

6SL3210-1PE28-8❒L0

6SL3225-0BE33-7❒A0

55

75

110

6SL3210-1PE31-1❒L0

6SL3225-0BE34-5❒A0

75

100

145

6SL3210-1PE31-5❒L0

6SL3225-0BE35-5❒A0

90

125

178

6SL3210-1PE31-8❒L0

6SL3225-0BE37-5❒A0

110

150

205

6SL3210-1PE32-1❒L0

132

200

250

6SL3210-1PE32-5❒L0

160 3)

250

302

6SL3224-0XE41-3UA0

200 3)

300

370

6SL3224-0XE41-6UA0

250 3)

400

477

6SL3224-0XE42-0UA0

500 ... 690 V 3 AC

11

10

14

6SL3210-1PH21-4❒L0

15

15

19

6SL3210-1PH22-0❒L0

18.5

20

23

6SL3210-1PH22-3❒L0

22

25

27

6SL3210-1PH22-7❒L0

30

30

35

6SL3210-1PH23-5❒L0

37

40

42

6SL3210-1PH24-2❒L0

45

50

52

6SL3210-1PH25-2❒L0

55

60

62

6SL3210-1PH26-2❒L0

75

75

80

6SL3210-1PH28-0❒L0

90

100

100

6SL3210-1PH31-0❒L0

110

100

115

6SL3210-1PH31-2❒L0

132

125

142

6SL3210-1PH31-4❒L0

Heat sink variant



             ↑


Standard



             0


Push Through



             1


Integrated line filter



                               ↑

                               ↑

Without

(for IT systems)


                               U

                               U

Class A

(for TN systems)


                               A

                               A

Class B

(for TN systems)


Integrated line filter not available, as external option only



1) Rated power d on the rated output current Irated. The rated output current Irated is d on the duty cycle for low overload (LO). Low overload (LO) generally applies for applications with low dynamic response (continuous operation), quadratic torque characteristic with low break loose torque and low speed accuracy. Examples: Centrifugal pumps, radial/axial fans, rotary piston fans, radial compressors, vacuum pumps, chain conveyors, agitators. High Overload (HO) generally applies for applications with increased dynamic response (cyclic operation) and constant torque characteristics with high break loose torque. Examples: Gear pumps, eccentric worm pumps, mills, mixers, crushers, lifting/lowering gear, centrifuges.

2) The rated output current Irated is d on the duty cycle for low overload (LO). These current values are applicable for 200 V, 400 V or 690 V.

3) 160 kW ... 250 kW, PM240 Power Modules ( size FSGX).

4) The PM240‑2 Power Module with Article No. 6SL3210-1PE11-8. L1 corresponds to 0.37 kW (0.5 hp) with duty cycle HO.

Data d on a duty cycle with low overload (LO). Data d on duty cycle with high overload (HO), see section Power Modules.

Selecting optional system components

Intelligent Operator Panel IOP

Graphic display with bar-type diagrams, e.g. for status values such as pressure or flowrate.

User-friendly commissioning, diagnostics and local operator control using a large plain text display, clear menu navigation and application wizards.

Intelligent Operator Panel IOP Handheld

A handheld version of the IOP can be ordered for mobile use. In addition to the IOP, this includes a housing with rechargeable batteries, charging unit and RS232 connecting cable.

Basic Operator Panel BOP-2

Menu navigation and 2-line display permit fast and user-friendly commissioning of the inverter.

Simple basic commissioning by simultaneously displaying parameter and parameter value, as well as the option of filtering parameters.

Door mounting kit for IOP/BOP‑2

Using the optionally available door mounting kit, the IOP/BOP‑2 can be mounted in a control cabinet door with just a few manual operations (IP54/UL Type 12 degree of protection is achieved).

Push-through mounting for Push Through variants of the PM240‑2 Power Modules

It is advisable to use an optionally available mounting to install the push-through unit in a control cabinet. This mounting includes the necessary seals and to ensure compliance with degree of protection IP54. If the Power Module is installed without use of the optional mounting , the user is responsible for ensuring that the requisite degree of protection is provided. The kit contains all the necessary nuts and seals.

Memory card

The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced, the drive system is immediately ready for use again. The memory card can also be used to upgrade the firmware of the Control Unit.

Brake Relay

The Brake Relay allows the Power Module to be connected to an electromechanical motor brake. This allows the motor brake to be controlled directly from the Control Unit.

Safe Brake Relay

The Safe Brake Relay allows the Power Module to be safely connected to an electromechanical motor brake, allowing the brake to be directly and safely controlled from the CU250S‑2 Control Unit in accordance with IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3.

