The SINAMICS G120 frequency inverter is designed to provide precise and cost-effective speed/torque control of three-phase motors.
With different device versions (
Example: SINAMICS G120,
Example: SINAMICS G120,
Example: SINAMICS G120,
SINAMICS G120 is a modular inverter system that essentially comprises two function units:
Control Unit (CU)
Power Module (PM)
The Control Unit controls and monitors the Power Module and the connected motor using several different closed-loop control types that can be selected. It supports communication with a local or central controller and monitoring devices.
The Power Module supplies the motor in the power range 0.37 kW to 250 kW (0.5 hp to 400 hp). It features state-of-the-art IGBT technology with pulse-width-modulated motor voltage and selectable pulse frequency. Comprehensive protection functions provide a high degree of protection for the Power Module and the motor.
The Control Units can be combined with the following Power Modules:
Control Units | Power Modules degree of protection IP20 | ||
---|---|---|---|
| PM240‑2 | PM240 | PM250 |
CU230P‑2 | ✓ | ✓ | ✓ |
CU240E‑2 | ✓ | ✓ | ✓ |
CU250S‑2 | ✓ | ✓ | ✓ |
SINAMICS G120 standard inverters are available in different versions for safety-related applications. The PM240‑2 and PM250 Power Modules are already designed for Safety Integrated. PM240 Power Modules,
Control Unit | Basic Safety functions | Extended Safety functions | ||||
---|---|---|---|---|---|---|
| STO | SS1 | SBC 1) | SLS | SDI | SSM |
CU230P‑2 | – | – | – | – | – | – |
CU240E‑2 | ✓ | – | – | – | – | – |
CU240E‑2 F | ✓ | ✓ | – | ✓ | ✓ | ✓ 2) |
CU250S‑2 | ✓ | ✓ | ✓ | ✓ 3) | ✓ 3) | ✓ 3) |
1) The SBC function can be utilized only if a Safe Brake Relay is installed.
2) SSM possible only for CU240E‑2 DP‑F / CU240E‑2 PN‑F Control Units with PROFIsafe.
3) With license for Extended Safety functions.
Basic Safety functions (certified according to IEC 61508 SIL 2, and EN ISO 13849‑1 PL d and Category 3)
Safe Torque Off (STO)
to protect against active movement of the drive
The PM240‑2 Power Modules,
Safe Stop 1 (SS1)
for continuous monitoring of a safe braking ramp
Safe Brake Control (SBC) is used to safely control a holding
brake. When enabled, SBC is always activated at the same time as STO. The Safe Brake Relay is used for SBC.
Extended Safety functions (certified according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3)
Safely Limited Speed (SLS)
for protection against dangerous movements on exceeding a speed limit
Safe Direction (SDI)
This function ensures that the drive can only rotate in the selected direction.
Safe Speed Monitoring (SSM)
This function signals if a drive operates below a specific speed/feed velocity.
Basic Safety and Extended Safety functions can be activated via PROFIsafe or by means of the safety inputs.
None of the safety functions require a motor encoder and they are thus cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SSM and SDI functions are only permissible for applications where the load can never accelerate when the inverter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.
Additional information is provided in chapter Highlights, section Safety Integrated.
The innovative Efficient Infeed Technology is employed in PM250 Power Modules. This technology allows the energy produced by motors operating in generator mode connected to standard inverters to be fed back into the supply system. For control cabinets, an additional temperature rise can be avoided and the amount of space required can be reduced due to the fact that components such as braking resistors, braking choppers and line reactors can be eliminated. Further, wiring and engineering costs are significantly reduced. At the same time, energy consumption can be reduced and ongoing operating costs noticeably reduced.
Additional information is provided in chapter Highlights, section Efficient Infeed Technology.
The new cooling system and varnishing of the electronic modules significantly increases the service life or useful life of the device.
Disposal of all heat losses via an external heat sink
Consequential convection cooling of the Control Unit, electronic modules are not located in the air duct
All cooling air from the fan is directed through the heat sink
Integrated technologies help when optimizing the energy usage of the plant or system referred to the particular application:
Energy-efficient vector control with or without sensors
Automatic flux reduction with U/f ECO mode
Integrated energy saving computer
Additional information is provided in chapter Highlights, section Energy efficiency.
