General information
|
|
|
|
|
Product type designation
|
|
CPU 1215C DC/DC/DC
|
|
|
Firmware version
|
V4.2
|
V4.2
|
V4.2
|
|
Engineering with
|
|
|
|
|
|
STEP 7 V14 or higher
|
STEP 7 V14 or higher
|
STEP 7 V14 or higher
|
|
Supply voltage
|
|
|
|
|
Rated value (DC)
|
|
|
|
|
|
|
Yes
|
Yes
|
|
permissible range, lower limit (DC)
|
|
20.4 V
|
20.4 V
|
|
permissible range, upper limit (DC)
|
|
28.8 V
|
28.8 V
|
|
Rated value (AC)
|
|
|
|
|
|
Yes
|
|
|
|
|
Yes
|
|
|
|
permissible range, lower limit (AC)
|
85 V
|
|
|
|
permissible range, upper limit (AC)
|
265 V
|
|
|
|
Reverse polarity protection
|
|
Yes
|
Yes
|
|
Line frequency
|
|
|
|
|
|
47 Hz
|
|
|
|
|
63 Hz
|
|
|
|
Load voltage L+
|
|
|
|
|
|
|
24 V
|
24 V
|
|
|
|
20.4 V
|
20.4 V
|
|
|
|
28.8 V
|
28.8 V
|
|
Input current
|
|
|
|
|
Current consumption (rated value)
|
100 mA at 120 V AC; 50 mA at 240 V AC
|
500 mA; CPU only
|
500 mA; CPU only
|
|
Current consumption, max.
|
300 mA at 120 V AC; 150 mA at 240 V AC
|
1 500 mA; CPU with all expansion modules
|
1 500 mA; CPU with all expansion modules
|
|
Inrush current, max.
|
20 A; at 264 V
|
12 A; at 28.8 V DC
|
12 A; at 28.8 V DC
|
|
I²t
|
0.8 A²·s
|
0.5 A²·s
|
0.8 A²·s
|
|
Output current
|
|
|
|
|
for backplane bus (5 V DC), max.
|
1 600 mA; Max. 5 V DC for SM and CM
|
1 600 mA; Max. 5 V DC for SM and CM
|
1 600 mA; Max. 5 V DC for SM and CM
|
|
Encoder supply
|
|
|
|
|
24 V encoder supply
|
|
|
|
|
|
20.4 to 28.8V
|
L+ minus 4 V DC min.
|
L+ minus 4 V DC min.
|
|
Power loss
|
|
|
|
|
Power loss, typ.
|
14 W
|
12 W
|
12 W
|
|
Memory
|
|
|
|
|
Work memory
|
|
|
|
|
|
125 kbyte
|
125 kbyte
|
125 kbyte
|
|
|
No
|
No
|
No
|
|
Load memory
|
|
|
|
|
|
4 Mbyte
|
4 Mbyte
|
4 Mbyte
|
|
|
with SIMATIC memory card
|
with SIMATIC memory card
|
with SIMATIC memory card
|
|
Backup
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
CPU processing times
|
|
|
|
|
for bit operations, typ.
|
0.08 µs; / instruction
|
0.08 µs; / instruction
|
0.08 µs; / instruction
|
|
for word operations, typ.
|
1.7 µs; / instruction
|
1.7 µs; / instruction
|
1.7 µs; / instruction
|
|
for floating point arithmetic, typ.
|
2.3 µs; / instruction
|
2.3 µs; / instruction
|
2.3 µs; / instruction
|
|
CPU-blocks
|
|
|
|
|
Number of blocks (total)
|
DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
|
DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
|
DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
|
|
OB
|
|
|
|
|
|
Limited only by RAM for code
|
Limited only by RAM for code
|
Limited only by RAM for code
|
|
Data areas and their retentivity
|
|
|
|
|
Retentive data area (incl. timers, counters, flags), max.
|
10 kbyte
|
10 kbyte
|
10 kbyte
|
|
Flag
|
|
|
|
|
|
8 kbyte; Size of bit memory address area
|
8 kbyte; Size of bit memory address area
|
8 kbyte; Size of bit memory address area
|
|
Local data
|
|
|
|
|
|
16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB
|
16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB
|
16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB
|
|
Process image
|
|
|
|
|
|
1 kbyte
|
1 kbyte
|
1 kbyte
|
|
|
1 kbyte
|
1 kbyte
|
1 kbyte
|
|
Hardware configuration
|
|
|
|
|
Number of modules per system, max.