PC inverter connection kit 2

For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool or SINAMICS Startdrive) has been installed.

Shield connection kit for Power Modules

The shield connection kit makes it easier to connect the shields of supply and control cables, provides mechanical strain relief and thus ensures optimum EMC performance. The shield connection kit is included in the scope of delivery of PM240‑2 Power Modules, sizes FSA to FSF.

Shield connection kit for Control Units

The shield connection kit offers optimum shield connection and strain relief for all signal and communication cables. It includes a matching shield bonding plate and all of the necessary connecting and retaining elements for mounting.

Deion

Article No.

Intelligent Operator Panel IOP


  • German, English, French, Italian, Spanish, Portuguese, Dutch, Swedish, Russian, Czech, Polish, Turkish, Finnish

6SL3255-0AA00-4JA1

  • Chinese (simplified), English, German

6SL3255-0AA00-4JC1

Operator Panel IOP Handheld

6SL3255-0AA00-4HA0

Operator Panel BOP‑2

6SL3255-0AA00-4CA1

Door mounting kit

for IOP/BOP‑2

6SL3256-0AP00-0JA0

Push-through mounting


  • For PM240‑2 Power Modules degree of protection IP20, Push Through variants


  • Frame size FSA

6SL3260-6AA00-0DA0

  • Frame size FSB

6SL3260-6AB00-0DA0

  • Frame size FSC

6SL3260-6AC00-0DA0

Memory card


  • SINAMICS SD card 1)
    512 MB

6SL3054-4AG00-2AA0

Brake Relay

6SL3252-0BB00-0AA0

Safe Brake Relay

6SL3252-0BB01-0AA0

PC inverter connection kit 2

6SL3255-0AA00-2CA0

Shield connection kits


  • For PM240‑2 Power Modules


  • Frame sizes FSA to FSF

Supplied with the Power Modules, available as a spare part

  • For PM250 Power Modules


  • Frame size FSC

6SL3262-1AC00-0DA0

  • Frame sizes FSD and FSE

6SL3262-1AD00-0DA0

  • Frame size FSF

6SL3262-1AF00-0DA0

  • For Control Units


  • For CU230P‑2 HVAC and CU230P‑2 DP

6SL3264-1EA00-0FA0

  • For CU240E‑2

6SL3264-1EA00-0HA0

  • For CU230P‑2 PN, CU240E‑2 PN and CU240E‑2 PN‑F

6SL3264-1EA00-0HB0

  • For CU250S‑2

6SL3264-1EA00-0LA0

STARTER commissioning tool 2)

on DVD‑ROM

6SL3072-0AA00-0AG0

SINAMICS Startdrive commissioning tool 3)

on DVD‑ROM

6SL3072-4DA02-0XG0



1) Approved only for CU230P‑2 HVAC and CU230P‑2 DP Control Units with firmware version V4.6 and higher.

2) The STARTER commissioning tool is also available on the Internet at http://www.siemens.com/starter

3) The SINAMICS Startdrive commissioning tool is also available on Internet at https://support.industry.siemens.com/cs/document/68034568

Line-side power components

The following line-side power components are available for SINAMICS G120 standard inverters:

Line filters

With one of the additional line filters, the Power Module attains a higher radio interference class.

Line reactors
(only for PM240‑2 Power Modules, sizes FSA to FSC, and PM240 FSGX)

Line reactors smooth the current drawn by the inverter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC- capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the inverter.

Note:

A DC reactor is integrated in the PM240‑2 Power Modules FSD to FSF and therefore no line reactor is required.

Recommended line-side power components

Furthermore, this is a recommendation for additional line-side components, such as fuses and circuit breakers (line-side components must be dimensioned in accordance with IEC standards).

Additional information about the line-side power components can be found in Catalogs LV 10, IC 10 and IC 10 AO as well as the Industry Mall.

DC components

The following DC components are available for the SINAMICS G120 standard inverters:

Braking resistors
(for PM240 and PM240‑2 Power Modules only)

Excess energy in the DC is dissipated in the braking resistor. The braking resistors are designed for use with PM240 and PM240‑2 Power Modules. They are equipped with an integrated braking chopper (electronic switch). There is an optional plug-in Braking Module for size FSGX.

Braking Module
(for PM240 Power Modules, size FSGX only)

A Braking Module and the matching external braking resistor are required to bring drives with a PM240 Power Module, size FSGX, to a controlled standstill in the event of a power failure (e.g. emergency retraction or EMERGENCY STOP Category 1) or to limit the DC voltage during a short period of generator operation. The Braking Module houses the power electronics and the associated control circuit.