Modularity ensures flexibility for a drive concept that is fit for the future
Control Unit can be hot-swapped
Pluggable terminals
The modules can be easily replaced, which makes the system extremely service friendly
The integrated safety functions significantly reduce the costs when integrating drives into safety-oriented machines or systems
Communications-capable via PROFINET or PROFIBUS with PROFIdrive Profile 4.0
Plant-wide engineering
Easy to handle
The innovative circuit design (bidirectional input rectifier with "pared-down" DC
Integrated USB interface for simplified, local commissioning and diagnostics
Application-specific functions for pumps, fans and compressors
Integrated are, e.g.:
4 freely-programmable PID controllers
Application-specific wizards
Pt1000/LG-Ni1000 temperature sensor interface
230 V AC relay
3 freely-programmable digital time switches
With CU250S‑2 Control Units: Integrated positioning functionality (basic positioner EPos) supports process-related implementation of positioning tasks with a high dynamic response. Positioning can be implemented with an incremental and/or absolute encoder (SSI)
With CU250S‑2 Control Units: Encoder interfaces DRIVE‑CLiQ, HTL/TTL/SSI (SUB‑D) and resolver/HTL (terminal)
With CU250S‑2 Control Units: Vector control with or without sensors
Integrated control functionality by using BICO technology
An innovative cooling concept and coated electronic modules increase robustness and service life
External heat sink
Electronic components are not located in air duct
Control Unit that is completely cooled by convection
Additional coating of the most important components
Simple unit replacement and quick copying of parameters using an optional Operator Panel or an optional memory card
Quiet motor operation as a result of the high pulse frequency
Compact, space-saving design
Software parameters for simple adaptation to 50 Hz or 60 Hz motors (IEC or NEMA motors)
2/3-wire control for static/pulsed signals for universal control via digital inputs
Fast engineering and commissioning by using standard engineering tools such as SIZER for Siemens Drives, STARTER, SINAMICS Startdrive, and Drive ES – STARTER is integrated into STEP 7 using Drive ES Basic, with all of the benefits of central data management and totally integrated communication
Certified worldwide for compliance with CE, UL, cUL, C-Tick (RCM) and Safety Integrated according to IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3
The PM240‑2 Power Modules,
SINAMICS G120 standard inverters are modular inverters for standard drives. Selection of the SINAMICS G120 is reduced to two or three steps thanks to the modular system used.
The optimum Control Unit is selected first,
CU230P‑2 Control Units
The CU230P‑2 Control Units have been specifically designed for pump, fan and compressor applications.
The CU230P‑2 is the Control Unit for the pump, fan and compressor inverters SINAMICS G120P and SINAMICS G120P Cabinet. Detailed information can be found in Catalog D 35.
Control Unit CU240E‑2
The CU240E‑2 Control Unit is suitable for a wide range of applications in general machine construction, such as conveyor belts, mixers and extruders.
CU250S‑2 Control Units
The CU250S‑2 Control Units are suitable for applications involving single drives with exacting speed control requirements such as extruders and centrifuges, and for positioning tasks such as conveyor belts, lifting/lowering devices, etc. They can also be used to implement multi-motor drives without DC coupling such as wire-drawing machines and simple material lines.
De | Fieldbus | Profile | Inputs | Integrated safety technology | Fail-safe | Control Unit |
---|---|---|---|---|---|---|
|
|
|
|
|
| Article No. |
CU230P‑2 series - the specialist for pumps, fans, compressors, water, buildings Technology functions (selection): Free function blocks (FFB), 4 × PID controller, cascade connection, hibernation mode, essential service mode, multi-zone control | ||||||
CU230P‑2 HVAC |
| – | 6 DI 3 DO | – | – | 6SL3243-0BB30-1HA3 |
CU230P‑2 DP |
|
| 6SL3243-0BB30-1PA3 | |||
CU230P‑2 PN |
|
| 6SL3243-0BB30-1FA0 | |||
| – | |||||
CU240E‑2 series – for standard applications in general machinery construction, such as conveyor belts, mixers and extruders – without encoder Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake | ||||||
CU240E‑2 |
| – | 6 DI 3 DO | STO | 1 F-DI | 6SL3244-0BB12-1BA1 |
CU240E‑2 DP |
|
| 6SL3244-0BB12-1PA1 | |||
CU240E‑2 PN |
|
| 6SL3244-0BB12-1FA0 | |||
| – | |||||
CU240E‑2 F |
| – | STO, SS1, SLS, SDI | 3 F-DI | 6SL3244-0BB13-1BA1 | |
CU240E‑2 DP‑F |
|
| STO, SS1, SLS, SSM 1), SDI | 6SL3244-0BB13-1PA1 | ||
CU240E‑2 PN‑F |
|
| 6SL3244-0BB13-1FA0 | |||
| – | |||||
CU250S‑2 series – for complex applications such as extruders and centrifuges – with and without encoder (basic positioner (EPos) optional) Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake | ||||||
CU250S‑2 |
| – | 11 DI 3 DO 4 DI/DO (DI can be used as high-speed inputs) | STO, SBC, SS1 | 3 F-DI 1 F-DO | 6SL3246-0BA22-1BA0 |
CU250S‑2 DP |
|
| 6SL3246-0BA22-1PA0 | |||
CU250S‑2 PN |
|
| 6SL3246-0BA22-1FA0 | |||
| – | |||||
CU250S‑2 CAN |
| – | 6SL3246-0BA22-1CA0 |
1) SSM is possible only with PROFIsafe.