|
3 comm. modules, 1 signal board, 8 signal modules
|
3 comm. modules, 1 signal board, 8 signal modules
|
3 comm. modules, 1 signal board, 8 signal modules
|
|
Time of day
|
|
|
|
|
Clock
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
480 h; Typical
|
480 h; Typical
|
480 h; Typical
|
|
|
±60 s/month at 25 °C
|
±60 s/month at 25 °C
|
±60 s/month at 25 °C
|
|
Digital inputs
|
|
|
|
|
Number of digital inputs
|
14; Integrated
|
14; Integrated
|
14; Integrated
|
|
|
6; HSC (High Speed Counting)
|
6; HSC (High Speed Counting)
|
6; HSC (High Speed Counting)
|
|
Source/sink input
|
Yes
|
Yes
|
Yes
|
|
Number of simultaneously controllable inputs
|
|
|
|
|
all mounting positions
|
|
|
|
|
|
14
|
14
|
14
|
|
Input voltage
|
|
|
|
|
|
24 V
|
24 V
|
24 V
|
|
|
5 V DC at 1 mA
|
5 V DC at 1 mA
|
5 V DC at 1 mA
|
|
|
15 V DC at 2.5 mA
|
15 V DC at 2.5 mA
|
15 V DC at 2.5 mA
|
|
Input delay (for rated value of input voltage)
|
|
|
|
|
for standard inputs
|
|
|
|
|
|
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four
|
0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four
|
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four
|
|
|
0.2 ms
|
0.2 ms
|
0.2 ms
|
|
|
12.8 ms
|
12.8 ms
|
12.8 ms
|
|
for interrupt inputs
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
for counter/technological functions
|
|
|
|
|
|
Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz
|
Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz
|
Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz
|
|
Cable length
|
|
|
|
|
|
500 m; 50 m for technological functions
|
500 m; 50 m for technological functions
|
500 m; 50 m for technological functions
|
|
|
300 m; For technological functions: No
|
300 m; For technological functions: No
|
300 m; For technological functions: No
|
|
Digital outputs
|
|
|
|
|
Number of digital outputs
|
10; Relays
|
10
|
10; Relays
|
|
|
|
4; 100 kHz Pulse Train Output
|
|
|
Limitation of inductive shutdown voltage to
|
|
L+ (-48 V)
|
|
|
Switching capacity of the outputs
|
|
|
|
|
|
2 A
|
0.5 A
|
2 A
|
|
|
30 W with DC, 200 W with AC
|
5 W
|
30 W with DC, 200 W with AC
|
|
Output voltage
|
|
|
|
|
|
|
0.1 V; with 10 kOhm load
|
|
|
|
|
20 V
|
|
|
Output current
|
|
|
|
|
|
|
0.5 A
|
|
|
|
|
0.1 mA
|
|
|
Output delay with resistive load
|
|
|
|
|
|
10 ms; max.
|
1 µs
|
10 ms; max.
|
|
|
10 ms; max.
|
5 µs
|
10 ms; max.