Load-side power components

The following load-side power components are available for the SINAMICS G120 standard inverters. This means that during operation with output reactors or sine-wave filters, longer, shielded motor cables are possible and the motor service life can be extended:

Output reactors
(not for PM240-2 Power Modules, sizes FSD to FSF, as these have an integrated DC reactor)

Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.

Sine-wave filters
(not for PM240‑2 Power Modules)

Sine-wave filters limit the rate of voltage rise (dv/dt) and the peak voltages on the motor winding. Similar to an output reactor, they enable the connection of longer motor cables.

Additional options

Further selected supplementary products are available from Siemens Partners. 
Please select “Drive Options” as the technology in the "Solution Partner Finder” :
http://www.siemens.com/automation/partnerfinder

Spare parts

Spare parts kit for Control Units

The spare parts kit contains small parts for all variants of the following SINAMICS G120 Control Units:

Shield connection kits for PM240‑2 Power Modules

A shield connection kit is supplied as standard with PM240‑2 Power Modules in sizes FSA to FSF. This shield connection kit is also available as a spare part.

Replacement door for PM240 Power Modules, size FSGX

A complete replacement door can be ordered for the PM240 Power Module, size FSGX.

Terminal cover kits for sizes FSD to FSF

The terminal cover kit includes a replacement cover for the connecting terminals. Terminal cover kits which are suitable for the PM240‑2 and PM250 Power Modules are available.

Replacement connectors for PM240‑2 Power Modules

A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the size of the PM240‑2 Power Module.

Fan units for PM240‑2 Power Modules

The fans of PM240‑2 Power Modules are designed for extra long service life. For special requirements, replacement fans are available that can be exchanged quickly and easily.

Replacement fans for PM240 and PM250 Power Modules

The fans of PM240 and PM250 Power Modules are designed for extra long service life. Replacement fans can be ordered for special applications.

组态

The following electronic configuring aids and engineering tools are available for the SINAMICS G120 standard inverters:

Drive Technology Configurator (DT Configurator) within the CA 01

The interactive catalog CA 01 – the offline Industry Mall of Siemens on DVD‑ROM – contains over 100 000 products with approximately 5 million possible drive system product variants. The Drive Technology Configurator (DT Configurator) has been developed to facilitate selection of the correct motor and/or inverter from the wide spectrum of drives. It is integrated in Catalog CA 01 as an add-on on DVD‑ROM.

Online DT Configurator

In addition, the DT Configurator can be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Industry Mall at the following address: 
http://www.siemens.com/dt-configurator

SIZER for Siemens Drives engineering tool

The SIZER for Siemens Drives engineering tool makes it easy to engineer the SINAMICS drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER for Siemens Drives is designed to support configuring of the entire drive system.

You can find further information on the SIZER for Siemens Drives engineering tool in the chapter Engineering tools.

The SIZER for Siemens Drives engineering tool is available free on the Internet at 
http://www.siemens.com/sizer

STARTER commissioning tool

The STARTER commissioning tool allows menu-ed commissioning, optimization and diagnostics. Apart from the SINAMICS drives, STARTER is also suitable for MICROMASTER 4 devices.

You can find further information about the STARTER commissioning tool in the chapter Engineering tools.

Additional information about the STARTER commissioning tool is available on the Internet at 
http://www.siemens.com/starter

SINAMICS Startdrive commissioning tool

SINAMICS Startdrive is a tool for configuring, commissioning, and diagnosing the SINAMICS family of drives and is integrated into the TIA Portal. SINAMICS Startdrive can be used to implement drive tasks with the SINAMICS G110M, SINAMICS G120, SINAMICS G120C, SINAMICS G120D and SINAMICS G120P inverter series. The commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives.

You can find further information on the SINAMICS Startdrive commissioning tool in the chapter Engineering tools.

The SINAMICS Startdrive commissioning tool is available free on the Internet at 
http://www.siemens.com/startdrive

Drive ES engineering system

Drive ES is the engineering system that can be used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. Two software packages are available for SINAMICS – Drive ES Basic and Drive ES PCS.

You can find further information about the Drive ES engineering system in the chapter Engineering tools.

Additional information about the Drive ES engineering system is available on the Internet at 
http://www.siemens.com/drive-es



上一篇: TOP越剪钳TR-25A武汉...
下一篇:阀的连接电缆NEBV-Z4WA2...