De | Suitable for | Article No. |
---|---|---|
SINAMICS SD card 512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6) | CU230P‑2 | 6SL3054-7TD00-2BA0 |
De | SINAMICS SD card | SINAMICS SD card | Licenses (without SD card) |
---|---|---|---|
| Article No. | Article No. | Article No. |
License Extended Functions | 6SL3054-4AG00-2AA0-Z E01 | 6SL3054-7TD00-2BA0-Z E01 | 6SL3074-7AA04-0AA0 |
License Extended Functions | 6SL3054-4AG00-2AA0-Z F01 | 6SL3054-7TD00-2BA0-Z F01 | 6SL3074-0AA10-0AA0 |
Licenses Extended Functions | 6SL3054-4AG00-2AA0-Z E01+F01 | 6SL3054-7TD00-2BA0-Z E01+F01 | – |
For additional information about firmware V4.7 SP6:
https://support.industry.siemens.com/cs/document/109482094
De | Suitable for | Article No. |
---|---|---|
SINAMICS SD card 512 MB + firmware V4.6 (Multicard V4.6) | CU230P‑2 | 6SL3054-7EG00-2BA0 |
SINAMICS SD card 512 MB + firmware V4.7 (Multicard V4.7) | CU230P‑2 | 6SL3054-7EH00-2BA0 |
For an overview and more information on all available firmware versions, see https://support.industry.siemens.com/cs/document/67364620
The optimum power unit can be quickly selected
PM240‑2 and PM240 Power Modules – IP20 degree of protection
PM240‑2 Power Modules have an integrated braking chopper (four-quadrant applications) and are suitable for a large number of applications in general machinery construction. The same applies for PM240 Power Modules, but the PM240 Power Modules in
PM250 Power Modules – degree of protection IP20
PM250 Power Modules are suitable for the same applications as the PM240‑2/PM240. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking resistor is not required).
The Power Modules can be combined with the following Control Units:
Control Units | Power Modules degree of protection IP20 | |
---|---|---|
| PM240‑2/PM240 | PM250 |
CU230P‑2 | ✓ | ✓ |
CU240E‑2 | ✓ | ✓ |
CU250S‑2 | ✓ | ✓ |
PM240, PM240‑2 and PM250 Power Modules
Rated power 1) |
| Rated output current Irated2) | PM240‑2 Power Modules 3) All CUs pluggable | PM250 All CUs pluggable |
---|---|---|---|---|
kW | hp | A | Article No. | Article No. |
200 ... 240 V 1 AC/3 AC | ||||
0.55 | 0.75 | 3.2 | 6SL3210-1PB13-0❒L0 | – |
0.75 | 1 | 4.2 | 6SL321❒-1PB13-8❒L0 | – |
1.1 | 1.5 | 6 | 6SL3210-1PB15-5❒L0 | – |
1.5 | 2 | 7.4 | 6SL3210-1PB17-4❒L0 | – |
2.2 | 3 | 10.4 | 6SL321❒-1PB21-0❒L0 | – |
3 | 4 | 13.6 | 6SL3210-1PB21-4❒L0 | – |
4 | 5 | 17.5 | 6SL321❒-1PB21-8❒L0 | – |
200 ... 240 V 3 AC | ||||
5.5 | 7.5 | 22 | 6SL3210-1PC22-2❒L0 | – |
7.5 | 10 | 28 | 6SL3210-1PC22-8❒L0 | – |
11 | 15 | 42 | 6SL3210-1PC24-2UL0 | – |