|
|
Switching frequency
|
|
|
|
|
|
|
100 kHz
|
|
|
Relay outputs
|
|
|
|
|
|
mechanically 10 million, at rated load voltage 100 000
|
|
mechanically 10 million, at rated load voltage 100 000
|
|
Cable length
|
|
|
|
|
|
500 m
|
500 m
|
500 m
|
|
|
150 m
|
150 m
|
150 m
|
|
Analog inputs
|
|
|
|
|
Number of analog inputs
|
2
|
2
|
2
|
|
Input ranges
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Input ranges (rated values), voltages
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
≥100k ohms
|
≥100k ohms
|
≥100k ohms
|
|
Cable length
|
|
|
|
|
|
100 m; twisted and shielded
|
100 m; twisted and shielded
|
100 m; twisted and shielded
|
|
Analog outputs
|
|
|
|
|
Number of analog outputs
|
2
|
2
|
2
|
|
Output ranges, current
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Analog value generation for the inputs
|
|
|
|
|
Integration and conversion time/resolution per channel
|
|
|
|
|
|
10 bit
|
10 bit
|
10 bit
|
|
|
Yes
|
Yes
|
Yes
|
|
|
625 µs
|
625 µs
|
625 µs
|
|
Analog value generation for the outputs
|
|
|
|
|
Integration and conversion time/resolution per channel
|
|
|
|
|
|
|
10 bit
|
10 bit
|
|
Encoder
|
|
|
|
|
Connectable encoders
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
1. Interface
|
|
|
|
|
Interface type
|
PROFINET
|
PROFINET
|
PROFINET
|
|
Physics
|
Ethernet
|
Ethernet
|
Ethernet
|
|
Isolated
|
Yes
|
Yes
|
Yes
|
|
automatic detection of transmission rate
|
Yes
|
Yes
|
Yes
|
|
Autonegotiation
|
Yes
|
Yes
|
Yes
|
|
Autocrossing
|
Yes
|
Yes
|
Yes
|
|
Interface types
|
|
|
|
|
|
2
|
2
|
2
|
|
|
Yes
|
Yes
|
Yes
|
|
Functionality
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes; as MRP client
|
Yes; as MRP client
|
Yes; as MRP client
|
|
PROFINET IO Controller
|
|
|
|
|
|
100 Mbit/s
|
100 Mbit/s
|
100 Mbit/s
|
|
Services
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
No
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
|
|
No
|
No
|
No
|
|
|
Yes; as MRP client
|
Yes; as MRP client
|
Yes; as MRP client
|
|
|
No
|
No
|
No
|
|
|
No
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
|
|
16
|
16
|
16
|
|
|
16
|
16
|
16
|
|
|
16
|
16
|
16
|
|
|
16
|
16
|
16
|
|
|
Yes
|
Yes
|
Yes
|
|
|
8
|
8
|
8
|
|
|
The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
|
The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
|
The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
|
|
PROFINET IO Device
|
|
|
|
|
Services
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
No
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
|
|
No
|
No
|
No
|
|
|
Yes; as MRP client
|
Yes; as MRP client
|
Yes; as MRP client
|
|
|
No
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
2
|
2
|
2
|
|
Protocols
|
|
|
|
|
Supports protocol for PROFINET IO
|
Yes
|
Yes
|
Yes
|
|
PROFIBUS
|
Yes; CM 1243-5 required
|
Yes; CM 1243-5 required
|
Yes; CM 1243-5 required
|
|
AS-Interface
|
Yes; CM 1243-2 required
|
Yes; CM 1243-2 required
|
Yes; CM 1243-2 required
|
|
Protocols (Ethernet)
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
No
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Open IE communication
|
|
|
|
|
|
|
|
|
|
|
8 kbyte
|
8 kbyte
|
8 kbyte
|
|
|
Yes
|
Yes
|
Yes
|
|
|
8 kbyte
|
8 kbyte
|
8 kbyte
|
|
|
|
|
|
|
|
1 472 byte
|
1 472 byte
|
1 472 byte
|
|
Further protocols
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Communication functions
|
|
|
|
|
S7 communication
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
See online help (S7 communication, user data size)
|
See online help (S7 communication, user data size)
|
See online help (S7 communication, user data size)
|
|
Open IE communication
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Web server
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Number of connections
|
|
|
|
|
|
16; dynamically
|
16; dynamically
|
16; dynamically
|
|
Test commissioning functions
|
|
|
|
|
Status/control
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
|
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
|
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
|
|
Forcing
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Diagnostic buffer
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Traces
|
|
|
|
|
|
2
|
2
|
2
|
|
|
512 kbyte
|
512 kbyte
|
512 kbyte
|
|
Interrupts/diagnostics/status information
|
|
|
|
|
Diagnostics indication LED
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Integrated Functions
|
|
|
|
|
Number of counters
|
6
|
6
|
6
|
|
Counting frequency (counter) max.
|
100 kHz
|
100 kHz
|
100 kHz
|
|
Frequency meter
|
Yes
|
Yes
|
Yes
|
|
controlled positioning
|
Yes
|
Yes
|
Yes
|
|
Number of position-controlled positioning axes, max.
|
8
|
8
|
8
|
|
Number of positioning axes via pulse-direction interface
|
Up to 4 with SB 1222
|
4; With integrated outputs
|
Up to 4 with SB 1222
|
|
PID controller
|
Yes
|
Yes
|
Yes
|
|
Number of alarm inputs
|
4
|
4
|
4
|
|
Number of pulse outputs
|
|
4
|
|
|
Limit frequency (pulse)
|
|
100 kHz
|
|
|
Potential separation
|
|
|
|
|
Potential separation digital inputs
|
|
|
|
|
|
500V AC for 1 minute
|
No
|
500V AC for 1 minute
|
|
|
1
|
1
|
1
|
|
Potential separation digital outputs
|
|
|
|
|
|
Relays
|
Yes
|
Relays
|
|
|
No
|
No
|
No
|
|
|
2
|
1
|
2
|
|
EMC
|
|
|
|
|
Interference immunity against discharge of static electricity
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
8 kV
|
8 kV
|
8 kV
|
|
|
6 kV
|
6 kV
|
6 kV
|
|
Interference immunity to cable-borne interference
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Interference immunity against voltage surge
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Interference immunity against conducted variable disturbance induced by high-frequency fields
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Emission of radio interference acc. to EN 55 011
|
|
|
|
|
|
Yes; Group 1
|
Yes; Group 1
|
Yes; Group 1
|
|
|
Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
|
Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
|
Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
|
|
Degree and class of protection
|
|
|
|
|
Degree of protection acc. to EN 60529
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Standards, approvals, certificates
|
|
|
|
|
CE mark
|
Yes
|
Yes
|
Yes
|
|
UL approval
|
Yes
|
Yes
|
Yes
|
|
cULus
|
Yes
|
Yes
|
Yes
|
|
FM approval
|
Yes
|
Yes
|
Yes
|
|
RCM (formerly C-TICK)
|
Yes
|
Yes
|
Yes
|
|
KC approval
|
Yes
|
Yes
|
Yes
|
|
Marine approval
|
Yes
|
Yes
|
Yes
|
|
Ambient conditions
|
|
|
|
|
Free fall
|
|
|
|
|
|
0.3 m; five times, in product package
|
0.3 m; five times, in product package
|
0.3 m; five times, in product package
|
|
Ambient temperature during operation
|
|
|
|
|
|
-20 °C
|
-20 °C
|
-20 °C
|
|
|
60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical
|
60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical
|
60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical
|
|
|
-20 °C
|
-20 °C
|
-20 °C
|
|
|
60 °C
|
60 °C
|
60 °C
|
|
|
-20 °C
|
-20 °C
|
-20 °C
|
|
|
50 °C
|
50 °C
|
50 °C
|
|
Ambient temperature during storage/transportation
|
|
|
|
|
|
-40 °C
|
-40 °C
|
-40 °C
|
|
|
70 °C
|
70 °C
|
70 °C
|
|
Air pressure acc. to IEC 60068-2-13
|
|
|
|
|
|
795 hPa
|
795 hPa
|
795 hPa
|
|
|
1 080 hPa
|
1 080 hPa
|
1 080 hPa
|
|
|
660 hPa
|
660 hPa
|
660 hPa
|
|
|
1 080 hPa
|
1 080 hPa
|
1 080 hPa
|
|
|
-1000 to 2000 m
|
-1000 to 2000 m
|
-1000 to 2000 m
|
|
Relative humidity
|
|
|
|
|
|
95 %; no condensation
|
95 %; no condensation
|
95 %; no condensation
|
|
Vibrations
|
|
|
|
|
|
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
|
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
|
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
|
|
|
Yes
|
Yes
|
Yes
|
|
Shock test
|
|
|
|
|
|
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
|
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
|
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
|
|
Pollutant concentrations
|
|
|
|
|
|
S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
|
S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
|
S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free
|
|
Programming
|
|
|
|
|
Programming language
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Know-how protection
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Access protection
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Yes
|
Yes
|
Yes
|
|
Cycle time monitoring
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
Dimensions
|
|
|
|
|
Width
|
130 mm
|
130 mm
|
130 mm
|
|
Height
|
100 mm
|
100 mm
|
100 mm
|
|
Depth
|
75 mm
|
75 mm
|
75 mm
|
|
Weights
|
|
|
|
|
Weight, approx.
|
550 g
|