15 | 20 | 54 | 6SL3210-1PC25-4UL0 | – |
18.5 | 25 | 68 | 6SL3210-1PC26-8UL0 | – |
22 | 30 | 80 | 6SL3210-1PC28-0UL0 | – |
30 | 40 | 104 | 6SL3210-1PC31-1UL0 | – |
37 | 50 | 130 | 6SL3210-1PC31-3UL0 | – |
45 | 60 | 154 | 6SL3210-1PC31-6UL0 | – |
55 | 75 | 178 | 6SL3210-1PC31-8UL0 | – |
380 ... 480 V 3 AC | ||||
0.37 4) | 0.5 | 1.3 | – 4) | – |
0.55 | 0.75 | 1.7 | 6SL3210-1PE11-8❒L1 | – |
0.75 | 1 | 2.2 | 6SL3210-1PE12-3❒L1 | – |
1.1 | 1.5 | 3.1 | 6SL3210-1PE13-2❒L1 | – |
1.5 | 2 | 4.1 | 6SL3210-1PE14-3❒L1 | – |
2.2 | 3 | 5.9 | 6SL3210-1PE16-1❒L1 | – |
3 | 4 | 7.7 | 6SL321❒-1PE18-0❒L1 | – |
4 | 5 | 10.2 | 6SL3210-1PE21-1❒L0 | – |
5.5 | 7.5 | 13.2 | 6SL3210-1PE21-4❒L0 | – |
7.5 | 10 | 18 | 6SL321❒-1PE21-8❒L0 | 6SL3225-0BE25-5AA1 |
11 | 15 | 26/25 | 6SL3210-1PE22-7❒L0 | 6SL3225-0BE27-5AA1 |
15 | 20 | 32 | 6SL321❒-1PE23-3❒L0 | 6SL3225-0BE31-1AA1 |
18.5 | 25 | 38 | 6SL3210-1PE23-8❒L0 | 6SL3225-0BE31-5❒A0 |
22 | 30 | 45 | 6SL3210-1PE24-5❒L0 | 6SL3225-0BE31-8❒A0 |
30 | 40 | 60 | 6SL3210-1PE26-0❒L0 | 6SL3225-0BE32-2❒A0 |
37 | 50 | 75 | 6SL3210-1PE27-5❒L0 | 6SL3225-0BE33-0❒A0 |
45 | 60 | 90 | 6SL3210-1PE28-8❒L0 | 6SL3225-0BE33-7❒A0 |
55 | 75 | 110 | 6SL3210-1PE31-1❒L0 | 6SL3225-0BE34-5❒A0 |
75 | 100 | 145 | 6SL3210-1PE31-5❒L0 | 6SL3225-0BE35-5❒A0 |
90 | 125 | 178 | 6SL3210-1PE31-8❒L0 | 6SL3225-0BE37-5❒A0 |
110 | 150 | 205 | 6SL3210-1PE32-1❒L0 | – |
132 | 200 | 250 | 6SL3210-1PE32-5❒L0 | – |
160 3) | 250 | 302 | 6SL3224-0XE41-3UA0 | – |
200 3) | 300 | 370 | 6SL3224-0XE41-6UA0 | – |
250 3) | 400 | 477 | 6SL3224-0XE42-0UA0 | – |
500 ... 690 V 3 AC | ||||
11 | 10 | 14 | 6SL3210-1PH21-4❒L0 | – |
15 | 15 | 19 | 6SL3210-1PH22-0❒L0 | – |
18.5 | 20 | 23 | 6SL3210-1PH22-3❒L0 | – |
22 | 25 | 27 | 6SL3210-1PH22-7❒L0 | – |
30 | 30 | 35 | 6SL3210-1PH23-5❒L0 | – |
37 | 40 | 42 | 6SL3210-1PH24-2❒L0 | – |
45 | 50 | 52 | 6SL3210-1PH25-2❒L0 | – |
55 | 60 | 62 | 6SL3210-1PH26-2❒L0 | – |
75 | 75 | 80 | 6SL3210-1PH28-0❒L0 | – |
90 | 100 | 100 | 6SL3210-1PH31-0❒L0 | – |
110 | 100 | 115 | 6SL3210-1PH31-2❒L0 | – |
132 | 125 | 142 | 6SL3210-1PH31-4❒L0 | – |
Heat sink variant | ↑ | |||
Standard | 0 | |||
Push Through | 1 | |||
Integrated line filter | ↑ | ↑ | ||
Without | (for IT systems) | U | U | |
Class A | (for TN systems) | A | A | |
Class B | (for TN systems) | – | Integrated line filter not available, as external option only |
1) Rated power
2) The rated output current Irated is
3) 160 kW ... 250 kW, PM240 Power Modules (
4) The PM240‑2 Power Module with Article No. 6SL3210-1PE11-8. L1 corresponds to 0.37 kW (0.5 hp) with duty cycle HO.
Data
Intelligent Operator Panel IOP
Graphic display with bar-type diagrams, e.g. for status values such as pressure or flowrate.
User-friendly commissioning, diagnostics and local operator control using a large plain text display, clear menu navigation and application wizards.
Intelligent Operator Panel IOP Handheld
A handheld version of the IOP can be ordered for mobile use. In addition to the IOP, this includes a housing with rechargeable batteries, charging unit and RS232 connecting cable.
Basic Operator Panel BOP-2
Menu navigation and 2-line display permit fast and user-friendly commissioning of the inverter.
Simple basic commissioning by simultaneously displaying parameter and parameter value, as well as the option of filtering parameters.
Door mounting kit for IOP/BOP‑2
Using the optionally available door mounting kit, the IOP/BOP‑2 can be mounted in a control cabinet door with just a few manual operations (IP54/UL Type 12 degree of protection is achieved).
Push-through mounting
It is advisable to use an optionally available mounting
Memory card
The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced, the drive system is immediately ready for use again. The memory card can also be used to upgrade the firmware of the Control Unit.
Brake Relay
The Brake Relay allows the Power Module to be connected to an electromechanical motor brake. This allows the motor brake to be controlled directly from the Control Unit.
Safe Brake Relay
The Safe Brake Relay allows the Power Module to be safely connected to an electromechanical motor brake, allowing the brake to be directly and safely controlled from the CU250S‑2 Control Unit in accordance with IEC 61508 SIL 2 and EN ISO 13849‑1 PL d and Category 3.
PC inverter connection kit 2
For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool or SINAMICS Startdrive) has been installed.
Shield connection kit for Power Modules
The shield connection kit makes it easier to connect the shields of supply and control cables, provides mechanical strain relief and thus ensures optimum EMC performance. The shield connection kit is included in the scope of delivery of PM240‑2 Power Modules,
Shield connection kit for Control Units
The shield connection kit offers optimum shield connection and strain relief for all signal and communication cables. It includes a matching shield bonding plate and all of the necessary connecting and retaining elements for mounting.
De | Article No. |
---|---|
Intelligent Operator Panel IOP | |
| 6SL3255-0AA00-4JA1 |
| 6SL3255-0AA00-4JC1 |
Operator Panel IOP Handheld | 6SL3255-0AA00-4HA0 |
Operator Panel BOP‑2 | 6SL3255-0AA00-4CA1 |
Door mounting kit for IOP/BOP‑2 | 6SL3256-0AP00-0JA0 |
Push-through mounting | |
| |
| 6SL3260-6AA00-0DA0 |
| 6SL3260-6AB00-0DA0 |
| 6SL3260-6AC00-0DA0 |
Memory card | |
| 6SL3054-4AG00-2AA0 |
Brake Relay | 6SL3252-0BB00-0AA0 |
Safe Brake Relay | 6SL3252-0BB01-0AA0 |
PC inverter connection kit 2 | 6SL3255-0AA00-2CA0 |
Shield connection kits | |
| |
| Supplied with the Power Modules, available as a spare part |
| |
| 6SL3262-1AC00-0DA0 |
| 6SL3262-1AD00-0DA0 |
| 6SL3262-1AF00-0DA0 |
| |
| 6SL3264-1EA00-0FA0 |
| 6SL3264-1EA00-0HA0 |
| 6SL3264-1EA00-0HB0 |
| 6SL3264-1EA00-0LA0 |
STARTER commissioning tool 2) on DVD‑ROM | 6SL3072-0AA00-0AG0 |
SINAMICS Startdrive commissioning tool 3) on DVD‑ROM | 6SL3072-4DA02-0XG0 |
1) Approved only for CU230P‑2 HVAC and CU230P‑2 DP Control Units with firmware version V4.6 and higher.
2) The STARTER commissioning tool is also available on the Internet at http://www.siemens.com/starter
3) The SINAMICS Startdrive commissioning tool is also available on Internet at https://support.industry.siemens.com/cs/document/68034568
The following line-side power components are available for SINAMICS G120 standard inverters:
Line filters
With one of the additional line filters, the Power Module attains a higher radio interference class.
Line reactors
(only for PM240‑2 Power Modules,
Line reactors smooth the current drawn by the inverter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-
Note:
A DC
Recommended line-side power components
Furthermore, this is a recommendation for additional line-side components, such as fuses and circuit breakers (line-side components must be dimensioned in accordance with IEC standards).
Additional information about the line-side power components can be found in Catalogs LV 10, IC 10 and IC 10 AO as well as the Industry Mall.
The following DC
Braking resistors
(for PM240 and PM240‑2 Power Modules only)
Excess energy in the DC
Braking Module
(for PM240 Power Modules,
A Braking Module and the matching external braking resistor are required to bring drives with a PM240 Power Module,
The following load-side power components are available for the SINAMICS G120 standard inverters. This means that during operation with output reactors or sine-wave filters, longer, shielded motor cables are possible and the motor service life can be extended:
Output reactors
(not for PM240-2 Power Modules,
Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.
Sine-wave filters
(not for PM240‑2 Power Modules)
Sine-wave filters limit the rate of voltage rise (dv/dt) and the peak voltages on the motor winding. Similar to an output reactor, they enable the connection of longer motor cables.
Further selected supplementary products are available from Siemens Partners.
Please select “Drive Options” as the technology in the "Solution Partner Finder” :
http://www.siemens.com/automation/partnerfinder
Spare parts kit for Control Units
The spare parts kit contains small parts for all variants of the following SINAMICS G120 Control Units:
CU230P‑2
CU240E‑2
CU240E‑2 F
CU250S‑2
Shield connection kits for PM240‑2 Power Modules
A shield connection kit is supplied as standard with PM240‑2 Power Modules in
Replacement door for PM240 Power Modules,
A complete replacement door can be ordered for the PM240 Power Module,
Terminal cover kits for
The terminal cover kit includes a replacement cover for the connecting terminals. Terminal cover kits which are suitable for the PM240‑2 and PM250 Power Modules are available.
Replacement connectors for PM240‑2 Power Modules
A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the
Fan units for PM240‑2 Power Modules
The fans of PM240‑2 Power Modules are designed for extra long service life. For special requirements, replacement fans are available that can be exchanged quickly and easily.
Replacement fans for PM240 and PM250 Power Modules
The fans of PM240 and PM250 Power Modules are designed for extra long service life. Replacement fans can be ordered for special applications.
The following electronic configuring aids and engineering tools are available for the SINAMICS G120 standard inverters:
The interactive catalog CA 01 – the offline Industry Mall of Siemens on DVD‑ROM – contains over 100 000 products with approximately 5 million possible drive system product variants. The Drive Technology Configurator (DT Configurator) has been developed to facilitate selection of the correct motor and/or inverter from the wide spectrum of drives. It is integrated in Catalog CA 01 as an add-on on DVD‑ROM.
In addition, the DT Configurator can be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Industry Mall at the following address:
http://www.siemens.com/dt-configurator
The SIZER for Siemens Drives engineering tool makes it easy to engineer the SINAMICS drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER for Siemens Drives is designed to support configuring of the entire drive system.
You can find further information on the SIZER for Siemens Drives engineering tool in the chapter Engineering tools.
The SIZER for Siemens Drives engineering tool is available free on the Internet at
http://www.siemens.com/sizer
The STARTER commissioning tool allows menu-
You can find further information about the STARTER commissioning tool in the chapter Engineering tools.
Additional information about the STARTER commissioning tool is available on the Internet at
http://www.siemens.com/starter
SINAMICS Startdrive is a tool for configuring, commissioning, and diagnosing the SINAMICS family of drives and is integrated into the TIA Portal. SINAMICS Startdrive can be used to implement drive tasks with the SINAMICS G110M, SINAMICS G120, SINAMICS G120C, SINAMICS G120D and SINAMICS G120P inverter series. The commissioning tool has been optimized with regard to user friendliness and consistent use of the TIA Portal benefits of a common working environment for PLC, HMI and drives.
You can find further information on the SINAMICS Startdrive commissioning tool in the chapter Engineering tools.
The SINAMICS Startdrive commissioning tool is available free on the Internet at
http://www.siemens.com/startdrive
Drive ES is the engineering system that can be used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. Two software packages are available for SINAMICS – Drive ES Basic and Drive ES PCS.
You can find further information about the Drive ES engineering system in the chapter Engineering tools.
Additional information about the Drive ES engineering system is available on the Internet at
http://www.siemens.com/drive-es